The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Wirelessly controlled, bioresorbable drug delivery device with active valves that exploit electrochemically triggered crevice corrosion
Open accessAbstract
Bioresorbable drug release platforms offer advanced treatment for hormone imbalances, malignant cancers, and diabetic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
Makadia, H. K., & Siegel, S. J. (2011) · Polymers · doi:10.3390/polym3031377 · Cited by 4,816
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Pancreatic regulation of glucose homeostasis.
Röder, P. V., Wu, B., Liu, Y., & Han, W. (2016) · Experimental & Molecular Medicine · doi:10.1038/emm.2016.6 · Cited by 985
Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0196-2 · Cited by 496
Self-citation
Cited by
Fully implantable and bioresorbable cardiac pacemakers without leads or batteries
Choi, Y. S., Yin, R. T., Pfenniger, A., Koo, J., Avila, R., Benjamin Lee, K., Chen, S. W., Lee, G., Li, G., Qiao, Y., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00948-x · Cited by 361
Self-citationA transient, closed-loop network of wireless, body-integrated devices for autonomous electrotherapy
Choi, Y. S., Jeong, H., Yin, R. T., Avila, R., Pfenniger, A., Yoo, J., Lee, J. Y., Tzavelis, A., Lee, Y. J., Chen, S. W., et al. (2022) · Science · doi:10.1126/science.abm1703 · Cited by 267
Self-citation
Metadata
- Authors
- Koo, J., Kim, S. B., Choi, Y. S., Xie, Z., Bandodkar, A. J., Khalifeh, J., Yan, Y., Kim, H., Pezhouh, M. K., Doty, K., Lee, G., Chen, Y.-Y., Lee, S. M., D’Andrea, D., Jung, K., Lee, K., Li, K., Jo, S., Wang, H., Kim, J.-H., Kim, J., Choi, S.-G., Jang, W. J., Oh, Y. S., Park, I., Kwak, S. S., Park, J.-H., Hong, D., Feng, X., Lee, C.-H., Banks, A., Leal, C., Lee, H. M., Huang, Y., Franz, C. K., Ray, W. Z., MacEwan, M., Kang, S.-K., & Rogers, J. A.
- Venue
- Science Advances
- Published
- 2020-08-28
- Volume
- 6
- Issue
- 35
- Pages
- eabb1093-eabb1093
- ISSN
- 2375-2548 (ISSN-L)
- OpenAlex
- W3081982012
- Cited by
- 160
- References
- 4
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wirelessly controlled, bioresorbable drug delivery device with active valves that exploit electrochemically triggered crevice corrosion. https://app.cochat.ai/papers/10.1126/sciadv.abb1093
- The paper
- Koo, J., Kim, S. B., Choi, Y. S., Xie, Z., Bandodkar, A. J., Khalifeh, J., Yan, Y., Kim, H., Pezhouh, M. K., Doty, K., Lee, G., Chen, Y.-Y., Lee, S. M., D’Andrea, D., Jung, K., Lee, K., Li, K., Jo, S., Wang, H., . . . Rogers, J. A. (2020). Wirelessly controlled, bioresorbable drug delivery device with active valves that exploit electrochemically triggered crevice corrosion. Science Advances. https://doi.org/10.1126/sciadv.abb1093
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.