Validity, Sensitivity, Reproducibility, and Robustness of the PowerTap, Stages, and Garmin Vector Power Meters in Comparison With the SRM Device
Open accessThe DOI matches its Crossref record; 35 of the 37 references it cites were found in a registry or an index.
Abstract
A large number of power meters have been produced on the market for nearly 20 y according to user requirements. Purpose: To determine the validity, sensitivity, reproducibility, and robustness of the PowerTap (PWT), Stages (STG), and Garmin Vector (VCT) power meters in comparison with the SRM device. Methods: A national-level male competitive cyclist completed 3 laboratory cycling tests: a submaximal incremental test, a submaximal 30-min continuous test, and a sprint test. Two additional tests were performed, the first on vibration exposures in the laboratory and the second in the field. Results: The VCT provided a significantly lower 5-s power output (PO) during the sprint test with a low gear ratio than the SRM did (–36.9%). The STG PO was significantly lower than the SRM PO in the heavy-exercise-intensity zone (zone 2, –5.1%) and the low part of the severe-intensity zone (zone 3, –4.9%). The VCT PO was significantly lower than the SRM PO only in zone 2 (–4.5%). The STG PO was significantly lower in standing position than in the seated position (–4.4%). The reproducibility of the PWT, STG, and VCT was similar to that of the SRM system. The STG and VCT PO were significantly decreased from a vibration frequency of 48 Hz and 52 Hz, respectively. Conclusions: The PWT, STG, and VCT systems appear to be reproducible, but the validity, sensitivity, and robustness of the STG and VCT systems should be treated with some caution according to the conditions of measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In cycling and middle‐distance running, training load can be accurately monitored using power meters or global‐positioning systems (GPS) (Bouillod et al., 2017; Gloersen et al., 2018).”
From Agreement between muscle saturation breakpoints and lactate thresholds: Muscles comparison and sex difference in world‐class Nordic skiers (2026) · cites this paper as Bouillod et al., 2017
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Medicine and Science in Sports and Exercise-1980
Tipton, C. M. (1980) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198021000-00001 · Cited by 1,631
International Journal of Sports Medicine
(2026) · International Journal of Sports Medicine · doi:10.1055/s-00000028 · Cited by 966
Bartlett, J. W., & Frost, C. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5256 · Cited by 936
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Nevill, A. M., & Atkinson, G. (1997) · British Journal of Sports Medicine · doi:10.1136/bjsm.31.4.314 · Cited by 317
On the bilateral asymmetry during running and cycling – A review considering leg preference
Carpes, F. P., Mota, C. B., & Faria, I. E. (2010) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2010.06.005 · Cited by 257 · cited 1×
“16 , measured by combining intensity and duration with the SRM torque analysis system in our laboratory (personal data), volunteered as the subject for this study.”
MethodAerodynamic drag in field cycling with special reference to the Obree's position
Grappe, F., Candau, R. B., Belli, A., & Rouillon, J. D. (1997) · Ergonomics · doi:10.1080/001401397187388 · Cited by 184
Self-citationAccuracy of SRM and Power Tap Power Monitoring Systems for Bicycling
GARDNER, A. S., STEPHENS, S., MARTIN, D. T., LAWTON, E., LEE, H., & JENKINS, D. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000132380.21785.03 · Cited by 183
Research works printed but not linked: 2
- Bouillod A, Pinot J, Valade A, Cassirame J, Soto-Romero G, Grappe F. Gross efficiency is improved in standing position with an increase of the power output. Journal of Science and Cycling. 2014;3(2):6.
- "Validity, Sensitivity, Reproducibility and Robustness of the Powertap, Stages and Garmin Vector Power Meters in Comparison With the SRM Device" by Bouillod A et al. International Journal of Sports Physiology and Performance © 2016 Human Kinetics, Inc.
Cited by
The Record Power Profile of Male Professional Cyclists: Fatigue Matters
Mateo‐March, M., Valenzuela, P. L., Muriel, X., Gandía-Soriano, A., Zabala, M., Lucia, A., Pallarés, J. G., & Barranco‐Gil, D. (2022) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2021-0403 · Cited by 70
Sanders, D., Taylor, R. J., Myers, T., & Akubat, I. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001910 · Cited by 52
Validity and Reliability of the Cycleops Hammer Cycle Ergometer
Lillo-Beviá, J. R., & Pallarés, J. G. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2017-0403 · Cited by 42
Yang, W., Park, S., Kim, T., Jeon, H.-J., Heine, O., & Gehlert, S. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1147321 · Cited by 40
“5–1% according to themanufacturer and previous studies (Bouillod et al., 2017; Nimmerichter et al., 2017; Montalvo-Pérez et al., 2021).”
