Noise considerations in dual energy CT scanning
Abstract
Dual energy CT scanning (tomochemistry) has been proposed as a method for determining various parameters relating to the elemental composition of the tissues. In this paper, our aim is to study the relative noise inherent in two proposed techniques for dual energy scanning: a “two crystal” technique and a “two kV” technique. In the two crystal technique, a split crystal detector is used to simultaneously obtain the high and low energy data during one scan at high kV. The two kV technique requires two scans taken with widely different kV settings. We first review three commonly used approaches for utilizing the scan data to compute the relevant parameters. A theoretical formalism is constructed which aids in understanding these methods. Then this formalism is used to study the influence of CT image noise on measurement precision in the case where the unknown parameters are densities. It is shown that, (1) the unavoidable overlap in the spectral data obtained by the two crystal technique results in a much lower signal‐to‐noise ratio than can be obtained by using the two kV technique, (2) the necessity for hard filtration of the high energy beam in the two kV technique has not heretofore been appreciated, and (3) the dose for a given x‐ray tube heat load is also lower with the two kV technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
Roessl, E., & Proksa, R. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/020 · Cited by 558
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Metadata
- Authors
- Kelcz, F., Joseph, P. M., & Hilal, S. K.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1979-09
- Volume
- 6
- Issue
- 5
- Pages
- 418-425
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2036525687
- Cited by
- 221
- References
- 0
- FWCI
- 0.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noise considerations in dual energy CT scanning. https://app.cochat.ai/papers/10.1118/1.594520
- The paper
- Kelcz, F., Joseph, P. M., & Hilal, S. K. (1979). Noise considerations in dual energy CT scanning. Medical Physics. https://doi.org/10.1118/1.594520
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.