Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
High-sensitivity total-field atomic magnetometer enables brain-activity measurements in unshielded Earth’s field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“From a practical standpoint, technological challenges including shielding, noise, cost, and scalability limitations in SQUID, OPM, TMR, and magnetoelectric systems—though currently addressed in several prototype systems—remain significant barriers to scalable clinical translation [23,24,25,26,27,46,47].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [47]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [35]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments (35, 36) due to the magnetic field noise from surroundings. Despite there being several works on unshielded biomagnetic signal measurements (35, 37), these shielded or unshielded measurements normally require the participant to remain still during the measurement.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [35]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Both technologies have also proven sufficiently sensitive for unshielded MEG and brain source localization using an array of scalar OPMs in the presence of a large background field (280–284).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [281]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [35]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 5×
“4 of 8 strong among all the signals detected with EEG and MEG (40).”
BackgroundInfluentialA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377 · cited 7×
“The MEG system typically uses two different kinds of magne tometers as the magnetic sensors, the superconducting quantum interference devices (SQUIDs) (15–17) or the optically pumped atomic magnetometers (OPMs) (18–25).”
MethodInfluentialHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Magnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
EEG and MEG: Relevance to Neuroscience
Lopes da Silva, F. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.017 · Cited by 900
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Hari, R., Aittoniemi, K., Järvinen, M. L., Katila, T., & Varpula, T. (1980) · Experimental Brain Research · doi:10.1007/bf00237543 · Cited by 427 · cited 1×
“The AEF signal originates from the auditory evoked electric potential generated within the brain while an auditory stimulus is presented (42).”
BackgroundSubpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415 · cited 1×
“A general tendency within the MEG community is replacing SQUID with noncryogenic highsensitivity OPM as the magnetic sensor (18–25), considering that the sensitivity of the OPM sensor has been comparable with that of the most sensitive SQUID sensor and the miniaturization has become much improved (26, 27).”
MethodMEG: An Introduction to Methods
(2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 408
Intracranial EEG and human brain mapping
Lachaux, J. P., Rudrauf, D., & Kahane, P. (2003) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2004.01.018 · Cited by 331
Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300 · cited 9×
“Compared with its electric signal detection–based counterpart, i.e., scalp electroencephalography (EEG) (4, 5), MEG has a higher spatial resolution due to the nearly homogeneous magnetic permeability of biological tissues (6).”
BackgroundInfluentialMagnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
(2013) · doi:10.1017/cbo9780511846380 · Cited by 286
Portable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257
King, J. R., Faugeras, F., Gramfort, A., Schurger, A., El Karoui, I., Sitt, J. D., Rohaut, B., Wacongne, C., Labyt, E., Bekinschtein, T., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.013 · Cited by 197 · cited 1×
“MEG has various applications in neuroscience (8), cognitive science (9), and especially in the diagnosis of brain symptoms such as epilepsy presurgical evaluation (10), Alzheimer’s disease (11), Parkinson’s disease (12), traumatic brain injury (13), and multiple sclerosis (14).”
BackgroundA microfabricated optically-pumped magnetic gradiometer
Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017) · Applied Physics Letters · doi:10.1063/1.4974349 · Cited by 179
Microtesla MRI of the human brain combined with MEG
Zotev, V. S., Matlashov, A. N., Volegov, P. L., Savukov, I. M., Espy, M. A., Mosher, J. C., Gomez, J. J., & Kraus, R. H. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.06.007 · Cited by 175 · cited 1×
“The unshielded MEG system also makes it possible to be combined with the lowfield magnetic resonance imaging system (16) and provides a convenient way for the coregistration in locating and imaging the brain activities.”
BackgroundMulti-channel atomic magnetometer for magnetoencephalography: A configuration study
Kim, K., Begus, S., Xia, H., Lee, S.-K., Jazbinsek, V., Trontelj, Z., & Romalis, M. V. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.040 · Cited by 170
MEG Predicts Epileptic Zone in Lesional Extrahippocampal Epilepsy: 12 Pediatric Surgery Cases
Otsubo, H., Ochi, A., Elliott, I., Chuang, S. H., Rutka, J. T., Jay, V., Aung, M., Sobel, D. F., & Snead, O. C. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.16701.x · Cited by 161
Visually Evoked Magnetic Fields of the Human Brain
Brenner, D., Williamson, S. J., & Kaufman, L. (1975) · Science · doi:10.1126/science.170683 · Cited by 161
Neuromagnetic Evidence of Abnormal Movement-Related Beta Desynchronization in Parkinson's Disease
Heinrichs-Graham, E., Wilson, T. W., Santamaria, P. M., Heithoff, S. K., Torres-Russotto, D., Hutter-Saunders, J. A. L., Estes, K. A., Meza, J. L., Mosley, R. L., & Gendelman, H. E. (2014) · Cerebral Cortex · doi:10.1093/cercor/bht121 · Cited by 160 · cited 1×
“MEG has various applications in neuroscience (8), cognitive science (9), and especially in the diagnosis of brain symptoms such as epilepsy presurgical evaluation (10), Alzheimer’s disease (11), Parkinson’s disease (12), traumatic brain injury (13), and multiple sclerosis (14).”
