Conformation of Macromolecules in the Gas Phase: Use of Matrix-Assisted Laser Desorption Methods in Ion Chromatography
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Conformational data for macromolecules in the gas phase have been obtained by the coupling of a matrix-assisted laser desorption ion source to an ion chromatograph. A series of polyethylene glycol (PEG) polymers "cationized" (converted to a cation) by sodium ions (Na + PEG9 to Na + PEG19) and a protonated neurotransmitter protein, bradykinin, were studied. Mobilities of Na + PEG9 to Na + PEG19 are reported. Detailed modeling of Na + PEG9 with molecular mechanics methods indicates that the lowest energy structure has the Na + ion "solvated" by the polymer chain with seven oxygen atoms as nearest neighbors. The agreement between the model and experiment is within 1 percent for Na + PEG9, Na + PEG13, and Na + PEG17, giving strong support to both the method and the deduced structures. Similar agreement was obtained in initial studies that modeled experimental data for arginine-protonated bradykinin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Validation of the general purpose tripos 5.2 force field
Clark, M., Cramer, R. D., & Van Opdenbosch, N. (1989) · Journal of Computational Chemistry · doi:10.1002/jcc.540100804 · Cited by 2,812
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
Carbon cluster cations with up to 84 atoms: structures, formation mechanism, and reactivity
von Helden, G., Hsu, M. T., Gotts, N., & Bowers, M. T. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100133a011 · Cited by 593
Self-citationKatta, V., Chait, B. T., & Carr, S. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050415 · Cited by 453
Cinnamic acid derivatives as matrices for ultraviolet laser desorption mass spectrometry of proteins
Beavis, R. C., Chait, B. T., & Fales, H. M. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290031207 · Cited by 416
MASS SPECTROMETRY OF PEPTIDES AND PROTEINS
Biemann, K. (1992) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.61.070192.004553 · Cited by 390
Cited by
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
Polyethylene glycol and solutions of polyethylene glycol as green reaction media
ChenCurrent address: Key Lab. of Ra, J., Spear, S. K., Huddleston, J. G., & Rogers, R. D. (2005) · Green Chemistry · doi:10.1039/b413546f · Cited by 1,027
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
An exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819
Ion formation in MALDI mass spectrometry
Zenobi, R., & Knochenmuss, R. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:5<337::aid-mas2>3.0.co;2-s · Cited by 819
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Maldi time-of-flight mass spectrometry of synthetic polymers
Nielen, M. W. F. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:5<309::aid-mas2>3.0.co;2-l · Cited by 566
The molecular sociology of the cell
Robinson, C. V., Sali, A., & Baumeister, W. (2007) · Nature · doi:10.1038/nature06523 · Cited by 538
Biomolecule Analysis by Ion Mobility Spectrometry
Bohrer, B. C., Merenbloom, S. I., Koeniger, S. L., Hilderbrand, A. E., & Clemmer, D. E. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113001 · Cited by 492
Protein Structure in Vacuo: Gas-Phase Conformations of BPTI and Cytochrome c
Shelimov, K. B., Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9619059 · Cited by 414
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Schnier, P. D., Price, W. D., Jockusch, R. A., & Williams, E. R. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9609157 · Cited by 394
Gas-Phase Conformation of Biological Molecules: Bradykinin
Wyttenbach, T., von Helden, G., & Bowers, M. T. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9535928 · Cited by 384
Self-citationFundamentals of Trapped Ion Mobility Spectrometry
Michelmann, K., Silveira, J. A., Ridgeway, M. E., & Park, M. A. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0999-4 · Cited by 374
Bleiholder, C., Dupuis, N. F., Wyttenbach, T., & Bowers, M. T. (2011) · Nature Chemistry · doi:10.1038/nchem.945 · Cited by 366
Self-citationThree-Dimensional Ion Mobility/TOFMS Analysis of Electrosprayed Biomolecules
