The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Abstract
Micromachining technology was used to prepare chemical analysis systems on glass chips (1 centimeter by 2 centimeters or larger) that utilize electroosmotic pumping to drive fluid flow and electrophoretic separation to distinguish sample components. Capillaries 1 to 10 centimeters long etched in the glass (cross section, 10 micrometers by 30 micrometers) allow for capillary electrophoresis-based separations of amino acids with up to 75,000 theoretical plates in about 15 seconds, and separations of about 600 plates can be effected within 4 seconds. Sample treatment steps within a manifold of intersecting capillaries were demonstrated for a simple sample dilution process. Manipulation of the applied voltages controlled the directions of fluid flow within the manifold. The principles demonstrated in this study can be used to develop a miniaturized system for sample handling and separation with no moving parts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Self-citationSilicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Zone electrophoresis in open-tubular glass capillaries
Jorgenson, J. W., & Lukacs, K. D. (1981) · Analytical Chemistry · doi:10.1021/ac00231a037 · Cited by 2,229
A gas chromatographic air analyzer fabricated on a silicon wafer
Terry, S. C., Jerman, J. H., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19791 · Cited by 1,452
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Self-citationManz, A., Harrison, D. J., Verpoorte, E. M. J., Fettinger, J. C., Paulus, A., Lüdi, H., & Widmer, H. M. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80293-4 · Cited by 1,042
Self-citationMicrofabrication Techniques for Integrated Sensors and Microsystems
Wise, K. D., & Najafi, K. (1991) · Science · doi:10.1126/science.1962192 · Cited by 309
Manz, A., Fettinger, J. C., Verpoorte, E., Lüdi, H., Widmer, H. M., & Harrison, D. J. (1991) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(91)85116-9 · Cited by 228
Self-citationOn-column sample gating for high-speed capillary zone electrophoresis
Monnig, C. A., & Jorgenson, J. W. (1991) · Analytical Chemistry · doi:10.1021/ac00008a013 · Cited by 162
Prototype miniature blood gas analyser fabricated on a silicon wafer
Shoji, S., Esashi, M., & Matsuo, T. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)80057-x · Cited by 124
Cited by
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Quantum-dot-tagged microbeads for multiplexed optical coding of biomolecules
Han, M., Gao, X., Su, J. Z., & Nie, S. (2001) · Nature Biotechnology · doi:10.1038/90228 · Cited by 2,631
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Self-citationLaser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Self-citationMicrofluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Submicrometer Metallic Barcodes
Nicewarner-Peña, S. R., Freeman, R. G., Reiss, B. D., He, L., Peña, D. J., Walton, I. D., Cromer, R., Keating, C. D., & Natan, M. J. (2001) · Science · doi:10.1126/science.294.5540.137 · Cited by 1,213
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Separation of enantiomers: needs, challenges, perspectives
Maier, N. M., Franco, P., & Lindner, W. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00532-x · Cited by 1,014
Controlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Surface-Directed Liquid Flow Inside Microchannels
Zhao, B., Moore, J. S., & Beebe, D. J. (2001) · Science · doi:10.1126/science.291.5506.1023 · Cited by 765
SURVEY AND SUMMARY: From DNA biosensors to gene chips
Wang, J. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.16.3011 · Cited by 753
Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Scaling and the design of miniaturized chemical-analysis systems
Janasek, D., Franzke, J., & Manz, A. (2006) · Nature · doi:10.1038/nature05059 · Cited by 716
Self-citationAnderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Jacobson, S. C., Hergenroder, R., Koutny, L. B., Warmack, R. J., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a028 · Cited by 669
Microfluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Self-citationPCR microfluidic devices for DNA amplification
Zhang, C., Xu, J., Ma, W., & Zheng, W. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.10.002 · Cited by 634
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Flexible Methods for Microfluidics
Whitesides, G. M., & Stroock, A. D. (2001) · Physics Today · doi:10.1063/1.1387591 · Cited by 595
Combinatorial and Evolution-Based Methods in the Creation of Enantioselective Catalysts
Reetz, M. T. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010119)40:2<284::aid-anie284>3.0.co;2-n · Cited by 594
Surface modification of poly(dimethylsiloxane) microchannels
Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305627 · Cited by 551
Fabrication of Plastic Microfluid Channels by Imprinting Methods
Martynova, L., Locascio, L. E., Gaitan, M., Kramer, G. W., Christensen, R. G., & MacCrehan, W. A. (1997) · Analytical Chemistry · doi:10.1021/ac970558y · Cited by 533
