Quasi-monopolar stimulation: a novel electrode design configuration for performance optimization of a retinal neuroprosthesis

Open access
Khalili Moghadam, Gita, Wilke, Robert, Suaning, Gregg J., Lovell, Nigel H., Dokos, Socrates·2013·PLoS ONE

Abstract

In retinal neuroprostheses, spatial interaction between electric fields from various electrodes - electric crosstalk - may occur in multielectrode arrays during simultaneous stimulation of the retina. Depending on the electrode design and placement, this crosstalk can either enhance or degrade the functional characteristics of a visual prosthesis. To optimize the device performance, a balance must be satisfied between the constructive interference of crosstalk on dynamic range and power consumption and its negative effect on artificial visual acuity. In the present computational modeling study, we have examined the trade-off in these positive and negative effects using a range of currently available electrode array configurations, compared to a recently proposed stimulation strategy - the quasi monopolar (QMP) configuration - in which the return current is shared between local bipolar guards and a distant monopolar electrode. We evaluate the performance of the QMP configuration with respect to the implantation site and electrode geometry parameters. Our simulation results demonstrate that the beneficial effects of QMP are only significant at electrode-to-cell distances greater than the electrode dimensions. Possessing a relatively lower activation threshold, QMP was found to be superior to the bipolar configuration in terms of providing a relatively higher visual acuity. However, the threshold for QMP was more sensitive to the topological location of the electrode in the array, which may need to be considered when programming the manner in which electrode are simultaneously activated. This drawback can be offset with a wider dynamic range and lower power consumption of QMP. Furthermore, the ratio of monopolar return current to total return can be used to adjust the functional performance of QMP for a given implantation site and electrode parameters. We conclude that the QMP configuration can be used to improve visual information-to-stimulation mapping in a visual prosthesis, while maintaining low power consumption.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0073130

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In monopolar stimulation, injected current spreads to the common distant ground, preventing confinement of electrical stimulation around the electrode and activating a large portion of neural tissue.

    “When the current is injected into the stimulating electrode, the electric field spreads to the common and distant ground, not allowing the confinement of the electrical stimulation around the electrode and resulting in the activation of a large portion of the neural tissue [13].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 41 references couldn’t be matched to a known paper.

Research works printed but not linked: 1

  1. [36]Lilly JC (1961) Injury and excitation by electric currents. Electrical stimulation of the brain. Austin, Texas: University of Texas Press. 60–64.

Cited by

Sorted by citations

Authors
Khalili Moghadam, G., Wilke, R., Suaning, G. J., Lovell, N. H., & Dokos, S.
Affiliations
UNSW Sydney (AU)
Corresponding author
Dokos, Socrates
Venue
PLoS ONE
Published
2013-08-26
Volume
8
Issue
8
Pages
e73130
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2131565716
Cited by
18
References
41
Citations by year
2026: 2 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 1
FWCI
0.65
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Australian Research Council
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
retinal prosthesis, microelectrode arrays, electrode design, monopolar electrodes, return current, visual acuity, activation threshold, dynamic range, power consumption
MeSH terms
Electrodes, Implanted, Equipment Design, Humans, Retina, Visual Acuity, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review