CoChat

Tissue doses from radiotherapy of cancer of the uterine cervix

Stovall, Marilyn, Smith, Susan A., Rosenstein, Marvin · 1989 · Medical Physics
Cited by 87

The DOI matches its Crossref record.

Abstract

For use in an epidemiologic study of subsequent tumors, absorbed doses from brachytherapy and external beam radiotherapy were measured and calculated for various tissues of patients treated for cancer of the uterine cervix. External beams included orthovoltage x rays (1.9 and 3.0 mm Cu half‐value layer), cobalt‐60 gamma rays, 2 MV x rays, and 25 MV x rays. The brachytherapy sources were encapsulated radium. Measurements were made in an Alderson anthropomorphic phantom and a water phantom; calculations were made using a Monte Carlo technique or standard radiotherapy methods. Depending upon stage of disease and radiation energy, the absorbed doses (cGy) from typical treatment regimes to tissues of interest were: ovaries, 1400–5200; stomach, 130–320; kidneys, 120–310; pancreas, 100–260; lungs, 22–48; breasts, 19–52; thyroid, 6–17; salivary glands, 4–11; brain, 2–7, and total active bone marrow, 320–1100. The lower values of each range were for stage I of the disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.596331

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Stovall, M., Smith, S. A., & Rosenstein, M.
Venue
Medical Physics
Publisher
Wiley
Published
1989-09
Volume
16
Issue
5
Pages
726-733
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W1972999747
Cited by
87
References
0
FWCI
6.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.