CoChat

The Validity of Microsensors to Automatically Detect Bowling Events and Counts in Cricket Fast Bowlers

McNamara, Dean J., Gabbett, Tim J., Chapman, Paul, Naughton, Geraldine, Farhart, Patrick · 2015 · International Journal of Sports Physiology and Performance

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Purpose: Bowling workload is linked to injury risk in cricket fast bowlers. This study investigated the validity of microtechnology in the automated detection of bowling counts and events, including run-up distance and velocity, in cricket fast bowlers. Method: Twelve highly skilled fast bowlers (mean ± SD age 23.5 ± 3.7 y) performed a series of bowling, throwing, and fielding activities in an outdoor environment during training and competition while wearing a microtechnology unit (MinimaxX). Sensitivity and specificity of a bowling-detection algorithm were determined by comparing the outputs from the device with manually recorded bowling counts. Run-up distance and run-up velocity were measured and compared with microtechnology outputs. Results: No significant differences were observed between direct measures of bowling and nonbowling events and true positive and true negative events recorded by the MinimaxX unit (P = .34, r = .99). The bowling-detection algorithm was shown to be sensitive in both training (99.0%) and competition (99.5%). Specificity was 98.1% during training and 74.0% during competition. Run-up distance was accurately recorded by the unit, with a percentage bias of 0.8% (r = .90). The final 10-m (–8.9%, r = .88) and 5-m (–7.3%, r = .90) run-up velocities were less accurate. Conclusions: The bowling-detection algorithm from the MinimaxX device is sensitive to detect bowling counts in both cricket training and competition. Although specificity is high during training, the number of false positive events increased during competition. Additional bowling workload measures require further development.

Overview

Integrity signals

Registry

Crossref · 10.1123/ijspp.2014-0062

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Cited by

See all 69

Metadata

Authors
McNamara, D. J., Gabbett, T. J., Chapman, P., Naughton, G., & Farhart, P.
Affiliations
Australian Catholic University (AU)
Venue
International Journal of Sports Physiology and Performance
Published
2015-01
Volume
10
Issue
1
Pages
71-75
ISSN
  • 1555-0265 (ISSN-L)
  • 1555-0273
OpenAlex
W2165782109
Cited by
69
References
15
Citations by year
2026: 1 · 2025: 4 · 2024: 1 · 2023: 3 · 2022: 5 · 2021: 12 · 2020: 10 · 2019: 5 · 2018: 11 · 2017: 7 · 2016: 6 · 2015: 4
FWCI
2.94
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Sports Physiology and Performance (publishedVersion)
  • PubMed (publishedVersion)
  • Research Bank (Australian Catholic University) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports injuries and prevention
Keywords
sensor validity, sensitivity and specificity
MeSH terms
Adult, Algorithms, Competitive Behavior, Humans, Physical Education and Training, Sports, Reproducibility of Results, Workload, Geographic Information Systems, Microtechnology, Young Adult, Magnetometry, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Validity of Microsensors to Automatically Detect Bowling Events and Counts in Cricket Fast Bowlers. https://app.cochat.ai/papers/10.1123/ijspp.2014-0062
The paper
McNamara, D. J., Gabbett, T. J., Chapman, P., Naughton, G., & Farhart, P. (2015). The Validity of Microsensors to Automatically Detect Bowling Events and Counts in Cricket Fast Bowlers. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2014-0062

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.