The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Predicting dose‐volume histograms for organs‐at‐risk in IMRT planning
Abstract
Purpose: The objective of this work was to develop a quality control (QC) tool to reduce intensity modulated radiotherapy (IMRT) planning variability and improve treatment plan quality using mathematical models that predict achievable organ‐at‐risk (OAR) dose‐volume histograms (DVHs) based on individual patient anatomy. Methods: A mathematical framework to predict achievable OAR DVHs was derived based on the correlation of expected dose to the minimum distance from a voxel to the PTV surface. OAR voxels sharing a range of minimum distances were computed as subvolumes. A three‐parameter, skew‐normal probability distribution was used to fit subvolume dose distributions, and DVH prediction models were developed by fitting the evolution of the skew‐normal parameters as a function of distance with polynomials. Cohorts of 20 prostate and 24 head‐and‐neck IMRT plans with identical clinical objectives were used to train organ‐specific average models for rectum, bladder, and parotids. A sum of residuals analysis quantifying the integrated difference between the clinically approved DVH and predicted DVH evaluated similarity between DVHs. The ability of the average models to prospectively predict DVHs was evaluated on an independent validation cohort of 20 prostate plans. Statistical comparison of the sums of residuals between training and validation cohorts quantified the accuracy of the average model. Restricted sums of residuals (RSR) were used to identify potential outliers, where large values of RSR indicate a clinical DVH that exceeds the predicted DVH by a considerable amount. A refined model was obtained for each organ by excluding outliers with large RSR values from the training cohort. The refined model was applied to the original training cohort and restricted sums of residuals were utilized to estimate potential DVH improvements. All cases were replanned and evaluated by the physician that approved the original plan. The ability of the refined models to correctly identify outliers was assessed using the residual sum between the original and replanned DVHs to quantify dosimetric gains realized under replanning. Results: Statistical analysis of average sum of residuals for rectum (), bladder (), and parotid () training cohorts yielded mean values near zero and small with respect to the standard deviations, indicating that the average models are capturing the essential behavior of the training cohorts. The predictive abilities of the average rectum and bladder models were statistically indistinguishable between the training and validation sets, with and for the validation set. The refined models’ ability to detect outliers and predict achievable OAR DVHs was demonstrated by a strong correlation between predicted gains (RSR) and realized gains after replanning with sample correlation coefficients of r = 0.92 for the rectum, r = 0.88 for the bladder, and r = 0.84 for the parotid glands. Conclusions: The results demonstrate that our mathematical framework and modest training cohorts successfully predict achievable OAR DVHs based on individual patient anatomy. The models correctly identified suboptimal plans that demonstrated further OAR sparing after replanning. This modeling technique requires no manual intervention except for appropriate selection of a training set with identical evaluation criteria. Clinical implementation is in progress to evaluate impact on real‐time IMRT QC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Volumetric modulated arc therapy: IMRT in a single gantry arc
Otto, K. (2008) · Medical Physics · doi:10.1118/1.2818738 · Cited by 1,882
Bentzen, S. M., Constine, L. S., Deasy, J. O., Eisbruch, A., Jackson, A., Marks, L. B., Ten Haken, R. K., & Yorke, E. D. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.09.040 · Cited by 1,257
Reporting and analyzing dose distributions: A concept of equivalent uniform dose
Niemierko, A. (1997) · Medical Physics · doi:10.1118/1.598063 · Cited by 1,227
Bortfeld, T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r21 · Cited by 505
A planning quality evaluation tool for prostate adaptive IMRT based on machine learning
Zhu, X., Ge, Y., Li, T., Thongphiew, D., Yin, F., & Wu, Q. J. (2011) · Medical Physics · doi:10.1118/1.3539749 · Cited by 324
Modeling of normal tissue response to radiation: The critical volume model
Niemierko, A., & Goitein, M. (1993) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(93)90156-p · Cited by 307
Cited by
Artificial intelligence in radiation oncology
Huynh, E., Hosny, A., Guthier, C., Bitterman, D. S., Petit, S. F., Haas-Kogan, D. A., Kann, B., Aerts, H. J. W. L., & Mak, R. H. (2020) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-020-0417-8 · Cited by 419
Nguyen, D., Long, T., Jia, X., Lu, W., Gu, X., Iqbal, Z., & Jiang, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-37741-x · Cited by 352
Big Data and machine learning in radiation oncology: State of the art and future prospects
Bibault, J.-E., Giraud, P., & Burgun, A. (2016) · Cancer Letters · doi:10.1016/j.canlet.2016.05.033 · Cited by 346
Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.008 · Cited by 321
Nguyen, D., Jia, X., Sher, D., Lin, M.-H., Iqbal, Z., Liu, H., & Jiang, S. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab039b · Cited by 318
Metadata
- Authors
- Appenzoller, L. M., Michalski, J. M., Thorstad, W. L., Mutic, S., & Moore, K. L.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2012-11-27
- Volume
- 39
- Issue
- 12
- Pages
- 7446-7461
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1987419782
- Cited by
- 382
- References
- 6
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.