The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Abstract
Boron-doped silicon nanowires (SiNWs) were used to create highly sensitive, real-time electrically based sensors for biological and chemical species. Amine- and oxide-functionalized SiNWs exhibit pH-dependent conductance that was linear over a large dynamic range and could be understood in terms of the change in surface charge during protonation and deprotonation. Biotin-modified SiNWs were used to detect streptavidin down to at least a picomolar concentration range. In addition, antigen-functionalized SiNWs show reversible antibody binding and concentration-dependent detection in real time. Lastly, detection of the reversible binding of the metabolic indicator Ca 2+ was demonstrated. The small size and capability of these semiconductor nanowires for sensitive, label-free, real-time detection of a wide range of chemical and biological species could be exploited in array-based screening and in vivo diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
Room-temperature transistor based on a single carbon nanotube
Tans, S. J., Verschueren, A. R. M., & Dekker, C. (1998) · Nature · doi:10.1038/29954 · Cited by 5,425
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Iler, K. (1979) · Medical Entomology and Zoology · Cited by 5,030
Indium phosphide nanowires as building blocks for nanoscale electronic and optoelectronic devices
Duan, X., Huang, Y., Cui, Y., Wang, J., & Lieber, C. M. (2001) · Nature · doi:10.1038/35051047 · Cited by 3,354
Self-citationFunctional Nanoscale Electronic Devices Assembled Using Silicon Nanowire Building Blocks
Cui, Y., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5505.851 · Cited by 3,258
Self-citationDirected Assembly of One-Dimensional Nanostructures into Functional Networks
Huang, Y., Duan, X., Wei, Q., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5504.630 · Cited by 2,199
Self-citationEngineering Carbon Nanotubes and Nanotube Circuits Using Electrical Breakdown
Collins, P. G., Arnold, M. S., & Avouris, P. (2001) · Science · doi:10.1126/science.1058782 · Cited by 1,728
Diameter-controlled synthesis of single-crystal silicon nanowires
Cui, Y., Lauhon, L. J., Gudiksen, M. S., Wang, J., & Lieber, C. M. (2001) · Applied Physics Letters · doi:10.1063/1.1363692 · Cited by 1,156
Self-citationDoping and Electrical Transport in Silicon Nanowires
Cui, Y., Duan, X., Hu, J., & Lieber, C. M. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp0009305 · Cited by 950
Self-citationKlee, C. B., & Vanaman, T. C. (1982) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60470-2 · Cited by 778
Light-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
Vezenov, D. V., Noy, A., Rozsnyai, L. F., & Lieber, C. M. (1997) · Journal of the American Chemical Society · doi:10.1021/ja963375m · Cited by 438
Self-citationMovileanu, L., Howorka, S., Braha, O., & Bayley, H. (2000) · Nature Biotechnology · doi:10.1038/80295 · Cited by 366
Monoclonal anti‐biotin antibodies simulate avidin m the recognition of biotin
Bağcı, H., Kohen, F., Kusçuoglu, U., Bayer, E. A., & Wilchek, M. (1993) · FEBS Letters · doi:10.1016/0014-5793(93)81108-c · Cited by 49
Cited by
One‐Dimensional Nanostructures: Synthesis, Characterization, and Applications
Xia, Y., Yang, P., Sun, Y., Wu, Y., Mayers, B., Gates, B., Yin, Y., Kim, F., & Yan, H. (2003) · Advanced Materials · doi:10.1002/adma.200390087 · Cited by 8,559
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Photoinduced Conversion of Silver Nanospheres to Nanoprisms
Jin, R., Cao, Y., Mirkin, C. A., Kelly, K. L., Schatz, G. C., & Zheng, J. G. (2001) · Science · doi:10.1126/science.1066541 · Cited by 3,384
The use of nanocrystals in biological detection
Alivisatos, P. (2004) · Nature Biotechnology · doi:10.1038/nbt927 · Cited by 3,008
Metadata
- Authors
- Cui, Y., Wei, Q., Park, H., & Lieber, C. M.
- Venue
- Science
- Published
- 2001-08-17
- Volume
- 293
- Issue
- 5533
- Pages
- 1289-1292
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1987416224
- Cited by
- 5,809
- References
- 16
- FWCI
- 99.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.