The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effects of MRI acquisition parameter variations and protocol heterogeneity on the results of texture analysis and pattern discrimination: An application‐oriented study
Abstract
MRI texture features are generally considered to be sensitive to variations in signal‐to‐noise ratio and spatial resolution, which represents an obstacle for the widespread clinical application of texture‐based pattern discrimination with MRI. This study investigates the sensitivity of texture features of different categories (co‐occurrence matrix, run‐length matrix, absolute gradient, autoregressive model, and wavelet transform) to variations in the number of acquisitions (NAs), repetition time (TR), echo time (TE), and sampling bandwidth (SBW) at different spatial resolutions. Special emphasis was placed on the influence of MRI protocol heterogeneity and implications for the results of pattern discrimination. Experiments were performed using two polystyrene spheres and agar gel phantoms with different nodular patterns. T2‐weighted multislice multiecho images were obtained using a 3.0 T scanner equipped with a microimaging gradient insert coil. Linear discriminant analysis and k nearest neighbor classification were used for texture‐based pattern discrimination. Results show that texture features of all categories are increasingly sensitive to acquisition parameter variations with increasing spatial resolution. Nevertheless, as long as the spatial resolution is sufficiently high, variations in NA, TR, TE, and SBW have little effect on the results of pattern discrimination. Texture features derived from the co‐occurrence matrix are superior to features of other categories because they enable discrimination of different patterns close to the resolution limits for the smallest structures of physical texture even for datasets that are heterogeneous with regard to different acquisition parameters, including spatial resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Cited by
Radiomics: the facts and the challenges of image analysis
Rizzo, S., Botta, F., Raimondi, S., Origgi, D., Fanciullo, C., Morganti, A. G., & Bellomi, M. (2018) · European Radiology Experimental · doi:10.1186/s41747-018-0068-z · Cited by 1,054
Liu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice?
Davnall, F., Yip, C. S. P., Ljungqvist, G., Selmi, M., Ng, F., Sanghera, B., Ganeshan, B., Miles, K. A., Cook, G. J., & Goh, V. (2012) · Insights into Imaging · doi:10.1007/s13244-012-0196-6 · Cited by 878
Zacharaki, E. I., Wang, S., Chawla, S., Soo Yoo, D., Wolf, R., Melhem, E. R., & Davatzikos, C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22147 · Cited by 855
Radiomics in breast cancer classification and prediction
Conti, A., Duggento, A., Indovina, I., Guerrisi, M., & Toschi, N. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.04.002 · Cited by 386
Metadata
- Authors
- Mayerhoefer, M. E., Szomolanyi, P., Jirak, D., Materka, A., & Trattnig, S.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-03-18
- Volume
- 36
- Issue
- 4
- Pages
- 1236-1243
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2040454936
- Cited by
- 225
- References
- 1
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.