Ion-Enrichment and Ion-Depletion Effect of Nanochannel Structures
Pu, Q., Yun, J., Temkin, H., & Liu, S. (2004) · Nano Letters · doi:10.1021/nl0494811 · Cited by 532
Wong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Ion Transport in Nanofluidic Channels
Daiguji, H., Yang, P., & Majumdar, A. (2004) · Nano Letters · doi:10.1021/nl0348185 · Cited by 520
Hansen, C. L., Skordalakes, E., Berger, J. M., & Quake, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.262485199 · Cited by 517
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
An Integrated Microfabricated Cell Sorter
Fu, A. Y., Chou, H.-P., Spence, C., Arnold, F. H., & Quake, S. R. (2002) · Analytical Chemistry · doi:10.1021/ac0255330 · Cited by 510
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Microfluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 502
UV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems
Roberts, M. A., Rossier, J. S., Bercier, P., & Girault, H. (1997) · Analytical Chemistry · doi:10.1021/ac961038q · Cited by 497
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Emerging technologies in DNA sequencing
Metzker, M. L. (2005) · Genome Research · doi:10.1101/gr.3770505 · Cited by 491
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Fabrication Methods for Microfluidic Devices: An Overview
Scott, S., & Ali, Z. (2021) · Micromachines · doi:10.3390/mi12030319 · Cited by 479
Micro reactors: principles and applications in organic synthesis
Fletcher, P. D. I., Haswell, S. J., Pombo-Villar, E., Warrington, B. H., Watts, P., Wong, S. Y. F., & Zhang, X. (2002) · Tetrahedron · doi:10.1016/s0040-4020(02)00432-5 · Cited by 468
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
High-Speed Separations on a Microchip
Jacobson, S. C., Hergenroder, R., Koutny, L. B., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a029 · Cited by 450
Green and Sustainable Chemical Synthesis Using Flow Microreactors
Yoshida, J., Kim, H., & Nagaki, A. (2011) · ChemSusChem · doi:10.1002/cssc.201000271 · Cited by 442
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Li, P. C. H., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606564 · Cited by 422
Self-citationAn Integrated Fluorescence Detection System in Poly(dimethylsiloxane) for Microfluidic Applications
Chabinyc, M. L., Chiu, D. T., McDonald, J. C., Stroock, A. D., Christian, J. F., Karger, A. M., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac010423z · Cited by 419
Surface Modification of Poly(dimethylsiloxane) Microfluidic Devices by Ultraviolet Polymer Grafting
Hu, S., Ren, X., Bachman, M., Sims, C. E., Li, G. P., & Allbritton, N. (2002) · Analytical Chemistry · doi:10.1021/ac025700w · Cited by 418
OPTICAL DETECTION OF SINGLE MOLECULES
Nie, S., & Zare, R. N. (1997) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.26.1.567 · Cited by 412
Biomolecular screening with encoded porous-silicon photonic crystals
Cunin, F., Schmedake, T. A., Link, J. R., Li, Y. Y., Koh, J., Bhatia, S. N., & Sailor, M. J. (2002) · Nature Materials · doi:10.1038/nmat702 · Cited by 409
The centrifugal microfluidic Bio-Disk platform
Ducrée, J., Haeberle, S., Lutz, S., Pausch, S., Stetten, F. V., & Zengerle, R. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/7/s07 · Cited by 405
Microchip Device for Cell Lysis, Multiplex PCR Amplification, and Electrophoretic Sizing
Waters, L. C., Jacobson, S. C., Kroutchinina, N., Khandurina, J., Foote, R. S., & Ramsey, J. M. (1998) · Analytical Chemistry · doi:10.1021/ac970642d · Cited by 405
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Chiem, N., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606620 · Cited by 397
Self-citationA practical guide for the fabrication of microfluidic devices using glass and silicon
Iliescu, C., Taylor, H., Avram, M., Miao, J., & Franssila, S. (2012) · Biomicrofluidics · doi:10.1063/1.3689939 · Cited by 385
Microchip Device for Performing Enzyme Assays
Hadd, A. G., Raymond, D. E., Halliwell, J. W., Jacobson, S. C., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac970192p · Cited by 383
Optofluidic control using photothermal nanoparticles
Liu, G. L., Kim, J., Lu, Y., & Lee, L. P. (2006) · Nature Materials · doi:10.1038/nmat1528 · Cited by 364
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Passively Driven Integrated Microfluidic System for Separation of Motile Sperm
Cho, B. S., Schuster, T. G., Zhu, X., Chang, D., Smith, G. D., & Takayama, S. (2003) · Analytical Chemistry · doi:10.1021/ac020579e · Cited by 356
Microchip-Based Purification of DNA from Biological Samples
Breadmore, M. C., Wolfe, K. A., Arcibal, I. G., Leung, W. K., Dickson, D., Giordano, B. C., Power, M. E., Ferrance, J. P., Feldman, S. H., Norris, P. M., et al. (2003) · Analytical Chemistry · doi:10.1021/ac0204855 · Cited by 351
Generating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac9610671 · Cited by 350
Planar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Ion concentrations and velocity profiles in nanochannel electroosmotic flows
Qiao, R., & Aluru, N. R. (2003) · The Journal of Chemical Physics · doi:10.1063/1.1543140 · Cited by 347
