Functional magnetic resonance imaging measurements of sound-level encoding in the absence of background scanner noise
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Effects of sound level on auditory cortical activation are seen in neuroimaging data. However, factors such as the cortical response to the intense ambient scanner noise and to the bandwidth of the acoustic stimuli will both confound precise quantification and interpretation of such sound-level effects. The present study used temporally “sparse” imaging to reduce effects of scanner noise. To achieve control for stimulus bandwidth, three schemes were compared for sound-level matching across bandwidth: component level, root-mean-square power and loudness. The calculation of the loudness match was based on the model reported by Moore and Glasberg [Acta Acust. 82, 335–345 (1996)]. Ten normally hearing volunteers were scanned using functional magnetic resonance imaging (fMRI) while listening to a 300-Hz tone presented at six different sound levels between 66 and 91 dB SPL and a harmonic-complex tone (F0=186 Hz) presented at 65 and 85 dB SPL. This range of sound levels encompassed all three bases of sound-level matching. Activation in the superior temporal gyrus, induced by each of the eight tone conditions relative to a quiet baseline condition, was quantified as to extent and magnitude. Sound level had a small, but significant, effect on the extent of activation for the pure tone, but not for the harmonic-complex tone, while it had a significant effect on the response magnitude for both types of stimulus. Response magnitude increased linearly as a function of sound level for the full range of levels for the pure tone. The harmonic-complex tone produced greater activation than the pure tone, irrespective of the matching scheme for sound level, indicating that bandwidth had a greater effect on the pattern of auditory activation than sound level. Nevertheless, when the data were collapsed across stimulus class, extent and magnitude were significantly correlated with the loudness scale (measured in phons), but not with the intensity scale (measured in SPL). We therefore recommend the loudness formula as the most appropriate basis of matching sound level to control for loudness effects when cortical responses to other stimulus attributes, such as stimulus class, are the principal concern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Motor Areas of the Medial Wall: A Review of Their Location and Functional Activation
Picard, N., & Strick, P. L. (1996) · Cerebral Cortex · doi:10.1093/cercor/6.3.342 · Cited by 1,712
GABA-A antagonist causes dramatic expansion of tuning in primary auditory cortex
Wang, J., Caspary, D., & Salvi, R. J. (2000) · NeuroReport · doi:10.1097/00001756-200004070-00045 · Cited by 145
Cited by
Gu, J. W., Halpin, C. F., Nam, E.-C., Levine, R. A., & Melcher, J. R. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00226.2010 · Cited by 310
Locating the initial stages of speech-sound processing in human temporal cortex
Uppenkamp, S., Johnsrude, I. S., Norris, D., Marslen-Wilson, W., & Patterson, R. D. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.004 · Cited by 189
“…indicates that, in humans, information is processed in a hierarchical manner in auditory cortex, and that this hierarchical organization extends into the multimodal regions beyond auditory cortex (Hall et al., 2001, 2003; Wessinger et al., 2001; Patterson et al., 2002; Scott and Johnsrude, 2003).”
BackgroundA review of hyperacusis and future directions: part II. Measurement, mechanisms, and treatment
Pienkowski, M., Tyler, R. S., Roncancio, E. R., Jun, H. J., Brozoski, T., Dauman, N., Coelho, C. B., Andersson, G., Keiner, A. J., Cacace, A. T., et al. (2014) · American Journal of Audiology · doi:10.1044/2014_aja-13-0037 · Cited by 138
“…a positive correlation between stimulus tone levels and the magnitude and extent of the blood oxygen level dependent responses in human and monkey auditory cortex (Bilecen, Seifritz, Scheffler, Henning, & Schulte, 2002; Hall et al., 2001; Hart, Hall, & Palmer, 2003; Tanji et al., 2010).”
BackgroundAudition of laughing and crying leads to right amygdala activation in a low-noise fMRI setting
Sander, K., Brechmann, A., & Scheich, H. (2003) · Brain Research Protocols · doi:10.1016/s1385-299x(03)00018-7 · Cited by 53
Metadata
- Authors
- Hall, D. A., Haggard, M. P., Summerfield, A. Q., Akeroyd, M. A., Palmer, A. R., & Bowtell, R. W.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2001-04-01
- Volume
- 109
- Issue
- 4
- Pages
- 1559-1570
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W1975848850
- Cited by
- 90
- References
- 3
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.