The DOI matches its Crossref record.
Effect of a single interfering noise or speech source upon the binaural sentence intelligibility of aged persons
Abstract
The free-field speech-reception threshold (SRT) for sentences was investigated in quiet and under nine conditions involving noise or competing speech for a group of 20 elderly subjects (ten male, age 75–85; ten female, age 76–88) and a reference group of ten young normal-hearing subjects. The noise source had the same long-term average spectrum as the competing speech. The interfering signals were presented at a constant level of 55 dBA. All elderly subjects had moderate, nearly symmetrical pure-tone hearing losses with an average loss at 500, 1000, and 2000 Hz of between 9 and 40 dB re: ISO-389. The main results are (1) the SRT values in noise and competing speech are about equal, whereas the normal-hearing subjects showed a lower SRT (7 dB lower for the condition that both sound sources are in front) in competing speech than in noise; apparently, the elderly subjects do not benefit from the relatively silent periods in competing speech; (2) the gain obtained by moving the interfering noise source from the front to the lateral position is only 2.5 dB, in contrast to a gain of 9.6 dB for the young subjects; apparently, the elderly are unable to make full use of the spatial divergence between primary speaker and noise source.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Informational and energetic masking effects in the perception of two simultaneous talkers
Brungart, D. S. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1345696 · Cited by 1,139
Cognition counts: A working memory system for ease of language understanding (ELU)
Rönnberg, J., Rudner, M., Foo, C., & Lunner, T. (2008) · International Journal of Audiology · doi:10.1080/14992020802301167 · Cited by 489
Selective Attention in Normal and Impaired Hearing
Shinn-Cunningham, B. G., & Best, V. (2008) · Trends in Amplification · doi:10.1177/1084713808325306 · Cited by 437
Moore, B. C. J. (2008) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-008-0143-x · Cited by 421
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Effects of aging on auditory processing of speech
Pichora-Fuller, M. K., & Souza, P. E. (2003) · International Journal of Audiology · doi:10.3109/14992020309074638 · Cited by 363
Spatial release from informational masking in speech recognition
Freyman, R. L., Balakrishnan, U., & Helfer, K. S. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1354984 · Cited by 358
Cochlear implant speech recognition with speech maskers
Stickney, G. S., Zeng, F.-G., Litovsky, R., & Assmann, P. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1772399 · Cited by 340
Distraction by competing speech in young and older adult listeners.
Tun, P. A., O'Kane, G., & Wingfield, A. (2002) · Psychology and Aging · doi:10.1037//0882-7974.17.3.453 · Cited by 332
Freyman, R. L., Balakrishnan, U., & Helfer, K. S. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1689343 · Cited by 325
Speech‐in‐noise perception in high‐functioning individuals with autism or Asperger's syndrome
Alcántara, J. I., Weisblatt, E. J. L., Moore, B. C. J., & Bolton, P. F. (2004) · Journal of Child Psychology and Psychiatry · doi:10.1111/j.1469-7610.2004.t01-1-00303.x · Cited by 321
Peters, R. W., Moore, B. C. J., & Baer, T. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.421128 · Cited by 315
Moore, B. C. J. (1996) · Ear and Hearing · doi:10.1097/00003446-199604000-00007 · Cited by 273
Beutelmann, R., & Brand, T. (2006) · The Journal of the Acoustical Society of America · doi:10.1121/1.2202888 · Cited by 256
Adeel, A., Gogate, M., & Hussain, A. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.08.008 · Cited by 96
“In such cases, people with hearing impairment require the SNR to be improved by about 1 dB for every 10 dB of hearing loss, if they are to perceive speech as accurately as listeners with normal hearing [7].”
BackgroundLevy, E. S., Moya-Galé, G., Chang, Y. H. M., Freeman, K., Forrest, K., Brin, M. F., & Ramig, L. A. (2020) · eClinicalMedicine · doi:10.1016/j.eclinm.2020.100429 · Cited by 83
Aging Impairs the Ability to Ignore Irrelevant Information in Frequency Discrimination Tasks
Espinoza-Varas, B., & Jang, H. (2006) · Experimental Aging Research · doi:10.1080/03610730600554008 · Cited by 8
Metadata
- Authors
- Duquesnoy, A. J.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1983-09-01
- Volume
- 74
- Issue
- 3
- Pages
- 739-743
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2035505590
- Cited by
- 282
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.