Mass preserving nonrigid registration of CT lung images using cubic B‐spline
Open accessAbstract
The authors propose a nonrigid image registration approach to align two computed‐tomography (CT)‐derived lung datasets acquired during breath‐holds at two inspiratory levels when the image distortion between the two volumes is large. The goal is to derive a three‐dimensional warping function that can be used in association with computational fluid dynamics studies. In contrast to the sum of squared intensity difference (SSD), a new similarity criterion, the sum of squared tissue volume difference (SSTVD), is introduced to take into account changes in reconstructed Hounsfield units (scaled attenuation coefficient, HU) with inflation. This new criterion aims to minimize the local tissue volume difference within the lungs between matched regions, thus preserving the tissue mass of the lungs if the tissue density is assumed to be relatively constant. The local tissue volume difference is contributed by two factors: Change in the regional volume due to the deformation and change in the fractional tissue content in a region due to inflation. The change in the regional volume is calculated from the Jacobian value derived from the warping function and the change in the fractional tissue content is estimated from reconstructed HU based on quantitative CT measures. A composite of multilevel B‐spline is adopted to deform images and a sufficient condition is imposed to ensure a one‐to‐one mapping even for a registration pair with large volume difference. Parameters of the transformation model are optimized by a limited‐memory quasi‐Newton minimization approach in a multiresolution framework. To evaluate the effectiveness of the new similarity measure, the authors performed registrations for six lung volume pairs. Over 100 annotated landmarks located at vessel bifurcations were generated using a semiautomatic system. The results show that the SSTVD method yields smaller average landmark errors than the SSD method across all six registration pairs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Cited by
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2246577 · Cited by 311
Lambert, A. R., O'shaughnessy, P. T., Tawhai, M. H., Hoffman, E. A., & Lin, C.-L. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2010.517578 · Cited by 175
Self-citationLung imaging in COPD and asthma
Tanabe, N., Nakagawa, H., Sakao, S., Ohno, Y., Shimizu, K., Nakamura, H., Hanaoka, M., Nakano, Y., & Hirai, T. (2024) · Respiratory Investigation · doi:10.1016/j.resinv.2024.08.014 · Cited by 21
Metadata
- Authors
- Yin, Y., Hoffman, E. A., & Lin, C.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-08-17
- Volume
- 36
- Issue
- 9Part1
- Pages
- 4213-4222
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2020133147
- Cited by
- 207
- References
- 1
- FWCI
- 17.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass preserving nonrigid registration of CT lung images using cubic B‐spline. https://app.cochat.ai/papers/10.1118/1.3193526
- The paper
- Yin, Y., Hoffman, E. A., & Lin, C. (2009). Mass preserving nonrigid registration of CT lung images using cubic B‐spline. Medical Physics. https://doi.org/10.1118/1.3193526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.