GPUMCD: A new GPU‐oriented Monte Carlo dose calculation platform
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Purpose: Monte Carlo methods are considered as the gold standard for dosimetric computations in radiotherapy. Their execution time is, however, still an obstacle to the routine use of Monte Carlo packages in a clinical setting. To address this problem, a completely new, and designed from the ground up for the GPU, Monte Carlo dose calculation package for voxelized geometries is proposed:GPUMCD. Method: GPUMCD implements a coupled photon‐electron Monte Carlo simulation for energies in the range of 0.01–20 MeV. An analog simulation of photon interactions is used and a class II condensed history method has been implemented for the simulation of electrons. A new GPU random number generator, some divergence reduction methods, as well as other optimization strategies are also described.GPUMCD was run on a NVIDIA GTX480, while single threaded implementations of EGSnrc and DPM were run on an Intel Core i7 860. Results: Dosimetric results obtained with GPUMCD were compared to EGSnrc. In all but one test case, 98% or more of all significant voxels passed the gamma criteria of 2%‐2 mm. In terms of execution speed and efficiency,GPUMCD is more than 900 times faster than EGSnrc and more than 200 times faster than DPM, a Monte Carlo package aiming fast executions. Absolute execution times of less than 0.3 s are found for the simulation of 1M electrons and 4M photons in water for monoenergetic beams of 15 MeV, including GPU‐CPU memory transfers. Conclusion: GPUMCD, a new GPU‐oriented Monte Carlo dose calculation platform, has been compared to EGSnrc and DPM in terms of dosimetric results and execution speed. Its accuracy and speed make it an interesting solution for full Monte Carlo dose calculation in radiation oncology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
General purpose molecular dynamics simulations fully implemented on graphics processing units
Anderson, J. A., Lorenz, C. D., & Travesset, A. (2008) · Journal of Computational Physics · doi:10.1016/j.jcp.2008.01.047 · Cited by 1,481
Klein, O., & Nishina, Y. (1929) · Zeitschrift für Physik · doi:10.1007/bf01366453 · Cited by 1,445
The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport
Kawrakow, I., Mainegra‐Hing, E., & Tessier, F. (2016) · NPARC · Cited by 1,137
TestU01: A C library for empirical testing of random number generators
L'Ecuyer, P., & Simard, R. (2007) · ACM Transactions on Mathematical Software · doi:10.1145/1268776.1268777 · Cited by 1,014
Nelson, W., Hirayama, H., & Rogers, D. (1985) · doi:10.2172/1453993 · Cited by 971
Kawrakow, I. (2000) · Medical Physics · doi:10.1118/1.598917 · Cited by 945
Alerstam, E., Svensson, T., & Andersson-Engels, S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3041496 · Cited by 407
A New Class of Random Number Generators
Marsaglia, G., & Zaman, A. (1991) · The Annals of Applied Probability · doi:10.1214/aoap/1177005878 · Cited by 370 · cited 3×
“Medical Physics, 36(6):1998–2005, 2009.614 [41] George Marsaglia and Arif Zaman.”
MethodInfluentialBadal, A., & Badano, A. (2009) · Medical Physics · doi:10.1118/1.3231824 · Cited by 358
GPU accelerated Monte Carlo simulation of the 2D and 3D Ising model
Preis, T., Virnau, P., Paul, W., & Schneider, J. J. (2009) · Journal of Computational Physics · doi:10.1016/j.jcp.2009.03.018 · Cited by 330
Cited by
GPU computing in medical physics: A review
Pratx, G., & Xing, L. (2011) · Medical Physics · doi:10.1118/1.3578605 · Cited by 300
GPU-based fast Monte Carlo simulation for radiotherapy dose calculation
Jia, X., Gu, X., Graves, Y. J., Folkerts, M., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/22/002 · Cited by 185
GPU-based fast Monte Carlo dose calculation for proton therapy
Jia, X., Schümann, J., Paganetti, H., & Jiang, S. B. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7783 · Cited by 177
“In particular, a set of MC packages has been successfully developed for mega-voltage photon dose calculations and high acceleration factors have been reported (Jia et al 2010a, 2011, Hissoiny et al 2011, Jahnke et al 2012).”
BackgroundMethod
Metadata
- Authors
- Hissoiny, S., Ozell, B., Bouchard, H., & Després, P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2011-01-13
- Volume
- 38
- Issue
- 2
- Pages
- 754-764
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2000836605
- Cited by
- 219
- References
- 17
- FWCI
- 16.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: GPUMCD: A new GPU‐oriented Monte Carlo dose calculation platform. https://app.cochat.ai/papers/10.1118/1.3539725
- The paper
- Hissoiny, S., Ozell, B., Bouchard, H., & Després, P. (2011). GPUMCD: A new GPU‐oriented Monte Carlo dose calculation platform. Medical Physics. https://doi.org/10.1118/1.3539725
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.