Threshold and channel interaction in cochlear implant users: Evaluation of the tripolar electrode configuration
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The efficacy of cochlear implants is limited by spatial and temporal interactions among channels. This study explores the spatially restricted tripolar electrode configuration and compares it to bipolar and monopolar stimulation. Measures of threshold and channel interaction were obtained from nine subjects implanted with the Clarion HiFocus-I electrode array. Stimuli were biphasic pulses delivered at 1020pulses∕s. Threshold increased from monopolar to bipolar to tripolar stimulation and was most variable across channels with the tripolar configuration. Channel interaction, quantified by the shift in threshold between single- and two-channel stimulation, occurred for all three configurations but was largest for the monopolar and simultaneous conditions. The threshold shifts with simultaneous tripolar stimulation were slightly smaller than with bipolar and were not as strongly affected by the timing of the two channel stimulation as was monopolar. The subjects’ performances on clinical speech tests were correlated with channel-to-channel variability in tripolar threshold, such that greater variability was related to poorer performance. The data suggest that tripolar channels with high thresholds may reveal cochlear regions of low neuron survival or poor electrode placement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transformed Up-Down Methods in Psychoacoustics
Levitt, H. (1971) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912375 · Cited by 5,477
Cited by
The Impact of Auditory Spectral Resolution on Listening Effort Revealed by Pupil Dilation
Winn, M. B., Edwards, J. R., & Litovsky, R. Y. (2015) · Ear & Hearing · doi:10.1097/aud.0000000000000145 · Cited by 278
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Spencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31
Khalili Moghadam, G., Wilke, R., Suaning, G. J., Lovell, N. H., & Dokos, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073130 · Cited by 18
Cicione, R., Fallon, J. B., Rathbone, G. D., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14754 · Cited by 17
Metadata
- Authors
- Bierer, J. A.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2007-03-01
- Volume
- 121
- Issue
- 3
- Pages
- 1642-1653
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2068262376
- Cited by
- 169
- References
- 1
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Threshold and channel interaction in cochlear implant users: Evaluation of the tripolar electrode configuration. https://app.cochat.ai/papers/10.1121/1.2436712
- The paper
- Bierer, J. A. (2007). Threshold and channel interaction in cochlear implant users: Evaluation of the tripolar electrode configuration. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.2436712
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.