Electronics with shape actuation for minimally invasive spinal cord stimulation
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Electronics that change shape inside the body enable keyhole surgery of spinal implants that can treat severe pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Although the second type, thin film flexible electrical stimulators, are available in non-inserted way on the cortical surface to reduce damage to brain tissue, the array density of such devices is much smaller than the first, and they are more suitable for stimulation of relatively large brain areas.[545,546]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [545]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,334
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Self-citationWhitesides, G. M. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201800907 · Cited by 850
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738 · cited 1×
“These devices are advancing our understanding of the neural networks (19, 20) and are beginning to be translated to the clinic (21).”
BackgroundGill, M. L., Grahn, P. J., Calvert, J. S., Linde, M. B., Lavrov, I. A., Strommen, J. A., Beck, L. A., Sayenko, D. G., Van Straaten, M. G., Drubach, D. I., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0175-7 · Cited by 574
Determining the optimal PDMS–PDMS bonding technique for microfluidic devices
Eddings, M. A., Johnson, M. A., & Gale, B. K. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/067001 · Cited by 567 · cited 1×
“Initially, fabrication of the device fluidics was explored using siliconesilicone bonding via O2 plasma activation, a common technique used in silicone fabrication (25, 26), but this option does not enable the device to hold high-enough internal pressures.”
MethodNext-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Self-citation
Research works printed but not linked: 1
- S. Wang A. Kallur A. Goshu Organic Photonic Materials and Devices XIII (International Society for Optics and Photonics 2011) vol. 7935 p. 79350M.
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Skin-inspired, sensory robots for electronic implants
Zhang, L., Xing, S., Yin, H., Weisbecker, H., Tran, H. T., Guo, Z., Han, T., Wang, Y., Liu, Y., Wu, Y., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48903-z · Cited by 175
Wearable and Implantable Soft Robots
Yin, S., Yao, D. R., Song, Y., Heng, W., Ma, X., Han, H., & Gao, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00513 · Cited by 173
Bioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 183
Kim, S., Baek, S., Sluyter, R., Konstantinov, K., Kim, J. H., Kim, S., & Kim, J. H. (2023) · EcoMat · doi:10.1002/eom2.12356 · Cited by 106
Metadata
- Authors
- Woodington, B. J., Curto, V. F., Yu, Y.-L., Martínez-Domínguez, H., Coles, L., Malliaras, G. G., Proctor, C. M., & Barone, D. G.
- Affiliations
- University of Cambridge (GB)
- Tri-Service General Hospital (TW)
- Tecnológico Nacional de México (MX)
- Corresponding author
- Woodington, Ben J.
- Curto, Vincenzo F.
- Malliaras, George G.
- Proctor, Christopher M.
- Barone, Damiano G.
- ORCID
- Venue
- Science Advances
- Published
- 2021-06-25
- Volume
- 7
- Issue
- 26
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC8232905
- OpenAlex
- W3167842833
- Cited by
- 75
- References
- 32
- Citations by year
- 2026: 13 · 2025: 16 · 2024: 18 · 2023: 16 · 2022: 10 · 2021: 2
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Science Advances (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- Cambridge University Engineering Department Publications Database (submittedVersion)
- Apollo (cc-by)
- Funders
- Engineering and Physical Sciences Research Council
- Biotechnology and Biological Sciences Research Council
- National Institute for Health Research
- European Commission
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- spinal cord stimulation, neuromodulation, flexible electronics, percutaneous implantation, minimally invasive implantation, soft lithography, photolithography, fluidic channels, bioelectronic devices, cadaveric model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.