BackgroundMulti-sensor magnetoencephalography with atomic magnetometers
Johnson, C. N., Schwindt, P. D. D., & Weisend, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/17/6065 · Cited by 131
Alpha rhythms: noise, dynamics and models
Lopes, F. H. D. S., Pijn, J. P. M., Velis, D. N., & Nijssen, P. C. G. (1997) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00767-8 · Cited by 129
Nonlinear magneto-optical rotation with amplitude modulated light
Gawlik, W., Krzemień, L., Pustelny, S., Sangla, D., Zachorowski, J., Graf, M., Sushkov, A. O., & Budker, D. (2006) · Applied Physics Letters · doi:10.1063/1.2190457 · Cited by 107
López-Sanz, D., Bruña, R., Garcés, P., Camara, C., Serrano, N., Rodríguez-Rojo, I. C., Delgado, M. L., Montenegro, M., López-Higes, R., Yus, M., et al. (2016) · Scientific Reports · doi:10.1038/srep37685 · Cited by 103
Tewarie, P., Schoonheim, M. M., Schouten, D. I., Polman, C. H., Balk, L. J., Uitdehaag, B. M. J., Geurts, J. J. G., Hillebrand, A., Barkhof, F., & Stam, C. J. (2015) · Human Brain Mapping · doi:10.1002/hbm.22650 · Cited by 99 · cited 1×
“MEG has various applications in neuroscience (8), cognitive science (9), and especially in the diagnosis of brain symptoms such as epilepsy presurgical evaluation (10), Alzheimer’s disease (11), Parkinson’s disease (12), traumatic brain injury (13), and multiple sclerosis (14).”
BackgroundWikswo, J. P., Gevins, A. S., & Williamson, S. J. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90169-v · Cited by 96 · cited 9×
“Compared with its electric signal detection–based counterpart, i.e., scalp electroencephalography (EEG) (4, 5), MEG has a higher spatial resolution due to the nearly homogeneous magnetic permeability of biological tissues (6).”
BackgroundInfluentialMagnetometry with millimeter-scale antirelaxation-coated alkali-metal vapor cells
Balabas, M. V., Budker, D., Kitching, J. E., Schwindt, P. D. D., & Stalnaker, J. E. (2006) · Journal of the Optical Society of America B · doi:10.1364/josab.23.001001 · Cited by 93 · cited 1×
“Although the relaxation rate of a paraffincoated cesium cell with a diameter of 3 mm is comparable to that used in our experiment (43), decreasing the size of the vapor cell would markedly decrease the number of atoms that involves in the magnetic sensing, which, in turn, degrades the sensitivity of the magnetometer.”
MethodBen-Kish, A., & Romalis, M. V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.193601 · Cited by 87
Kamada, K., Sato, D., Ito, Y., Natsukawa, H., Okano, K., Mizutani, N., & Kobayashi, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.026601 · Cited by 74
Magnetoencephalography in Focal Epilepsy
Baumgartner, C., Pataraia, E., Lindinger, G., & Deecke, L. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01533.x · Cited by 59
Recent Progress in Optically Pumped Magnetometers
Alexandrov, E. B. (2003) · Physica Scripta · doi:10.1238/physica.topical.105a00027 · Cited by 56
Magnetoencephalography of Epilepsy with a Microfabricated Atomic Magnetrode
Alem, O., Benison, A. M., Barth, D. S., Kitching, J., & Knappe, S. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.3495-14.2014 · Cited by 52 · cited 2×
“These advantages make it possible to construct a wearable and movable MEG system for noninvasive longterm observations of the patients with brain symptoms, such as epilepsy, to capture the infrequent epileptiform events (28).”