Using Field Based Data to Model Sprint Track Cycling Performance
Ferguson, H. A., Harnish, C., & Chase, J. G. (2021) · Sports Medicine - Open · doi:10.1186/s40798-021-00310-0 · Cited by 37
Bouillod, A., Soto-Romero, G., Grappe, F., Bertucci, W., Brunet, E., & Cassirame, J. (2022) · Sensors · doi:10.3390/s22010386 · Cited by 36
“Reproducibility refers to the variation in measurements made on a power meter under changing conditions [51,54].”
BackgroundMethodInfluentialSelf-citationValidity and Reliability of the PowerTap P1 Pedals Power Meter.
Pallarés, J. G., & Lillo-Beviá, J. R. (2018) · Europe PMC (PubMed Central) · Cited by 34
Cerezuela‐Espejo, V., Hernández‐Belmonte, A., Courel‐Ibáñez, J., Conesa‐Ros, E., Martínez-Cava, A., & Pallarés, J. G. (2020) · Physiology & Behavior · doi:10.1016/j.physbeh.2020.112972 · Cited by 34
A survey of mathematical models of human performance using power and energy
Sreedhara, V. S. M., Mocko, G. M., & Hutchison, R. E. (2019) · Sports Medicine - Open · doi:10.1186/s40798-019-0230-z · Cited by 32
“Similar to studies in [101, 102], commercially available sensors could be validated against laboratory equipment and used in the field for developing higher fidelity models.”
ResultKoontz, A. M., Garfunkel, C. E., Crytzer, T. M., Anthony, S. J., & Nindl, B. C. (2020) · Spinal Cord · doi:10.1038/s41393-020-00548-7 · Cited by 30
Validity of the Favero Assioma Duo Power Pedal System for Measuring Power Output and Cadence
Montalvo‐Pérez, A., Alejo, L. B., Valenzuela, P. L., Castellanos, M., Gil-Cabrera, J., Talavera, E., Lucía, A., & Barranco‐Gil, D. (2021) · Sensors · doi:10.3390/s21072277 · Cited by 30
“The CV of the PO meters for block one (submaximal incremental test) shows similarities to previous studies comparing pedal power meters and the SRM device [1,22] and are consistent with the CV of the SRM obtained by Hutchinson et al.”
BackgroundMethodResultInfluentialAre the Assioma Favero Power Meter Pedals a Reliable Tool for Monitoring Cycling Power Output?
Rodríguez-Rielves, V., Lillo-Beviá, J. R., Buendía‐Romero, Á., Martínez-Cava, A., Hernández‐Belmonte, A., Courel‐Ibáñez, J., & Pallarés, J. G. (2021) · Sensors · doi:10.3390/s21082789 · Cited by 25
“Given that the current experiment was conducted under laboratory settings, future research should address the reliability of the Assioma Favero Pedals in field conditions [15].”
BackgroundMethodInfluentialRønnestad, B. R., Moen, M., Gunnerød, S., & Øfsteng, S. J. (2018) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13277 · Cited by 21
Development and field validation of an omni-domain power-duration model
Puchowicz, M. J., Baker, J., & Clarke, D. C. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1735609 · Cited by 19
Cartón-Llorente, A., Roche-Seruendo, L. E., Jaén‐Carrillo, D., Marcén-Cinca, N., & García‐Pinillos, F. (2021) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/1754337120984644 · Cited by 15
Influence of standing position on mechanical and energy costs in uphill cycling
Bouillod, A., Pinot, J., Valade, A., Cassirame, J., Soto-Romero, G., & Grappe, F. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.02.034 · Cited by 14
Self-citationSoriano, A. G., Carpes, F. P., Fernandez, A. R., & Priego‐Quesada, J. I. (2020) · European Journal of Sport Science · doi:10.1080/17461391.2020.1785016 · Cited by 13
Rodríguez-Rielves, V., Martínez-Cava, A., Buendía‐Romero, Á., Lillo-Beviá, J. R., Courel‐Ibáñez, J., Hernández‐Belmonte, A., & Pallarés, J. G. (2021) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2021-0137 · Cited by 13
The impact of the COVID-19 pandemic on the diet, training habits and fitness of Masters cyclists
Shaw, K. A., Bertrand, L., Deprez, D., Ko, J., Zello, G. A., & Chilibeck, P. D. (2022) · Nutrition and Health · doi:10.1177/02601060211002350 · Cited by 12
Bennett, S. E., Tiollier, E., Brocherie, F., Owens, D. J., Morton, J. P., & Louis, J. B. (2021) · PLoS ONE · doi:10.1371/journal.pone.0260959 · Cited by 12
Morais, J. E., Bragada, J. A. A., Magalhães, P. M., & Marinho, D. A. (2024) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk9030138 · Cited by 11
“Similar findings were reported by other authors who used the same first version of the GV pedals [1].”
