A transient, closed-loop network of wireless, body-integrated devices for autonomous electrotherapy

Open access
Choi, Yeon Sik, Jeong, Hyoyoung, Yin, Rose T., Avila, Raudel, Pfenniger, Anna, Yoo, Jaeyoung, Lee, Jong Yoon, Tzavelis, Andreas, Lee, Young Joong, Chen, Sheena W., Knight, Helen S., Kim, Seungyeob, Ahn, Hak-Young, Wickerson, Grace, Vázquez-Guardado, Abraham, Higbee-Dempsey, Elizabeth, Russo, Bender A., Napolitano, Michael A., Holleran, Timothy J., Razzak, Leen Abdul, Miniovich, Alana N., Lee, Geumbee, Geist, Beth, Kim, Brandon, Han, Shuling, Brennan, Jaclyn A., Aras, Kedar, Kwak, Sung Soo, Kim, Joohee, Waters, Emily Alexandria, Yang, Xiangxing, Burrell, Amy, San Chun, Keum, Liu, Claire, Wu, Changsheng, Rwei, Alina Y., Spann, Alisha N., Banks, Anthony, Johnson, David, Zhang, Zheng Jenny, Haney, Chad R., Jin, Sung Hun, Sahakian, Alan Varteres, Huang, Yonggang, Trachiotis, Gregory D., Knight, Bradley P., Arora, Rishi K., Efimov, Igor R., Rogers, John A.·2022·Science

Abstract

Temporary postoperative cardiac pacing requires devices with percutaneous leads and external wired power and control systems. This hardware introduces risks for infection, limitations on patient mobility, and requirements for surgical extraction procedures. Bioresorbable pacemakers mitigate some of these disadvantages, but they demand pairing with external, wired systems and secondary mechanisms for control. We present a transient closed-loop system that combines a time-synchronized, wireless network of skin-integrated devices with an advanced bioresorbable pacemaker to control cardiac rhythms, track cardiopulmonary status, provide multihaptic feedback, and enable transient operation with minimal patient burden. The result provides a range of autonomous, rate-adaptive cardiac pacing capabilities, as demonstrated in rat, canine, and human heart studies. This work establishes an engineering framework for closed-loop temporary electrotherapy using wirelessly linked, body-integrated bioelectronic devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/science.abm1703

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 267

Metadata

Authors
Choi, Y. S., Jeong, H., Yin, R. T., Avila, R., Pfenniger, A., Yoo, J., Lee, J. Y., Tzavelis, A., Lee, Y. J., Chen, S. W., Knight, H. S., Kim, S., Ahn, H.-Y., Wickerson, G., Vázquez-Guardado, A., Higbee-Dempsey, E., Russo, B. A., Napolitano, M. A., Holleran, T. J., Razzak, L. A., Miniovich, A. N., Lee, G., Geist, B., Kim, B., Han, S., Brennan, J. A., Aras, K., Kwak, S. S., Kim, J., Waters, E. A., Yang, X., Burrell, A., San Chun, K., Liu, C., Wu, C., Rwei, A. Y., Spann, A. N., Banks, A., Johnson, D., Zhang, Z. J., Haney, C. R., Jin, S. H., Sahakian, A. V., Huang, Y., Trachiotis, G. D., Knight, B. P., Arora, R. K., Efimov, I. R., & Rogers, J. A.
Venue
Science
Published
2022-05-27
Volume
376
Issue
6596
Pages
1006-1012
ISSN
  • 0036-8075 (ISSN-L)
  • 1095-9203
OpenAlex
W4281553981
Cited by
267
References
40
FWCI
14.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A transient, closed-loop network of wireless, body-integrated devices for autonomous electrotherapy. https://app.cochat.ai/papers/10.1126/science.abm1703
The paper
Choi, Y. S., Jeong, H., Yin, R. T., Avila, R., Pfenniger, A., Yoo, J., Lee, J. Y., Tzavelis, A., Lee, Y. J., Chen, S. W., Knight, H. S., Kim, S., Ahn, H.-Y., Wickerson, G., Vázquez-Guardado, A., Higbee-Dempsey, E., Russo, B. A., Napolitano, M. A., Holleran, T. J., . . . Rogers, J. A. (2022). A transient, closed-loop network of wireless, body-integrated devices for autonomous electrotherapy. Science. https://doi.org/10.1126/science.abm1703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.