Reliability and Validity of Commercially Available Low-Cost Bioelectrical Impedance Analysis
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Research comparing portable body composition methods, such as bioelectrical impedance analysis (BIA), to air displacement plethysmography (ADP) is limited. We assessed reliability and validity of predicting fat-free mass (FFM) by the RJL, Omron, and Tanita BIA machines using ADP via BodPod as a criterion. FFM (kg) was assessed twice in college students (N = 77, 31 males and 46 females; age = 19.1 ± 1.2 years) using ADP, RJL, Omron, and Tanita BIAs. Reliability was assessed using analysis of variance to obtain an intraclass correlation statistic (R xx). Validity was assessed using Pearson correlation (r) coefficient. FFM averaged 75.6 ± 9.4 kg in men and 59.8 ± 7.6 kg in women. Reliability was high in both genders RJL (R xx = .974–.994), Omron (R xx = .933–.993), and Tanita (R xx = .921–.991). Validity within males was also high: RJL (r = .935), Omron (r = .942), and Tanita (r = .934), and only slightly lower in females: RJL (r = .924), Omron (r = .897), and Tanita (r = .898). The RJL, Omron, and Tanita BIA machines appear to be both reliable and valid for predicting FFM of male and female college students. Therefore, any of these three BIA devices is appropriate to use for body composition assessment in a healthy adult population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2014) · Medical Entomology and Zoology · Cited by 9,400
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896 · cited 1×
“With the ability to administer assessments outside of the laboratory setting more easily, the use of BIA in research and clinical settings has increased (Chumlea & Guo, 1994; Lukaski et al., 1985).”
MethodACSM’s Guidelines for Exercise Testing and Prescription 9th Ed. 2014
Ferguson, B. (2014) · Europe PMC (PubMed Central) · Cited by 919
Evaluation of a new air displacement plethysmograph for measuring human body composition
MCCRORY, M. A., GOMEZ, T. D., BERNAUER, E. M., & MOL??, P. A. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199512000-00016 · Cited by 512 · cited 3×
“…in many populations, and it has been used frequently as a criterion measure for field techniques in the past two decades, as other methods such as hydrodensitometry and dual-energy X-ray absorptiometry are not often available (Fields et al., 2000; McCrory et al., 1995; Tucker et al., 2014).”
BackgroundMethodResultInfluentialMeasurement for Evaluation in Physical Education and Exercise Science
Baumgartner, T. A., & Jackson, A. S. (1987) · Medical Entomology and Zoology · Cited by 464
Electrical impedance in assessing human body composition: the BIA method
Abu Khaled, M., McCutcheon, M., Reddy, S., Pearman, P., Hunter, G., & Weinsier, R. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.5.789 · Cited by 205 · cited 1×
“(Fornetti et al., 1999; Gibson et al., 2000; Kelly & Metcalfe, 2012; Khaled et al., 1988; Pribyl et al., 2011).”
Bioelectrical Impedance and Body Composition: Present Status and Future Directions
Chumlea, W. C., & Guo, S. S. (2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.1994.tb01404.x · Cited by 194 · cited 1×
“With the ability to administer assessments outside of the laboratory setting more easily, the use of BIA in research and clinical settings has increased (Chumlea & Guo, 1994; Lukaski et al., 1985).”
MethodValidation of the BOD POD with hydrostatic weighing: Influence of body clothingin
Fields, D., Hunter, G., & Goran, M. I. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801113 · Cited by 156 · cited 2×
“…in many populations, and it has been used frequently as a criterion measure for field techniques in the past two decades, as other methods such as hydrodensitometry and dual-energy X-ray absorptiometry are not often available (Fields et al., 2000; McCrory et al., 1995; Tucker et al., 2014).”
BackgroundMethodReliability and validity of body composition measures in female athletes
Fornetti, W. C., Pivarnik, J. M., Foley, J. M., & Fiechtner, J. J. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.3.1114 · Cited by 120 · cited 3×
“With respect to reliability, Fornetti et al. (1999) found the RJL machine to be highly reliable in a sample of female college athletes.”
MethodSelf-citationTest-Retest Reliability of the Bod Pod: The Effect of Multiple Assessments
Tucker, L. A., Lecheminant, J. D., & Bailey, B. W. (2014) · Perceptual and Motor Skills · doi:10.2466/03.pms.118k15w5 · Cited by 57
Cited by
Siedler, M. R., Rodriguez, C., Stratton, M. T., Harty, P. S., Keith, D. S., Green, J. J., Boykin, J. R., White, S. J., Williams, A. D., DeHaven, B., et al. (2023) · British Journal of Nutrition · doi:10.1017/s0007114522003749 · Cited by 50
“This model included body mass obtained via calibrated scale and body volume assessed via ADP (BodPod, Cosmed USA), bone mineral content obtained from DXA (Lunar Prodigy, General Electric, with enCORE software version 16.2) and total body water assessed via bioelectrical impedance spectroscopy (SFB7, Impedimed) using m…”
MethodInfluentialMartínez-Rodríguez, A., Martínez-Olcina, M., Hernández-García, M., Rubio-Arias, J. Á., Sánchez-Sánchez, J., Lara-Cobos, D., Vicente-Martínez, M., Carvalho, M. J., & Sánchez-Sáez, J. A. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18062837 · Cited by 33
(2022) · PubMed Central · Cited by 9
Metadata
- Authors
- Vasold, K. L., Parks, A. C., Phelan, D. M. L., Pontifex, M. B., & Pivarnik, J. M.
- Venue
- International Journal of Sport Nutrition and Exercise Metabolism
- Publisher
- Human Kinetics
- Published
- 2019-07-01
- Volume
- 29
- Issue
- 4
- Pages
- 406-410
- ISSN
- 1526-484X (ISSN-L)
- 1543-2742
- OpenAlex
- W2903479880
- Cited by
- 174
- References
- 13
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability and Validity of Commercially Available Low-Cost Bioelectrical Impedance Analysis. https://app.cochat.ai/papers/10.1123/ijsnem.2018-0283
- The paper
- Vasold, K. L., Parks, A. C., Phelan, D. M. L., Pontifex, M. B., & Pivarnik, J. M. (2019). Reliability and Validity of Commercially Available Low-Cost Bioelectrical Impedance Analysis. International Journal of Sport Nutrition and Exercise Metabolism. https://doi.org/10.1123/ijsnem.2018-0283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.