BackgroundMethodResultInfluentialHebisz, R. G., & Hebisz, P. (2024) · PLoS ONE · doi:10.1371/journal.pone.0311833 · Cited by 11
The reliability and accuracy of the Garmin Vector 3 power pedals
Dickinson, T., & Wright, J. (2020) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/1754337120961600 · Cited by 10
Iglesias-Pino, J., Herrero-Molleda, A., García, M. S., & García-López, J. (2023) · Sensors · doi:10.3390/s23187745 · Cited by 10
“0 W at a pedaling intensity between 150 and 350 W) [4] and Power2Max (1–2% at a pedaling intensity between 200 and 315 W) [1].”
BackgroundMethodResultInfluentialValidity of PowerTap P1 Pedals during Laboratory-Based Cycling Time Trial Performance
Whittle, C., Smith, N. A., & Jobson, S. (2018) · Sports · doi:10.3390/sports6030092 · Cited by 10
“During incremental tests, non-significant differences in mean power output between devices were found [18], with LoA analysis highlighting a bias of 13.”
BackgroundMethodResultInfluentialValidity of the Favero Assioma Duo Power Pedal System in Maximal-Effort Cycling Tests
Yeh, M., Chen, W.-H., Lu, S.-T., Chen, C., Liu, Y.-C., & Liu, C. (2022) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2021-0384 · Cited by 9
Competitive Racing in Virtual Cycling—Is It Possible, Realistic, and Fair?
Bjärehed, J., & Bjärehed, M. (2022) · Journal of Electronic Gaming and Esports · doi:10.1123/jege.2022-0006 · Cited by 9
Validity of the Velocomp PowerPod Compared With the Verve Cycling InfoCrank Power Meter
Merkes, P. F. J., Menaspà, P., & Abbiss, C. R. (2019) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2018-0790 · Cited by 9
“Introduction 46 Cycling power meters typically rely on a measurement of crank arm, chain, pedal, or 47 rear hub torque and angular velocity to calculate power output.(1) There are several models of 48 power meters available on the market, with many validated against the SRM power meter(1-6) or 49 a mathematical model…”
MethodBini, R. R., & Hume, P. A. (2020) · Human Movement · doi:10.5114/hm.2020.94197 · Cited by 7
Validity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device
Hutchison, R. E., Klapthor, G. A. E., Edwards, K. S., Bruneau, K., Mocko, G. M., & Vahidi, A. (2017) · Journal of Sports Science · doi:10.17265/2332-7839/2017.05.001 · Cited by 7
Physiological Responder Profiles and Fatigue Dynamics in Prolonged Cycling
Odriozola-Martínez, A., Tîrnȃucȃ, C., Corbi, F., González, A., & Álvarez‐Herms, J. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10040472 · Cited by 6
Shute, R. J., Zak, R., & Slivka, D. R. (2019) · Journal Of Science & Cycling · doi:10.28985/jsc.v8i1.504 · Cited by 6
“Additionally, the Stages may underestimate both average and peak power when compared to the SRM (Bouillod et al., 2017; Hurst et al., 2015).”
InfluentialThe Validity and Reliability of a Tire Pressure-Based Power Meter for Indoor Cycling
Fiolo, N. J., Lu, H.-Y., Chen, C.-H., Fuchs, P. X., Chen, W.-H., & Shiang, T.-Y. (2021) · Sensors · doi:10.3390/s21186117 · Cited by 6
“Hutchinson and colleagues [15] reported greater disagreement between the Garmin Vector pedal-based power meter and the SRM than those reported in other investigations [7,16,17].”
BackgroundResultInfluentialKnechtle, B., Forte, P. M., Weiss, K., Čuk, I., Nikolaidis, P. Τ., Sousa, C. V., Andrade, M. S., & Thuany, M. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.990382 · Cited by 6
“Therefore, the HR analysis between competitions provides a better understanding of the load and intensity of the exercise and racing strategies (19, 20, 23).”
