Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Automatic selection of tube potential for radiation dose reduction in CT: A general strategy

Yu, Lifeng, Li, Hua, Fletcher, Joel G., McCollough, Cynthia H.·2010·Medical Physics

Abstract

Purpose: To optimize radiation dose efficiency in CT while maintaining image quality, it is important to select the optimal tube potential. The selection of optimal tube potential, however, is highly dependent on patient size and diagnostic task. The purpose of this work was to develop a general strategy that allows for automatic tube potential selection for each individual patient and each diagnostic task. Methods: The authors propose a general strategy that allows automatic adaptation of the tube potential as a function of patient size and diagnostic task, using a novel index of image quality, “iodine contrast to noise ratio with a noise constraint (iCNR_NC),” to characterize the different image quality requirements by various clinical applications. The relative dose factor (RDF) at each tube potential to achieve a target image quality was then determined as a function of patient size and the noise constraint parameter. A workflow was developed to automatically identify the optimal tube potential that is both dose efficient and practically feasible, incorporating patient size and diagnostic task. An experimental study using a series of semianthropomorphic thoracic phantoms was used to demonstrate how the proposed general strategy can be implemented and how the radiation dose reduction achievable by the tube potential selection depends on phantom sizes and noise constraint parameters. Results: The proposed strategy provides a flexible and quantitative way to select the optimal tube potential based on the patient size and diagnostic task. The noise constraint parameter can be adapted for different clinical applications. For example, for noncontrast routine exams; for contrast‐enhanced routine exams; and for CT angiography. For the five thoracic phantoms in the experiment, when , the optimal tube potentials were 80, 100, 100, 120, 120, respectively. The corresponding RDFs (relative to 120 kV) were 78.0%, 90.9%, 95.2%, 100%, and 100%. When , the optimal tube potentials were 80, 80, 80, 100, 100, respectively, with corresponding RDFs of 34.7%, 44.7%, 54.7%, 60.8%, and 89.5%. Conclusions: A general strategy to automatically select the most dose efficient tube potential for CT exams was developed that takes into account patient size and diagnostic task. Dependent on the patient size and the selection of noise constraint parameter for different diagnostic tasks, the dose reduction at each tube potential, quantified explicitly with the RDF, varies significantly.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3264614

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 230

Metadata

Authors
Yu, L., Li, H., Fletcher, J. G., & McCollough, C. H.
Venue
Medical Physics
Publisher
Wiley
Published
2009-12-10
Volume
37
Issue
1
Pages
234-243
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2093496376
Cited by
230
References
1
FWCI
10.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic selection of tube potential for radiation dose reduction in CT: A general strategy. https://app.cochat.ai/papers/10.1118/1.3264614
The paper
Yu, L., Li, H., Fletcher, J. G., & McCollough, C. H. (2010). Automatic selection of tube potential for radiation dose reduction in CT: A general strategy. Medical Physics. https://doi.org/10.1118/1.3264614

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.