The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Parallel computing with graphics processing units for high-speed Monte Carlo simulation of photon migration
Open accessAbstract
General-purpose computing on graphics processing units (GPGPU) is shown to dramatically increase the speed of Monte Carlo simulations of photon migration. In a standard simulation of time-resolved photon migration in a semi-infinite geometry, the proposed methodology executed on a low-cost graphics processing unit (GPU) is a factor 1000 faster than simulation performed on a single standard processor. In addition, we address important technical aspects of GPU-based simulations of photon migration. The technique is expected to become a standard method in Monte Carlo simulations of photon migration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mersenne twister: a 623-dimensionally equidistributed uniform pseudo-random number generator
Matsumoto, M., & Nishimura, T. (1998) · ACM Transactions on Modeling and Computer Simulation · doi:10.1145/272991.272995 · Cited by 5,780
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Flock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
In vivo local determination of tissue optical properties: applications to human brain
Bevilacqua, F., Piguet, D., Marquet, P., Gross, J. D., Tromberg, B. J., & Depeursinge, C. (1999) · Applied Optics · doi:10.1364/ao.38.004939 · Cited by 456
Palmer, G. M., & Ramanujam, N. (2006) · Applied Optics · doi:10.1364/ao.45.001062 · Cited by 323
Condensed Monte Carlo simulations for the description of light transport
Graaff, R., Koelink, M. H., de Mul, F. F. M., Zijlstra, W. G., Dassel, A. C. M., & Aarnoudse, J. G. (1993) · Applied Optics · doi:10.1364/ao.32.000426 · Cited by 184
Determination of the optical properties of turbid media from a single Monte Carlo simulation
Kienle, A., & Patterson, M. S. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/10/026 · Cited by 183
Cited by
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Time domain functional NIRS imaging for human brain mapping
Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.106 · Cited by 466
Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates
Fang, Q. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000165 · Cited by 384
Badal, A., & Badano, A. (2009) · Medical Physics · doi:10.1118/1.3231824 · Cited by 358
Metadata
- Authors
- Alerstam, E., Svensson, T., & Andersson-Engels, S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2008
- Volume
- 13
- Issue
- 6
- Pages
- 060504
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2095734710
- Cited by
- 407
- References
- 18
- FWCI
- 15.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parallel computing with graphics processing units for high-speed Monte Carlo simulation of photon migration. https://app.cochat.ai/papers/10.1117/1.3041496
- The paper
- Alerstam, E., Svensson, T., & Andersson-Engels, S. (2008). Parallel computing with graphics processing units for high-speed Monte Carlo simulation of photon migration. Journal of Biomedical Optics. https://doi.org/10.1117/1.3041496
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.