The Validity of Consumer-Level Activity Monitors in Healthy Older Adults in Free-Living Conditions
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Consumer-level activity monitors, such as Fitbit and Misfit devices, are a popular and low-cost means of measuring physical activity. This study aims to compare the accuracy of step counts from two consumer-level activity monitors against two reference devices in healthy, community-dwelling older adults in free-living conditions. Twenty-five older adults (aged 65–84) simultaneously wore 5 devices (e.g., Misfit Shine and Fitbit Charge HR) over 7 consecutive days. All consumer-level activity monitors positively correlated with reference devices (p < .001). There was also substantial to near perfect agreement between all consumer-level activity monitors and reference devices. Compared to the ActiGraph GT3X+, the waist-worn Misfit Shine displayed the highest agreement amongst the devices worn (ICC = 0.96, 95% 0.91 to 0.99). The wrist-worn devices showed poorer agreement to reference devices. Future research needs to consider that not all consumer-level activity monitors are equal in terms of accuracy, design, and function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 1×
“However, until we understand if 8 the specifications within a brands activity monitors are similar, the validity and reliability of 9 new devices to the market need to be confirmed (Evenson et al., 2015).”
BackgroundA Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical activity dose-response effects on outcomes of depression and anxiety
DUNN, A. L., TRIVEDI, M. H., & O???NEAL, H. A. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200106001-00027 · Cited by 816
Hupin, D., Roche, F., Gremeaux, V., Chatard, J.-C., Oriol, M., Gaspoz, J.-M., Barthélémy, J.-C., & Edouard, P. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-094306 · Cited by 565 · cited 1×
“…activity are well established, being able to prevent or delay the onset 3 of a variety of chronic diseases (Singh, 2002), as well as improving physical fitness, reducing 4 depression, anxiety, and mortality (Dunn, Trivedi, & O’Neal, 2001; Hupin et al., 2015; 5 Warburton, Nicol, & Bredin, 2006).”
BackgroundExercise comes of age: rationale and recommendations for a geriatric exercise prescription
Singh, M. A. F. (2002) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/57.5.m262 · Cited by 485
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · cited 2×
“In line with the findings from a sample of healthy adults (BodyMedia 10 SenseWear; ICC =0.90) (Ferguson et al., 2015), the wrist worn Misfit Shine showed excellent 11 agreement compared to reference devices.”
MethodResultInfluentialValidity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401
Reliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360
Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[20,21,29,32,34,36,38,45,53,64-82] Wrist Discontinued 2015 Charge HR Fitbit”
BackgroundAccuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“A total of 13 studies examined Fitbit accuracy for step count in free-living conditions (20 accuracy comparisons; Multimedia Appendix 3) [36,52-63].”
BackgroundStraiton, N., Alharbi, M., Bauman, A., Neubeck, L., Gullick, J., Bhindi, R., & Gallagher, R. (2018) · Maturitas · doi:10.1016/j.maturitas.2018.03.016 · Cited by 147
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O'Flynn, B. (2019) · JMIR mHealth and uHealth · doi:10.2196/13084 · Cited by 139
“Farina and Lowry [20] compared the accuracy of step counts from two consumer-level activity monitors (Misfit Shine on both wrist and waist, and Fitbit Charge HR on the wrist) against two waist-worn reference devices (ActiGraph GT3X+ and New Lifestyle NL2000i) in healthy, community-dwelling older adults in free-living…”
BackgroundCollins, J. E., Yang, H. Y., Trentadue, T. P., Gong, Y., & Losina, E. (2019) · PLOS ONE · doi:10.1371/journal.pone.0211231 · Cited by 55
“[40] compared the Fitbit Charge HR to the hip-worn ActiGraph GT3X+ in a population of older adults in free-living conditions.”
BackgroundResult
Metadata
- Authors
- Farina, N., & Lowry, R. G.
- Venue
- Journal of Aging and Physical Activity
- Publisher
- Human Kinetics
- Published
- 2018-01-01
- Volume
- 26
- Issue
- 1
- Pages
- 128-135
- ISSN
- 1063-8652 (ISSN-L)
- 1543-267X
- OpenAlex
- W2618060007
- Cited by
- 45
- References
- 12
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Validity of Consumer-Level Activity Monitors in Healthy Older Adults in Free-Living Conditions. https://app.cochat.ai/papers/10.1123/japa.2016-0344
- The paper
- Farina, N., & Lowry, R. G. (2018). The Validity of Consumer-Level Activity Monitors in Healthy Older Adults in Free-Living Conditions. Journal of Aging and Physical Activity. https://doi.org/10.1123/japa.2016-0344
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.