On the speckle‐free nature of photoacoustic tomography
Open accessThe DOI matches its Crossref record.
Abstract
Purpose: A long‐standing conundrum is why photoacoustic tomography (PAT) possesses the unique ability to produce images devoid of speckle artifacts while all other coherent imaging technologies do not. Methods: In this paper, we explain the inherent mechanism that suppresses speckle in PAT, and the analysis was validated by simulations based on an experimental PAT system. Results: We found that the speckle‐free feature of PAT results directly from the optical absorption contrast. Conclusions: All optical absorbers expand on laser excitation, and therefore all initial photoacoustic pressure rises are positive, which engenders strong correlations among the photoacoustic waves from the absorbers. As a result, prominent boundaries always build up in photoacoustic images and suppress the interior speckle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Self-citationMultiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Self-citationThe emerging role of photoacoustic imaging in clinical oncology
Lin, L., & Wang, L. V. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00615-3 · Cited by 469
Self-citationStructural and functional photoacoustic molecular tomography aided by emerging contrast agents
Nie, L., & Chen, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00086b · Cited by 383
Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system
Kim, C., Erpelding, T. N., Jankovic, L., Pashley, M. D., & Wang, L. V. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000278 · Cited by 289
Self-citationNanoparticles for photoacoustic imaging
Yang, X., Stein, E. W., Ashkenazi, S., & Wang, L. V. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.42 · Cited by 265
Self-citationPhotoacoustic tomography: fundamentals, advances and prospects
Yao, J., & Wang, L. V. (2011) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.443 · Cited by 226
Self-citationClinical photoacoustic imaging platforms
Choi, W., Park, E.-Y., Jeon, S., & Kim, C. (2018) · Biomedical Engineering Letters · doi:10.1007/s13534-018-0062-7 · Cited by 203
“Other advantages of PAI include: PA images are more sensitive to small blood vessels than US Doppler images [29, 38], PA image has no speckle artifacts [39], and PAI system is Wonseok Choi, Eun-Yeong Park and Seungwan Jeon have contributed equally to this work.”
BackgroundCompressed sensing in photoacoustic tomography in vivo
Guo, Z., Li, C., Song, L., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3381187 · Cited by 172
“Unlike ultrasound imaging and all other coherent imaging technologies, PAT is devoid of speckle artifacts and sensitive to boundaries because of its optical absorption contrast.(31) Therefore, computing the finite difference FD of PAT images in the spatial domain sometimes directly results in a sparse representation.”
BackgroundSelf-citationRecent advances in photoacoustic contrast agents for in vivo imaging
Upputuri, P. K., & Pramanik, M. (2020) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1618 · Cited by 168
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Toward wearable healthcare: a miniaturized 3d imager with coherent frequency-domain photoacoustics
Liu, S., Tang, K., Feng, X., Jin, H., Gao, F., & Zheng, Y. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2940243 · Cited by 25
Metadata
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.