BackgroundPower output reliability between Garmin® Vector meter and Lode Excalibur Sport® cycle ergometer
Lanferdini, F. J., Sperb, C. H., da Rocha, E. S., Baptista, R. R., & Vaz, M. A. (2020) · Research on Biomedical Engineering · doi:10.1007/s42600-020-00073-9 · Cited by 5
Iglesias-Pino, J., Herrero-Molleda, A., Fernández-Fernández, J., & García-López, J. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192416446 · Cited by 5
“This latter could condition the analysis and interpretation of both exercise intensity zones and power output profile of the cyclists [2,5,7], and their critical power [8,9].”
BackgroundResultInfluentialWorn, R. L., & Dwyer, D. (2019) · Journal Of Science & Cycling · doi:10.28985/jsc.v8i1.396 · Cited by 5
“…power meters and comparisons between them (Abbiss et al. 2009; Bertucci et al. 2005; Duc et al. 2007; Staplefeldt et al. 2007; Wooles et al. 2005; Bouillod et al. 2017), there are very few reports of the accuracy of commercially available research grade bicycle crank systems that measure crank…”
BackgroundValenzuela, P. L., Montalvo‐Pérez, A., Alejo, L. B., Castellanos, M., Gil-Cabrera, J., Talavera, E., Lucía, A., & Barranco‐Gil, D. (2021) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2021-0278 · Cited by 4
An investigation of asymmetries in cycling: methods and performance implications
Kelly, M. (2023) · Open Access at Essex (University of Essex) · Cited by 4
Murray, K., Schoenmakers, P., Taylor, M., & Sandercock, G. (2024) · Journal Of Science & Cycling · doi:10.28985/1324.jsc.07 · Cited by 3
“It is worth noting that commercial pedal power meters typically sample at low frequencies (1 Hz), which has been shown to reduce the validity of net power measured during sprint cycling at high cadences (Bouillord et al., 2017; Novak & Dascombe, 2016).”
Bouillod, A., Retali, M., Soto-Romero, G., Brunet, E., Frémeaux, M., Cassirame, J., Maillot, J., & Grappe, F. (2020) · Journal Of Science & Cycling · doi:10.28985/0620.jsc.01 · Cited by 2
“PO and V were measured throughout the two testing sessions with a Powertap G3 hub located at the rear wheel (Bouillod et al., 2017) using a frequency of 1 Hz and were recorded in a Garmin power control (Garmin 810, Olathe, USA).”
MethodSelf-citationSachet, I. (2022) · theses.fr (ABES) · doi:10.70675/9ad1614fzd9e4z4f7cza8c0zc65031bf722d · Cited by 2
Forot, J., Schorderet, F., Burdet, C., Brocherie, F., & Millet, G. P. (2026) · Experimental Physiology · doi:10.1113/ep093311 · Cited by 1
“However, in cross-country skiing and biathlon, terrain variability rather complicates load monitoring, as power meters are limited to upper-limb measurements (e.g., pole sensors), and GPS-based resistance estimations are imprecise due to variations in snow conditions (Gloersen & Gilgien, 2021; Zhao et al., 2023).”
WheelPower: Wheelchair Sports and Data Science Push It to the Limit
Vegter, R. J. K., Janssen, R. J. F., van Dijk, M. P., Hoozemans, M. J. M., Veeger, H. E. J., Houdijk, H., van der Woude, L., Berger, M., van der Slikke, R. M. A., & de Groot, S. (2024) · DROPS (Schloss Dagstuhl – Leibniz Center for Informatics) · doi:10.4230/oasics.commit2data.6 · Cited by 1
Role‐Specific Performance Profiles of Professional Cyclists in a Grand Tour
Sánchez‐Jiménez, J. L., JAVALOYES, A., Barranco‐Gil, D., Peña‐González, I., Moya‐Ramón, M., & Mateo‐March, M. (2026) · European Journal of Sport Science · doi:10.1002/ejsc.70170 · Cited by 1
Positions sur le vélo et performance en cyclisme
Bouillod, A. (2017) · theses.fr (ABES) · doi:10.70675/10e17edaz62efz4652z9760zb39a144ba344 · Cited by 1
Self-citationRecumbent handbike set-up for sports performance
Stone, B. (2019) · Figshare · doi:10.26174/thesis.lboro.10565795 · Cited by 1
Paratriathletes' physiological and thermoregulatory response to training load and competition
Stephenson, B. T. (2019) · Loughborough University Institutional Repository (Loughborough University) · doi:10.13140/rg.2.2.11842.73929
Modeling Energy Expenditure and Recovery in Cycling
Sreedhara, V. S. M. (2020) · TigerPrints (Clemson University)
Granier, C. (2018) · theses.fr (ABES) · doi:10.70675/953e5e40ze48ez4677zb669z7d4621878350
The effect of saddle height on pedalling mechanical efficiency during cycling
Peleg, S., Ravina, O., & Steinberg, N. (2025) · International Journal of Performance Analysis in Sport · doi:10.1080/24748668.2025.2493459
“This power meter is considered a gold standard for mechanical performance among cyclists and was proved to be valid and reliable (Bouillod et al., 2017; Jones & Passfield, 1998; Martin et al., 1998).”