Cell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
Microvalves and Micropumps for BioMEMS
Au, A. K., Lai, H., Utela, B. R., & Folch, A. (2011) · Micromachines · doi:10.3390/mi2020179 · Cited by 332
A sensitive, versatile microfluidic assay for bacterial chemotaxis
Mao, H., Cremer, P. S., & Manson, M. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0931258100 · Cited by 332
Femtosecond laser microstructuring: an enabling tool for optofluidic lab‐on‐chips
Osellame, R., Hoekstra, H. J. W. M., Cerullo, G., & Pollnau, M. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.201000031 · Cited by 320
Surface Modification of Poly(methyl methacrylate) Used in the Fabrication of Microanalytical Devices
Henry, A. C., Tutt, T. J., Galloway, M., Davidson, Y. Y., McWhorter, C. S., Soper, S. A., & McCarley, R. L. (2000) · Analytical Chemistry · doi:10.1021/ac000685l · Cited by 319
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels
Berdichevsky, Y., Khandurina, J., Guttman, A., & Lo, Y.-H. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.022 · Cited by 318
High-Speed DNA Genotyping Using Microfabricated Capillary Array Electrophoresis Chips
Woolley, A. T., Sensabaugh, G. F., & Mathies, R. A. (1997) · Analytical Chemistry · doi:10.1021/ac961237+ · Cited by 310
Optical and Interferometric Lithography - Nanotechnology Enablers
Brueck, S. R. J. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.853538 · Cited by 304
Super-Hydrophobicity of Large-Area Honeycomb-Like Aligned Carbon Nanotubes
Li, S., Li, H., Wang, X., Song, Y., Liu, Y., Jiang, L., & Zhu, D. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp0209401 · Cited by 299
Emrich, C. A., Tian, H., Medintz, I. L., & Mathies, R. A. (2002) · Analytical Chemistry · doi:10.1021/ac020236g · Cited by 284
Bousse, L., Mouradian, S., Minalla, A., Yee, H., Williams, K., & Dubrow, R. (2001) · Analytical Chemistry · doi:10.1021/ac0012492 · Cited by 283
Thermocapillary pumping of discrete drops in microfabricated analysis devices
Sammarco, T. S., & Burns, M. A. (1999) · AIChE Journal · doi:10.1002/aic.690450215 · Cited by 282
Diffusion-based extraction in a microfabricated device
Brody, J. P., & Yager, P. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)80219-1 · Cited by 278
Microfluidic Temperature Gradient Focusing
Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac025528w · Cited by 278
Electroosmosis- and Pressure-Driven Chromatography in Chips Using Continuous Beds
Ericson, C., Holm, J., Ericson, T., & Hjertén, S. (2000) · Analytical Chemistry · doi:10.1021/ac990802g · Cited by 278
Optofluidics for energy applications
Erickson, D., Sinton, D., & Psaltis, D. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.209 · Cited by 277
Electroosmotic pumping and electrophoretic separations for miniaturized chemical analysis systems
Manz, A., Effenhauser, C. S., Burggraf, N., Harrison, D. J., Seiler, K., & Fluri, K. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/010 · Cited by 277
Self-citationEvolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Integrated Cell Isolation and Polymerase Chain Reaction Analysis Using Silicon Microfilter Chambers
Wilding, P., Kricka, L. J., Cheng, J., Hvichia, G., Shoffner, M. A., & Fortina, P. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2530 · Cited by 276
Prototyping of Microfluidic Devices in Poly(dimethylsiloxane) Using Solid-Object Printing
McDonald, J. C., Chabinyc, M. L., Metallo, S. J., Anderson, J. R., Stroock, A. D., & Whitesides, G. M. (2002) · Analytical Chemistry · doi:10.1021/ac010938q · Cited by 266
Chiem, N. H., & Harrison, D. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.591 · Cited by 264
Self-citationPaegel, B. M., Emrich, C. A., Wedemayer, G. J., Scherer, J. R., & Mathies, R. A. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012608699 · Cited by 263
Development and evaluation of a microdevice for amino acid biomarker detection and analysis on Mars
Skelley, A. M., Scherer, J. R., Aubrey, A. D., Grover, W. H., Ivester, R. H. C., Ehrenfreund, P., Grunthaner, F. J., Bada, J. L., & Mathies, R. A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406798102 · Cited by 262
Grover, W. H., Ivester, R. H. C., Jensen, E. C., & Mathies, R. A. (2006) · Lab on a Chip · doi:10.1039/b518362f · Cited by 253
Protein separation by capillary gel electrophoresis: A review
Zhu, Z., Lu, J. J., & Liu, S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.10.022 · Cited by 202
Emotion-on-a-chip (EOC): Evolution of biochip technology to measure human emotion using body fluids
Lee, J.-H., Hwang, Y., Cheon, K.-A., & Jung, H.-I. (2012) · Medical Hypotheses · doi:10.1016/j.mehy.2012.09.002 · Cited by 20
Metadata
- Authors
- Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A.
- Venue
- Science
- Published
- 1993-08-13
- Volume
- 261
- Issue
- 5123
- Pages
- 895-897
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1972466773
- Cited by
- 1,800
- References
- 12
- FWCI
- 21.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.