The DOI matches its Crossref record.
Simulating the effect of cochlear-implant electrode insertion depth on speech understanding
Abstract
Normally hearing listeners were presented with vowels, consonants, and sentences for identification through an acoustic simulation of a five-channel cochlear implant with electrodes separated by 4 mm (as in the Ineraid implant). The aim of the experiment was to simulate the effect of depth of electrode insertion on identification accuracy. Insertion depth was simulated by outputing sine waves from each channel of the processor at a frequency determined by the cochlear place of electrodes inserted 22–25 mm into the cochlea. The results indicate that simulated insertion depth had a significant effect on performance. Performance at 22- and 23-mm simulated insertion depths was always poorer than normal, and performance at 25-mm simulated insertion depth was, most generally, the same as normal. It is inferred from these results that, if insertion depth could be unconfounded from other coexisting factors in implant patients, then insertion depth would be found to affect speech identification performance significantly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Davis, M. H., Johnsrude, I. S., Hervais-Adelman, A., Taylor, K., & McGettigan, C. (2005) · Journal of Experimental Psychology General · doi:10.1037/0096-3445.134.2.222 · Cited by 531
Frequency Map for the Human Cochlear Spiral Ganglion: Implications for Cochlear Implants
Stakhovskaya, O., Sridhar, D., Bonham, B. H., & Leake, P. A. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0076-9 · Cited by 414
Loizou, P. C. (1998) · IEEE Signal Processing Magazine · doi:10.1109/79.708543 · Cited by 326
Self-citationRosen, S., Faulkner, A., & Wilkinson, L. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.428215 · Cited by 253
Eisner, F., McGettigan, C., Faulkner, A., Rosen, S., & Scott, S. K. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.4040-09.2010 · Cited by 108
Metadata
- Authors
- Dorman, M. F., Loizou, P. C., & Rainey, D.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1997-11-01
- Volume
- 102
- Issue
- 5
- Pages
- 2993-2996
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W1999241803
- Cited by
- 183
- References
- 0
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simulating the effect of cochlear-implant electrode insertion depth on speech understanding. https://app.cochat.ai/papers/10.1121/1.420354
- The paper
- Dorman, M. F., Loizou, P. C., & Rainey, D. (1997). Simulating the effect of cochlear-implant electrode insertion depth on speech understanding. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.420354
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.