Mass preserving nonrigid registration of CT lung images using cubic B‐spline
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The authors propose a nonrigid image registration approach to align two computed‐tomography (CT)‐derived lung datasets acquired during breath‐holds at two inspiratory levels when the image distortion between the two volumes is large. The goal is to derive a three‐dimensional warping function that can be used in association with computational fluid dynamics studies. In contrast to the sum of squared intensity difference (SSD), a new similarity criterion, the sum of squared tissue volume difference (SSTVD), is introduced to take into account changes in reconstructed Hounsfield units (scaled attenuation coefficient, HU) with inflation. This new criterion aims to minimize the local tissue volume difference within the lungs between matched regions, thus preserving the tissue mass of the lungs if the tissue density is assumed to be relatively constant. The local tissue volume difference is contributed by two factors: Change in the regional volume due to the deformation and change in the fractional tissue content in a region due to inflation. The change in the regional volume is calculated from the Jacobian value derived from the warping function and the change in the fractional tissue content is estimated from reconstructed HU based on quantitative CT measures. A composite of multilevel B‐spline is adopted to deform images and a sufficient condition is imposed to ensure a one‐to‐one mapping even for a registration pair with large volume difference. Parameters of the transformation model are optimized by a limited‐memory quasi‐Newton minimization approach in a multiresolution framework. To evaluate the effectiveness of the new similarity measure, the authors performed registrations for six lung volume pairs. Over 100 annotated landmarks located at vessel bifurcations were generated using a semiautomatic system. The results show that the SSTVD method yields smaller average landmark errors than the SSD method across all six registration pairs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Limited Memory Algorithm for Bound Constrained Optimization
Byrd, R. H., Lu, P., Nocedal, J., & Zhu, C. (1995) · SIAM Journal on Scientific Computing · doi:10.1137/0916069 · Cited by 6,221 · cited 2×
“34 are used here.”
MethodNonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890 · cited 1×
“In addition, normalized correlation 9,18 and mutual information (cid:1) MI (cid:2) 19–21 have been used in registering CT lung images.”
MethodScattered data interpolation with multilevel B-splines
Lee, S., Wolberg, G., & Shin, S. Y. (1997) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.620490 · Cited by 1,046
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
Hu, S., Hoffman, E. A., & Reinhardt, J. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929615 · Cited by 940
Self-citationPET-CT image registration in the chest using free-form deformations
Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., & Eubank, W. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809072 · Cited by 871 · cited 1×
“33, a limited-memory quasi-Newton minimization method with bounds on the variables (cid:1) L-BFGS-B (cid:2) 34 is adopted considering its two advantages.”
MethodNon-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Christensen, G. E., & Johnson, H. J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932742 · Cited by 636 · cited 1×
“Christensen and Johnson 24 used the Jacobian value to check for folding of the deformation.”
MethodFast parametric elastic image registration
Kybic, J., & Unser, M. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.813139 · Cited by 477 · cited 1×
“26,27 Compared to other transformation models, B-spline-based FFD is locally controlled and, thus, it is computationally efficient even for a large number of con-trol nodes.”
BackgroundRohlfing, T., Maurer, C. R., Bluemke, D. A., & Jacobs, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.814791 · Cited by 445
Cited by
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2246577 · Cited by 311
Hueper, K., Vogel-Claussen, J., Parikh, M. A., Austin, J. H. M., Bluemke, D. A., Carr, J., Choi, J., Goldstein, T. A., Gomes, A. S., Hoffman, E. A., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201411-2120oc · Cited by 179
Self-citationLambert, A. R., O'shaughnessy, P. T., Tawhai, M. H., Hoffman, E. A., & Lin, C.-L. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2010.517578 · Cited by 175
“The modeling of lung movement could be achieved by image registration (Lin et al. 2009; Tawhai et al. 2009; Yin et al. 2009a,b; Yin et al. 2010).”
BackgroundSelf-citationLung imaging in COPD and asthma
Tanabe, N., Nakagawa, H., Sakao, S., Ohno, Y., Shimizu, K., Nakamura, H., Hanaoka, M., Nakano, Y., & Hirai, T. (2024) · Respiratory Investigation · doi:10.1016/j.resinv.2024.08.014 · Cited by 21
Metadata
- Authors
- Yin, Y., Hoffman, E. A., & Lin, C.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-08-17
- Volume
- 36
- Issue
- 9Part1
- Pages
- 4213-4222
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2020133147
- Cited by
- 207
- References
- 40
- FWCI
- 17.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.