Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
High-sensitivity total-field atomic magnetometer enables brain-activity measurements in unshielded Earth’s field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“From a practical standpoint, technological challenges including shielding, noise, cost, and scalability limitations in SQUID, OPM, TMR, and magnetoelectric systems—though currently addressed in several prototype systems—remain significant barriers to scalable clinical translation [23,24,25,26,27,46,47].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [47]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [35]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments (35, 36) due to the magnetic field noise from surroundings. Despite there being several works on unshielded biomagnetic signal measurements (35, 37), these shielded or unshielded measurements normally require the participant to remain still during the measurement.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [35]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Both technologies have also proven sufficiently sensitive for unshielded MEG and brain source localization using an array of scalar OPMs in the presence of a large background field (280–284).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [281]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [35]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 5×
“4 of 8 strong among all the signals detected with EEG and MEG (40).”
BackgroundInfluentialA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377 · cited 7×
“The MEG system typically uses two different kinds of magne tometers as the magnetic sensors, the superconducting quantum interference devices (SQUIDs) (15–17) or the optically pumped atomic magnetometers (OPMs) (18–25).”
MethodInfluentialHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Magnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
EEG and MEG: Relevance to Neuroscience
Lopes da Silva, F. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.017 · Cited by 900
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Research works printed but not linked: 3
- S. J. Seltzer Developments in alkali-metal atomic magnetometry thesis Princeton University (2008).
- M. E. Limes E. L. Foley T. W. Kornack S. Caliga S. McBride A. Braun W. Lee V. G. Lucivero M. V. Romalis Total-field atomic gradiometer for unshielded portable magnetoencephalography arXiv:2001.03534 [physics.med-ph] (7 January 2020). · arXiv
- J. Bork H.-D. Hahlbohm R. Klein A. Schnabel The 8-layered magnetically shielded room of the PTB: Design and construction in Biomag2000: Proceedings of the 12th International Conference on Biomagnetism (University of Technology 2001).
Cited by
Portable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257
Criticality-Enhanced Quantum Sensing via Continuous Measurement
Ilias, T., Yang, D., Huelga, S. F., & Plenio, M. B. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.010354 · Cited by 208
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments ( 35 , 36 ) due to the magnetic field noise from surroundings.”
Self-citationDiamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement
Zhang, C., Shagieva, F., Widmann, M., Kübler, M., Vorobyov, V., Kapitanova, P., Nenasheva, E., Corkill, R., Rhrle, O., Nakamura, K., et al. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.064075 · Cited by 137
Sensitive magnetometry in challenging environments
Fu, K. C., Iwata, G. Z., Wickenbrock, A., & Budker, D. (2020) · AVS Quantum Science · doi:10.1116/5.0025186 · Cited by 132
Metadata
- Authors
- Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., Zheng, Z., Zhang, X., Chen, J., & Guo, H.
- Affiliations
- National University of Defense Technology (CN)
- Peking University (CN)
- Beijing University of Posts and Telecommunications (CN)
- Corresponding author
- Zhang, Rui
- Xiao, Wei
- Wu, Teng
- Guo, Hong
- ORCID
- Venue
- Science Advances
- Published
- 2020-06-12
- Volume
- 6
- Issue
- 24
- Pages
- eaba8792-eaba8792
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC7292643
- OpenAlex
- W3035564083
- Cited by
- 222
- References
- 44
- Citations by year
- 2026: 33 · 2025: 49 · 2024: 40 · 2023: 42 · 2022: 20 · 2021: 32 · 2020: 6
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Science Advances (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (61531003, 61225003, 91436210, 61571018)
- Peking University
- National Institute of Metrology, China
- National Science Fund for Distinguished Young Scholars (61225003)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- optically pumped atomic magnetometer, geomagnetic field, alpha rhythm, auditory evoked magnetic fields, epilepsy diagnosis, brain activity recording
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers. https://app.cochat.ai/papers/10.1126/sciadv.aba8792
- The paper
- Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., Zheng, Z., Zhang, X., Chen, J., & Guo, H. (2020). Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers. Science Advances. https://doi.org/10.1126/sciadv.aba8792
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.