CoChat

Elastic registration of multimodal prostate MRI and histology via multiattribute combined mutual information

Open access
Chappelow, Jonathan, Bloch, B. Nicolas, Rofsky, Neil, Genega, Elizabeth, Lenkinski, Robert, DeWolf, William, Madabhushi, Anant · 2011 · Medical Physics
Cited by 115

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Purpose: By performing registration of preoperative multiprotocol in vivo magnetic resonance (MR) images of the prostate with corresponding whole‐mount histology (WMH) sections from postoperative radical prostatectomy specimens, an accurate estimate of the spatial extent of prostate cancer (CaP) on in vivo MR imaging (MRI) can be retrospectively established. This could allow for definition of quantitative image‐based disease signatures and lead to development of classifiers for disease detection on multiprotocol in vivo MRI. Automated registration of MR and WMH images of the prostate is complicated by dissimilar image intensities, acquisition artifacts, and nonlinear shape differences. Methods: The authors present a method for automated elastic registration of multiprotocol in vivo MRI and WMH sections of the prostate. The method, multiattribute combined mutual information (MACMI), leverages all available multiprotocol image data to drive image registration using a multivariate formulation of mutual information. Results: Elastic registration using the multivariate MI formulation is demonstrated for 150 corresponding sets of prostate images from 25 patient studies with T2‐weighted and dynamic‐contrast enhanced MRI and 85 image sets from 15 studies with an additional functional apparent diffusion coefficient MRI series. Qualitative results of MACMI evaluation via visual inspection suggest that an accurate delineation of CaP extent on MRI is obtained. Results of quantitative evaluation on 150 clinical and 20 synthetic image sets indicate improved registration accuracy using MACMI compared to conventional pairwise mutual information‐based approaches. Conclusions: The authors' approach to the registration of in vivo multiprotocol MRI and ex vivo WMH of the prostate using MACMI is unique, in that (1) information from all available image protocols is utilized to drive the registration with histology, (2) no additional, intermediate ex vivo radiology or gross histology images need be obtained in addition to the routinely acquired in vivo MRI series, and (3) no corresponding anatomical landmarks are required to be identified manually or automatically on the images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3560879

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Chappelow, J., Bloch, B. N., Rofsky, N., Genega, E., Lenkinski, R., DeWolf, W., & Madabhushi, A.
Venue
Medical Physics
Publisher
Wiley
Published
2011-03-21
Volume
38
Issue
4
Pages
2005-2018
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2085715108
Cited by
115
References
1
FWCI
18.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.