Validity of the Quarq Cycling Power Meter
Oteo-Gorostidi, J., Cámara, J., Ojanguren, D., Iriberri, J., Ventura, I. V., & Montalvo‐Pérez, A. (2025) · Sensors · doi:10.3390/s25092717
“Similar to previous validation studies of power meters installed in pedals and spiders [9,10,22], this study also observed increasing typical errors proportional to average power, indicating greater precision at lower power levels compared to maximum power efforts (e.g., all-out and P max ).”
InfluentialLi, G., Li, X., Yang, D., Li, M., Gao, Y., & Tong, Y. (2025) · Research Square · doi:10.21203/rs.3.rs-6600352/v1
Building a power meter for cycling
Toma, R., & Breazu, M. (2025) · International Journal of Advanced Statistics and IT&C for Economics and Life Sciences · doi:10.2478/ijasitels-2025-0017
“The main categories include systems mounted on the bottom bracket, in the pedals, in the rear wheel hub, and other solutions such as in the gear or optical sensors, each tailored to different needs and budgets [5].”
InfluentialBustingorri Eguaras, P. (2023) · Buleria (Universidad de León)
Hrbotický, L. (2022) · Brno University of Technology Digital Library (Brno University of Technology)
Pascual-Redondo, H. (2023) · Buleria (Universidad de León)
Can electric mountain bikes keep you just as active and healthy as traditional mountain bikes?
Castán, J. C. R., Velasco, J. M. I., Jiménez, M. R., & Campo, S. S. (2026) · Retos · doi:10.47197/retos.v76.117884
Doy, H. J. (2026) · Kent Academic Repository (University of Kent) · doi:10.22024/unikent/01.02.113247
LaserFit: A Low-Cost Laser-Based Optical Power Meter for Cycling
Lubarsky, G. (2026) · Metrology · doi:10.3390/metrology6030055
“Applying that framework, recent work has quantified the behavior of crank-, pedal-and hub-based systems against the SRM reference [24–27], and has also examined non-strain-gauge approaches such as tire-pressure sensing [28].”
Physical demands and power profile of different stage types within a cycling grand tour
Sanders, D., & Heijboer, M. (2019) · European Journal of Sport Science · doi:10.1080/17461391.2018.1554706 · Cited by 68
Metadata
- Authors
- Bouillod, A., Pinot, J., Soto-Romero, G., Bertucci, W., & Grappe, F.
- Affiliations
- Laboratoire d'Analyse et d'Architecture des Systèmes (FR)
- Laboratoire Culture, Sport, Santé, Société (FR)
- Université de Reims Champagne-Ardenne (FR)
- Corresponding author
- Bouillod, Anthony
- Venue
- International Journal of Sports Physiology and Performance
- Publisher
- Human Kinetics
- Published
- 2017-09
- Volume
- 12
- Issue
- 8
- Pages
- 1023-1030
- ISSN
- 1555-0265 (ISSN-L)
- 1555-0273
- OpenAlex
- W2567421351
- Semantic Scholar
- ed54e6a7ea03b55f6bf12ac2a2b7297cbe73b144
- Cited by
- 49
- References
- 37
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 2 · 2023: 3 · 2022: 6 · 2021: 9 · 2020: 8 · 2019: 5 · 2018: 5 · 2017: 3
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- other-oa
- Locations
- International Journal of Sports Physiology and Performance (publishedVersion, other-oa)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- power meters, stage, SRM, power output measurement, measurement validity, measurement sensitivity, reproducibility, robustness, vibration interference, cycling, sprint test, incremental test, gear ratio
- MeSH terms
- Bicycling, Equipment Design, Exercise Test, Humans, Male, Sensitivity and Specificity, Reproducibility of Results, Ergometry, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.