The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A rigidity penalty term for nonrigid registration
Abstract
Medical images that are to be registered for clinical application often contain both structures that deform and ones that remain rigid. Nonrigid registration algorithms that do not model properties of different tissue types may result in deformations of rigid structures. In this article a local rigidity penalty term is proposed which is included in the registration function in order to penalize the deformation of rigid objects. This term can be used for any representation of the deformation field capable of modelling locally rigid transformations. By using a B‐spline representation of the deformation field, a fast algorithm can be devised. The proposed method is compared with an unconstrained nonrigid registration algorithm. It is evaluated on clinical three‐dimensional CT follow‐up data of the thorax and on two‐dimensional DSA image sequences. The results show that nonrigid registration using the proposed rigidity penalty term is capable of nonrigidly aligning images, while keeping user‐defined structures locally rigid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Cited by
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Self-citationDeformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“[239] imposed rigidity by introducing three conditions.”
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
A deep learning framework for unsupervised affine and deformable image registration
de Vos, B. D., Berendsen, F. F., Viergever, M. A., Sokooti, H., Staring, M., & Išgum, I. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.11.010 · Cited by 818
“Additional regularization during training might enforce diffeomorphism (Staring et al., 2007), with no extra cost to execution time.”
BackgroundSelf-citationFast parallel image registration on CPU and GPU for diagnostic classification of Alzheimer's disease
Shamonin, D. (2013) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2013.00050 · Cited by 586
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
Metadata
- Authors
- Staring, M., Klein, S., & Pluim, J. P. W.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2007-10-10
- Volume
- 34
- Issue
- 11
- Pages
- 4098-4108
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1977670780
- Cited by
- 171
- References
- 2
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.