Validity, Sensitivity, Reproducibility, and Robustness of the PowerTap, Stages, and Garmin Vector Power Meters in Comparison With the SRM Device
Open accessThe DOI matches its Crossref record; 35 of the 37 references it cites were found in a registry or an index.
Abstract
A large number of power meters have been produced on the market for nearly 20 y according to user requirements. Purpose: To determine the validity, sensitivity, reproducibility, and robustness of the PowerTap (PWT), Stages (STG), and Garmin Vector (VCT) power meters in comparison with the SRM device. Methods: A national-level male competitive cyclist completed 3 laboratory cycling tests: a submaximal incremental test, a submaximal 30-min continuous test, and a sprint test. Two additional tests were performed, the first on vibration exposures in the laboratory and the second in the field. Results: The VCT provided a significantly lower 5-s power output (PO) during the sprint test with a low gear ratio than the SRM did (–36.9%). The STG PO was significantly lower than the SRM PO in the heavy-exercise-intensity zone (zone 2, –5.1%) and the low part of the severe-intensity zone (zone 3, –4.9%). The VCT PO was significantly lower than the SRM PO only in zone 2 (–4.5%). The STG PO was significantly lower in standing position than in the seated position (–4.4%). The reproducibility of the PWT, STG, and VCT was similar to that of the SRM system. The STG and VCT PO were significantly decreased from a vibration frequency of 48 Hz and 52 Hz, respectively. Conclusions: The PWT, STG, and VCT systems appear to be reproducible, but the validity, sensitivity, and robustness of the STG and VCT systems should be treated with some caution according to the conditions of measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In cycling and middle‐distance running, training load can be accurately monitored using power meters or global‐positioning systems (GPS) (Bouillod et al., 2017; Gloersen et al., 2018).”
From Agreement between muscle saturation breakpoints and lactate thresholds: Muscles comparison and sex difference in world‐class Nordic skiers (2026) · cites this paper as Bouillod et al., 2017
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Medicine and Science in Sports and Exercise-1980
Tipton, C. M. (1980) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198021000-00001 · Cited by 1,631
International Journal of Sports Medicine
(2026) · International Journal of Sports Medicine · doi:10.1055/s-00000028 · Cited by 966
Bartlett, J. W., & Frost, C. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5256 · Cited by 936
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Nevill, A. M., & Atkinson, G. (1997) · British Journal of Sports Medicine · doi:10.1136/bjsm.31.4.314 · Cited by 317
On the bilateral asymmetry during running and cycling – A review considering leg preference
Carpes, F. P., Mota, C. B., & Faria, I. E. (2010) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2010.06.005 · Cited by 257 · cited 1×
“16 , measured by combining intensity and duration with the SRM torque analysis system in our laboratory (personal data), volunteered as the subject for this study.”
MethodAerodynamic drag in field cycling with special reference to the Obree's position
Grappe, F., Candau, R. B., Belli, A., & Rouillon, J. D. (1997) · Ergonomics · doi:10.1080/001401397187388 · Cited by 184
Self-citationAccuracy of SRM and Power Tap Power Monitoring Systems for Bicycling
GARDNER, A. S., STEPHENS, S., MARTIN, D. T., LAWTON, E., LEE, H., & JENKINS, D. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000132380.21785.03 · Cited by 183
Research works printed but not linked: 2
- Bouillod A, Pinot J, Valade A, Cassirame J, Soto-Romero G, Grappe F. Gross efficiency is improved in standing position with an increase of the power output. Journal of Science and Cycling. 2014;3(2):6.
- "Validity, Sensitivity, Reproducibility and Robustness of the Powertap, Stages and Garmin Vector Power Meters in Comparison With the SRM Device" by Bouillod A et al. International Journal of Sports Physiology and Performance © 2016 Human Kinetics, Inc.
Cited by
The Record Power Profile of Male Professional Cyclists: Fatigue Matters
Mateo‐March, M., Valenzuela, P. L., Muriel, X., Gandía-Soriano, A., Zabala, M., Lucia, A., Pallarés, J. G., & Barranco‐Gil, D. (2022) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2021-0403 · Cited by 70
Sanders, D., Taylor, R. J., Myers, T., & Akubat, I. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001910 · Cited by 52
Validity and Reliability of the Cycleops Hammer Cycle Ergometer
Lillo-Beviá, J. R., & Pallarés, J. G. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2017-0403 · Cited by 42
Yang, W., Park, S., Kim, T., Jeon, H.-J., Heine, O., & Gehlert, S. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1147321 · Cited by 40
“5–1% according to themanufacturer and previous studies (Bouillod et al., 2017; Nimmerichter et al., 2017; Montalvo-Pérez et al., 2021).”
Using Field Based Data to Model Sprint Track Cycling Performance
Ferguson, H. A., Harnish, C., & Chase, J. G. (2021) · Sports Medicine - Open · doi:10.1186/s40798-021-00310-0 · Cited by 37
Metadata
- Authors
- Bouillod, A., Pinot, J., Soto-Romero, G., Bertucci, W., & Grappe, F.
- Affiliations
- Laboratoire d'Analyse et d'Architecture des Systèmes (FR)
- Laboratoire Culture, Sport, Santé, Société (FR)
- Université de Reims Champagne-Ardenne (FR)
- Corresponding author
- Bouillod, Anthony
- Venue
- International Journal of Sports Physiology and Performance
- Publisher
- Human Kinetics
- Published
- 2017-09
- Volume
- 12
- Issue
- 8
- Pages
- 1023-1030
- ISSN
- 1555-0265 (ISSN-L)
- 1555-0273
- OpenAlex
- W2567421351
- Semantic Scholar
- ed54e6a7ea03b55f6bf12ac2a2b7297cbe73b144
- Cited by
- 49
- References
- 37
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 2 · 2023: 3 · 2022: 6 · 2021: 9 · 2020: 8 · 2019: 5 · 2018: 5 · 2017: 3
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- other-oa
- Locations
- International Journal of Sports Physiology and Performance (publishedVersion, other-oa)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- power meters, stage, SRM, power output measurement, measurement validity, measurement sensitivity, reproducibility, robustness, vibration interference, cycling, sprint test, incremental test, gear ratio
- MeSH terms
- Bicycling, Equipment Design, Exercise Test, Humans, Male, Sensitivity and Specificity, Reproducibility of Results, Ergometry, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.