The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Blood Viscosity: Influence of Erythrocyte Deformation
Abstract
Suspensions of canine and human erythocytes hardened with acetaldehyde differ from the suspensions of normal erythrocytes with respect to their rheological behavior. Normal erythrocytes can be packed by centrifugation so that the sediment volume is nearly 100 percent cells, but the hardened erythrocytes (RBC's) can be packed only to approximately 60 percent cells. At the same cell percentage the viscosity of the hardened RBC suspension is higher than that of the suspension of normal erythocytes. An increase in shear stress deforms the normal erythocytes and lowers the suspension viscosity, but has no influence on the viscosity of the hardened cell suspension. In blood with high cell percentages, the shear deformation of normal RBC's plays an important role in reducing viscosity and facilitating flow at high shear stresses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of hematocrit and plasma proteins on human blood rheology at low shear rates.
Chien, S., Usami, S., Taylor, H. M., Lundberg, J. L., & Gregersen, M. I. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.1.81 · Cited by 507
Self-citationBlood Viscosity: Influence of Erythrocyte Aggregation
Chien, S., Usami, S., Dellenback, R. J., Gregersen, M. I., Nanninga, L. B., & Guest, M. M. (1967) · Science · doi:10.1126/science.157.3790.829 · Cited by 289
Self-citationFlow Characteristics of Human Erythrocytes through Polycarbonate Sieves
Gregersen, M. I., Bryant, C. A., Hammerle, W. E., Usami, S., & Chien, S. (1967) · Science · doi:10.1126/science.157.3790.825 · Cited by 185
Self-citation
Cited by
Metabolic dependence of red cell deformability
Weed, R. I., LaCelle, P. L., & Merrill, E. W. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106038 · Cited by 820
Brown, B. G., Bolson, E., Frimer, M., & Dodge, H. T. (1977) · Circulation · doi:10.1161/01.cir.55.2.329 · Cited by 633
A simple method for measuring erythrocyte deformability.
Reid, H. L., Barnes, A. J., Lock, P. J., Dormandy, J. A., & Dormandy, T. L. (1976) · Journal of Clinical Pathology · doi:10.1136/jcp.29.9.855 · Cited by 464
Shear Dependence of Effective Cell Volume as a Determinant of Blood Viscosity
Chien, S. (1970) · Science · doi:10.1126/science.168.3934.977 · Cited by 421
Self-citationPredicting human blood viscosity in silico
Fedosov, D. A., Pan, W., Caswell, B., Gompper, G., & Karniadakis, G. E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1101210108 · Cited by 371
Abnormal rheology of oxygenated blood in sickle cell anemia
Chien, S., Usami, S., & Bertles, J. F. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106273 · Cited by 356
Self-citationBiophysical Behavior of Red Cells in Suspensions
CHIEN, S. (1975) · The Red Blood Cell · doi:10.1016/b978-0-12-677202-9.50019-8 · Cited by 349
Self-citationFluid Drop-Like Transition of Erythrocytes under Shear
Schmid-Schönbein, H., & Wells, R. (1969) · Science · doi:10.1126/science.165.3890.288 · Cited by 319
Blood Viscosity: Influence of Erythrocyte Aggregation
Chien, S., Usami, S., Dellenback, R. J., Gregersen, M. I., Nanninga, L. B., & Guest, M. M. (1967) · Science · doi:10.1126/science.157.3790.829 · Cited by 289
Self-citationA quasi-mechanistic mathematical representation for blood viscosity.
Hund, S., Kameneva, M., & Antaki, J. (2017) · Fluids · doi:10.3390/fluids2010010 · Cited by 65
Metadata
- Authors
- Chien, S., Usami, S., Dellenback, R. J., & Gregersen, M. I.
- Venue
- Science
- Published
- 1967-08-18
- Volume
- 157
- Issue
- 3790
- Pages
- 827-829
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2052734558
- Cited by
- 284
- References
- 3
- FWCI
- 30.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.