Relative Validity of 3 Accelerometer Models for Estimating Energy Expenditure During Light Activity
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background: With physical inactivity inextricably linked to the increasing prevalence of obesity, there is a need for validated methods that measure free-living energy expenditure (EE) within sedentary environments. While accelerometers enable these measurements, few studies have compared device accuracy in such settings. The aim of this study was to investigate the relative validity of the Actigraph, RT3 and SenseWear Armband (SWA). Methods: Twenty-three (11 male, 12 female) participants (age: 25.3 ± 6.3 yr; BMI: 22.6 ± 2.7) wore 3 accelerometers at designated sites during a 4-hour stay in the Whole Room Calorimeter (WRC). Participants performed 2 10-minute bouts of light-intensity exercise (stepping and stationary cycling) and engaged in unstructured sedentary activities. EE estimated by accelerometers was compared with WRC EE derived from measurements of gaseous exchange. Results: The Actigraph and SWA both accurately estimated EE during the stepping exercise. EE estimated by the RT3 during stepping was significantly lower than the WRC value (31.2% ± 15.6%, P < .001). All accelerometers underestimated cycling and unstructured activity EE over the trial period (P < .001). Conclusions: The Actigraph and SWA are both valid tools for quantifying EE during light-intensity stepping. These results provide further valuable information on how accelerometer devices may be appropriately used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The BUGS project: evolution, critique and future directions
Lunn, D., Spiegelhalter, D., Thomas, A., & Best, N. (2009) · Statistics in Medicine · doi:10.1002/sim.3680 · Cited by 1,876
Objectively Measured Sedentary Time, Physical Activity, and Metabolic Risk
Healy, G. N., Wijndaele, K., Dunstan, D. W., Shaw, J. E., Salmon, J., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-1795 · Cited by 1,100
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Lubans, D. R., Hesketh, K., Cliff, D. P., Barnett, L. M., Salmon, J., Dollman, J., Morgan, P. J., Hills, A. P., & Hardy, L. L. (2011) · Obesity Reviews · doi:10.1111/j.1467-789x.2011.00896.x · Cited by 282
Cited by
Physical Activity Early after Stroke and Its Association to Functional Outcome 3 Months Later
Askim, T., Bernhardt, J., Salvesen, Ø., & Indredavik, B. (2014) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2013.12.011 · Cited by 91
Surveillance of Youth Physical Activity and Sedentary Behavior with Wrist Accelerometry
Kim, Y., Hibbing, P., Saint-Maurice, P. F., Ellingson, L. D., Hennessy, E., Wolff-Hughes, D. L., Perna, F. M., & Welk, G. J. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2017.01.012 · Cited by 29
Rockette-Wagner, B., Storti, K. L., Dabelea, D., Edelstein, S., Florez, H., Franks, P. W., Montez, M. G., Pomeroy, J., & Kriska, A. M. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2016.10.007 · Cited by 21
Feehan, L. M., Goldsmith, C. H., Leung, A. Y. F., & Li, L. C. (2016) · Physiotherapy Canada · doi:10.3138/ptc.2015-12 · Cited by 20
Sartor, F., Ditali, L., Sirtori, G., Morano, T., Lancia, F., Di Marco, A., Izzicupo, P., Di Baldassarre, A., Gallina, S., Pesce, M., et al. (2025) · Healthcare · doi:10.3390/healthcare13192471 · Cited by 2
Metadata
- Authors
- Wetten, A. A., Batterham, M., Tan, S. Y., & Tapsell, L.
- Venue
- Journal of Physical Activity and Health
- Publisher
- Human Kinetics
- Published
- 2014-03
- Volume
- 11
- Issue
- 3
- Pages
- 638-647
- ISSN
- 1543-3080 (ISSN-L)
- 1543-5474
- OpenAlex
- W2111714306
- Cited by
- 65
- References
- 12
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relative Validity of 3 Accelerometer Models for Estimating Energy Expenditure During Light Activity. https://app.cochat.ai/papers/10.1123/jpah.2011-0167
- The paper
- Wetten, A. A., Batterham, M., Tan, S. Y., & Tapsell, L. (2014). Relative Validity of 3 Accelerometer Models for Estimating Energy Expenditure During Light Activity. Journal of Physical Activity and Health. https://doi.org/10.1123/jpah.2011-0167
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.