BackgroundMethodCharacterization of high-temperature performance of cesium vapor cells with anti-relaxation coating
Li, W., Balabas, M. V., Peng, X., Pustelny, S., Wickenbrock, A., Guo, H. M., & Budker, D. (2017) · Journal of Applied Physics · doi:10.1063/1.4976017 · Cited by 49
Self-citationAlhourani, A., Wozny, T. A., Krishnaswamy, D., Pathak, S., Walls, S. A., Ghuman, A. S., Krieger, D., Okonkwo, D. O., Richardson, R. M., & Niranjan, A. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00513.2016 · Cited by 45
Magnetoencephalography: From Signals to Dynamic Cortical Networks
Taylor, M. J., Urbain, C. M., & Pang, E. E. W. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5 · Cited by 18 · cited 1×
“To solve these issues, the head movement of the person should be constantly monitored and taken as input parameters for data after processing (46).”
MethodSeki, Y., Miyashita, T., Kandori, A., Maki, A., & Koizumi, H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.10.107001 · Cited by 17
Frequency Response of a Close-Loop Bell-Bloom Magnetometer
Zhang, R., Pang, B., Li, W., Yang, Y., Chen, J., Peng, X., & Guo, H. M. (2018) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2018.8597470 · Cited by 12 · cited 1×
“Both of the two OPMs are working in the closedloop mode, which provides a larger bandwidth and better performance in reducing the commonmode noise com pared with the openloop mode (37, 38).”
MethodSelf-citationZhang, R., Pang, B., Ding, Y., Li, W., Chen, J., Peng, X., & Guo, H. M. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8856049 · Cited by 3 · cited 6×
“In our system, instead, the environ ment magnetic noise is monitored with the bottom OPM sensor and then compensated by automatically controlling the current applied to the coils along the vertical direction (see Materials and Methods for details).”
MethodInfluentialSelf-citation
Research works printed but not linked: 3
- S. J. Seltzer Developments in alkali-metal atomic magnetometry thesis Princeton University (2008).
- M. E. Limes E. L. Foley T. W. Kornack S. Caliga S. McBride A. Braun W. Lee V. G. Lucivero M. V. Romalis Total-field atomic gradiometer for unshielded portable magnetoencephalography arXiv:2001.03534 [physics.med-ph] (7 January 2020). · arXiv
- J. Bork H.-D. Hahlbohm R. Klein A. Schnabel The 8-layered magnetically shielded room of the PTB: Design and construction in Biomag2000: Proceedings of the 12th International Conference on Biomagnetism (University of Technology 2001).
Cited by
Portable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257
Criticality-Enhanced Quantum Sensing via Continuous Measurement
Ilias, T., Yang, D., Huelga, S. F., & Plenio, M. B. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.010354 · Cited by 208
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments ( 35 , 36 ) due to the magnetic field noise from surroundings.”
Self-citationDiamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement
Zhang, C., Shagieva, F., Widmann, M., Kübler, M., Vorobyov, V., Kapitanova, P., Nenasheva, E., Corkill, R., Rhrle, O., Nakamura, K., et al. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.064075 · Cited by 137
Sensitive magnetometry in challenging environments
Fu, K. C., Iwata, G. Z., Wickenbrock, A., & Budker, D. (2020) · AVS Quantum Science · doi:10.1116/5.0025186 · Cited by 132
Metadata
- Authors
- Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., Zheng, Z., Zhang, X., Chen, J., & Guo, H.
- Affiliations
- National University of Defense Technology (CN)
- Peking University (CN)
- Beijing University of Posts and Telecommunications (CN)
- Corresponding author
- Zhang, Rui
- Xiao, Wei
- Wu, Teng
- Guo, Hong
- ORCID
- Venue
- Science Advances
- Published
- 2020-06-12
- Volume
- 6
- Issue
- 24
- Pages
- eaba8792-eaba8792
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC7292643
- OpenAlex
- W3035564083
- Cited by
- 222
- References
- 44
- Citations by year
- 2026: 33 · 2025: 49 · 2024: 40 · 2023: 42 · 2022: 20 · 2021: 32 · 2020: 6
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Science Advances (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (61531003, 61225003, 91436210, 61571018)
- Peking University
- National Institute of Metrology, China
- National Science Fund for Distinguished Young Scholars (61225003)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- optically pumped atomic magnetometer, geomagnetic field, alpha rhythm, auditory evoked magnetic fields, epilepsy diagnosis, brain activity recording
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.