Performance over time of adult patients using the Ineraid or Nucleus cochlear implant
The DOI matches its Crossref record.
Abstract
This study examined the average and individual performance over time of 49 adult cochlear implant subjects. Subjects were randomly assigned to receive either the Ineraid cochlear implant, with analog processing, or the Nucleus cochlear implant, with feature-extraction processing. All subjects had postlingual profound bilateral sensorineural hearing loss and received no significant benefit from hearing aids before implantation. Group data were examined in two ways. First, only subjects who had complete data over the test period were examined. Second, an analysis of all available data was carried out by mixed linear-model analysis. In this analysis, to account for missed follow-ups at the planned intervals, data consisting of the observations closest in time to the planned test times were modeled by natural splines with knots at the planned follow-up times. Contrasts between all pairs of planned follow-up times for each device were tested, as were contrasts between devices at each planned follow-up time. Results indicated little difference between the performance of the Ineraid and Nucleus subjects in their level of performance or their rate of learning. Postimplantation performance was typically superior to preimplantation performance within 9 months, and continued to improve up to 18–30 months depending on the speech perception measure. In some subjects, improvements in speech perception measures were observed up to four or five years postimplantation. There was also evidence that three subjects had a decrement in overall speech perception performance, although their postimplantation scores were always higher than their preimplantation scores. In at least one subject this was likely a result of age-related cognition decrements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Syka, J. (2002) · Physiological Reviews · doi:10.1152/physrev.00002.2002 · Cited by 369
Evidence that cochlear-implanted deaf patients are better multisensory integrators
Rouger, J., Lagleyre, S., Fraysse, B., Deneve, S., Deguine, O., & Barone, P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609419104 · Cited by 301
The emergence of Cognitive Hearing Science
ARLINGER, S., LUNNER, T., LYXELL, B., & KATHLEEN PICHORA‐FULLER, M. (2009) · Scandinavian Journal of Psychology · doi:10.1111/j.1467-9450.2009.00753.x · Cited by 231
Eisner, F., McGettigan, C., Faulkner, A., Rosen, S., & Scott, S. K. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.4040-09.2010 · Cited by 108
“Postlingually deafened, adult CI users commonly report that speech and the sensation of pitch sound very different from their previous memories, and it can take some time for users to adapt to the new input (Tyler et al., 1997; Reiss et al., 2007; Moore and Shannon, 2009).”
Background
Metadata
- Authors
- Tyler, R. S., Parkinson, A. J., Woodworth, G. G., Lowder, M. W., & Gantz, B. J.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1997-07-01
- Volume
- 102
- Issue
- 1
- Pages
- 508-522
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2077614538
- Cited by
- 154
- References
- 0
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.