Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 285

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Quantitative analysis of the factors which affect the interpatient organ‐at‐risk dose sparing variation in IMRT plans

Yuan, Lulin, Ge, Yaorong, Lee, W. Robert, Yin, Fang Fang, Kirkpatrick, John P., Wu, Q. Jackie · 2012 · Medical Physics

Abstract

Purpose: The authors present an evidence‐based approach to quantify the effects of an array of patient anatomical features of the planning target volumes (PTVs) and organs‐at‐risk (OARs) and their spatial relationships on the interpatient OAR dose sparing variation in intensity modulated radiation therapy (IMRT) plans by learning from a database of high‐quality prior plans. Methods: The authors formulized the dependence of OAR dose volume histograms (DVHs) on patient anatomical factors into feature models which were learned from prior plans by a stepwise multiple regression method. IMRT plans for 64 prostate, 82 head‐and‐neck (HN) treatments were used to train the models. Two major groups of anatomical features were considered in this study: the volumetric information and the spatial information. The geometry of OARs relative to PTV is represented by the distance‐to‐target histogram, DTH. Important anatomical and dosimetric features were extracted from DTH and DVH by principal component analysis. The final models were tested by additional 24 prostate and 24 HN plans. Results: Significant patient anatomical factors contributing to OAR dose sparing in prostate and HN IMRT plans have been analyzed and identified. They are: the median distance between OAR and PTV, the portion of OAR volume within an OAR specific distance range, and the volumetric factors: the fraction of OAR volume which overlaps with PTV and the portion of OAR volume outside the primary treatment field. Overall, the determination coefficients R 2 for predicting the first principal component score (PCS1) of the OAR DVH by the above factors are above 0.68 for all the OARs and they are more than 0.53 for predicting the second principal component score (PCS2) of the OAR DVHs except brainstem and spinal cord. Thus, the above set of anatomical features combined has captured significant portions of the DVH variations for the OARs in prostate and HN plans. To test how well these features capture the interpatient organ dose sparing variations in general, the DVHs and specific dose‐volume indices calculated from the regression models were compared with the actual DVHs and dose‐volume indices from each patientˈs plan in the validation dataset. The dose‐volume indices compared were V99%, V85%, and V50% for bladder and rectum in prostate plans and parotids median dose in HN plans. The authors found that for the bladder and rectum models, 17 out of 24 plans (71%) were within 6% OAR volume error and 21 plans (85%) were within 10% error; For the parotids model, the median dose values for 30 parotids out of 48 (63%) were within 6% prescription dose error and the values in 40 parotids (83%) were within 10% error. Conclusions: Quantitative analysis of patient anatomical features and their correlation with OAR dose sparing has identified a number of important factors that explain significant amount of interpatient DVH variations in OARs. These factors can be incorporated into evidence‐based learning models as effective features to provide patient‐specific OAR dose sparing goals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.4757927

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 285

Metadata

Authors
Yuan, L., Ge, Y., Lee, W. R., Yin, F. F., Kirkpatrick, J. P., & Wu, Q. J.
Venue
Medical Physics
Publisher
Wiley
Published
2012-10-23
Volume
39
Issue
11
Pages
6868-6878
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2069905590
Cited by
285
References
9
FWCI
10.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.