Vibrotactile frequency for encoding a speech parameter
The DOI matches its Crossref record.
Abstract
Frequency of vibration has not been widely used as a parameter for encoding speech-derived information on the skin. Where it has been used, the frequencies employed have not necessarily been compatible with the capabilities of the tactile channel, and no determination was made of the information transmitted by the frequency variable, as differentiated from other parameters used simultaneously, such as duration, amplitude, and location. However, several investigators have shown that difference limens for vibration frequency may be small enough to make stimulus frequency useful in encoding a speech-derived parameter such as the fundamental frequency of voiced speech. In the studies reported here, measurements have been made of the frequency discrimination ability of the volar forearm, using both sinusoidal and pulse waveforms. Stimulus configurations included the constant-frequency vibrations used by other laboratories as well as frequency-modulated (warbled) stimulus patterns. The frequency of a warbled stimulus was designed to have temporal variations analogous to those found in speech. The results suggest that it may be profitable to display the fundamental frequency of voiced speech on the skin as vibratory frequency, though it might be desirable to recode fundamental frequency into a frequency range more closely matched to the skin’s capability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tactile Displays: Guidance for Their Design and Application
Jones, L. A., & Sarter, N. B. (2008) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872008x250638 · Cited by 561
Application of Psychophysical Techniques to Haptic Research
Jones, L. A., & Tan, H. Z. (2013) · IEEE Transactions on Haptics · doi:10.1109/toh.2012.74 · Cited by 278
Natural scenes in tactile texture
Manfredi, L. R., Saal, H. P., Brown, K. J., Zielinski, M. C., Dammann, J. F., Polashock, V. S., & Bensmaia, S. J. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00680.2013 · Cited by 211
Haptic Codecs for the Tactile Internet
Steinbach, E., Strese, M., Eid, M., Liu, X., Bhardwaj, A., Liu, Q., Al-Ja'Afreh, M., Mahmoodi, T., Hassen, R., El Saddik, A., et al. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2867835 · Cited by 166
Novich, S. D., & Eagleman, D. M. (2015) · Experimental Brain Research · doi:10.1007/s00221-015-4346-1 · Cited by 148
Metadata
- Authors
- Rothenberg, M., Verrillo, R. T., Zahorian, S. A., Brachman, M. L., & Bolanowski, S. J.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1977-10-01
- Volume
- 62
- Issue
- 4
- Pages
- 1003-1012
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2080408958
- Cited by
- 132
- References
- 0
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibrotactile frequency for encoding a speech parameter. https://app.cochat.ai/papers/10.1121/1.381610
- The paper
- Rothenberg, M., Verrillo, R. T., Zahorian, S. A., Brachman, M. L., & Bolanowski, S. J. (1977). Vibrotactile frequency for encoding a speech parameter. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.381610
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.