The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The Scanning Ion-Conductance Microscope
Abstract
A scanning ion-conductance microscope (SICM) has been developed that can image the topography of nonconducting surfaces that are covered with electrolytes. The probe of the SICM is an electrolyte-filled micropipette. The flow of ions through the opening of the pipette is blocked at short distances between the probe and the surface, thus limiting the ion conductance. A feedback mechanism can be used to maintain a given conductance and in turn determine the distance to the surface. The SICM can also sample and image the local ion currents above the surfaces. To illustrate its potential for imaging ion currents through channels in membranes, a topographic image of a membrane filter with 0.80-micrometer pores and an image of the ion currents flowing through such pores are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Surface Studies by Scanning Tunneling Microscopy
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Physical Review Letters · doi:10.1103/physrevlett.49.57 · Cited by 4,777
Scanning electrochemical microscopy. Introduction and principles
Bard, A. J., Fan, F. R. F., Kwak, J., & Lev, O. (1989) · Analytical Chemistry · doi:10.1021/ac00177a011 · Cited by 1,151
Development of a 500 Å spatial resolution light microscope
Lewis, A., Isaacson, M., Harootunian, A., & Muray, A. (1984) · Ultramicroscopy · doi:10.1016/0304-3991(84)90201-8 · Cited by 757
Williams, C. C., & Wickramasinghe, H. K. (1986) · Applied Physics Letters · doi:10.1063/1.97288 · Cited by 413
Atomic-scale surface modifications using a tunnelling microscope
Becker, R. S., Golovchenko, J. A., & Swartzentruber, B. S. (1987) · Nature · doi:10.1038/325419a0 · Cited by 319
Cited by
Nanopore analytics: sensing of single molecules
Howorka, S., & Siwy, Z. (2009) · Chemical Society Reviews · doi:10.1039/b813796j · Cited by 1,170
Imaging modes of atomic force microscopy for application in molecular and cell biology
Dufrêne, Y. F., Ando, T., Garcia, R., Alsteens, D., Martinez-Martin, D., Engel, A., Gerber, C., & Müller, D. J. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.45 · Cited by 945
Current Rectification at Quartz Nanopipet Electrodes
Wei, C., Bard, A. J., & Feldberg, S. W. (1997) · Analytical Chemistry · doi:10.1021/ac970551g · Cited by 576
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
β 2 -Adrenergic Receptor Redistribution in Heart Failure Changes cAMP Compartmentation
Nikolaev, V. O., Moshkov, A., Lyon, A. R., Miragoli, M., Novak, P., Paur, H., Lohse, M. J., Korchev, Y. E., Harding, S. E., & Gorelik, J. (2010) · Science · doi:10.1126/science.1185988 · Cited by 556
Metadata
- Authors
- Hansma, P. K., Drake, B., Marti, O., Gould, S. A. C., & Prater, C. B.
- Venue
- Science
- Published
- 1989-02-03
- Volume
- 243
- Issue
- 4891
- Pages
- 641-643
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2077813193
- Cited by
- 849
- References
- 6
- FWCI
- 12.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.