Hoaglund, C. S., Valentine, S. J., Sporleder, C. R., Reilly, J. P., & Clemmer, D. E. (1998) · Analytical Chemistry · doi:10.1021/ac980059c · Cited by 345
Amyloid β-Protein: Monomer Structure and Early Aggregation States of Aβ42 and Its Pro19Alloform
Bernstein, S. L., Wyttenbach, T., Baumketner, A., Shea, J.-E., Bitan, G., Teplow, D. B., & Bowers, M. T. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044531p · Cited by 341
Self-citationEffect of the long-range potential on ion mobility measurements
Wyttenbach, T., von Helden, G., Batka, J. J., Carlat, D., & Bowers, M. T. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00236-x · Cited by 332
Self-citationHoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Ion mobility–mass spectrometry: a new paradigm for proteomics
McLean, J. A., Ruotolo, B. T., Gillig, K. J., & Russell, D. H. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.10.003 · Cited by 309
High-resolution ion mobility measurements
Dugourd, P., Hudgins, R. R., Clemmer, D. E., & Jarrold, M. F. (1997) · Review of Scientific Instruments · doi:10.1063/1.1147873 · Cited by 299
Secondary Electrospray Ionization Ion Mobility Spectrometry/Mass Spectrometry of Illicit Drugs
Wu, C., Siems, W. F., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac9907235 · Cited by 278
X-Ray Diffraction from Isolated and Strongly Aligned Gas-Phase Molecules with a Free-Electron Laser
Küpper, J., Stern, S., Holmegaard, L., Filsinger, F., Rouzée, A., Rudenko, A., Johnsson, P., Martin, A. V., Adolph, M., Aquila, A., et al. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.083002 · Cited by 271
Valentine, S. J., Anderson, J. G., Ellington, A. D., & Clemmer, D. E. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp970217o · Cited by 234
Bleiholder, C., Wyttenbach, T., & Bowers, M. T. (2011) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2011.06.014 · Cited by 218
Self-citationProfiling and imaging of tissues by imaging ion mobility‐mass spectrometry
McLean, J. A., Ridenour, W. B., & Caprioli, R. M. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1254 · Cited by 209
Mass Spectrometry of Protein Complexes: From Origins to Applications
Mehmood, S., Allison, T. M., & Robinson, C. V. (2015) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040214-121732 · Cited by 199
Proton Transfer Reactivity of Large Multiply Charged Ions
Williams, E. R. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199608)31:8<831::aid-jms392>3.0.co;2-7 · Cited by 195
H/D Exchange Levels of Shape-Resolved Cytochrome c Conformers in the Gas Phase
Valentine, S. J., & Clemmer, D. E. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9626751 · Cited by 184
Do ionic charges in ESI MS provide useful information on macromolecular structure?
Kaltashov, I. A., & Abzalimov, R. R. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.05.018 · Cited by 170
“Such extreme flexibility may allow more than one functional group to participate in binding a single proton in a fashion similar to that observed in solvation of larger cations by polymer chains in the gas phase [25].”
BackgroundHyung, S.-J., Robinson, C. V., & Ruotolo, B. T. (2009) · Chemistry & Biology · doi:10.1016/j.chembiol.2009.02.008 · Cited by 169
“We also observe the appearance of a minor signal corresponding to 16+ charge state of tetramer due to loss of negatively charged counterions from 15+ charge state of tetramers ( Sobott and Robinson, 2004 ).”
Coupling High-Pressure MALDI with Ion Mobility/Orthogonal Time-of-Flight Mass Spectrometry
Gillig, K. J., Ruotolo, B., Stone, E. G., Russell, D. H., Fuhrer, K., Gonin, M., & Schultz, A. J. (2000) · Analytical Chemistry · doi:10.1021/ac0005619 · Cited by 162
Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?
Campuzano, I. D., & Lippens, J. L. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.008 · Cited by 42
Wang, X., Norgate, E., Dai, J., Benoit, F., Bristow, T., England, R. M., Kalapothakis, J. M. D., & Barran, P. E. (2025) · Nature Communications · doi:10.1038/s41467-025-59065-x · Cited by 7
Metadata
- Authors
- von Helden, G., Wyttenbach, T., & Bowers, M. T.
- Venue
- Science
- Published
- 1995-03-10
- Volume
- 267
- Issue
- 5203
- Pages
- 1483-1485
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2014140929
- Cited by
- 363
- References
- 22
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.