The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Conformation of Macromolecules in the Gas Phase: Use of Matrix-Assisted Laser Desorption Methods in Ion Chromatography
Abstract
Conformational data for macromolecules in the gas phase have been obtained by the coupling of a matrix-assisted laser desorption ion source to an ion chromatograph. A series of polyethylene glycol (PEG) polymers "cationized" (converted to a cation) by sodium ions (Na + PEG9 to Na + PEG19) and a protonated neurotransmitter protein, bradykinin, were studied. Mobilities of Na + PEG9 to Na + PEG19 are reported. Detailed modeling of Na + PEG9 with molecular mechanics methods indicates that the lowest energy structure has the Na + ion "solvated" by the polymer chain with seven oxygen atoms as nearest neighbors. The agreement between the model and experiment is within 1 percent for Na + PEG9, Na + PEG13, and Na + PEG17, giving strong support to both the method and the deduced structures. Similar agreement was obtained in initial studies that modeled experimental data for arginine-protonated bradykinin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Validation of the general purpose tripos 5.2 force field
Clark, M., Cramer, R. D., & Van Opdenbosch, N. (1989) · Journal of Computational Chemistry · doi:10.1002/jcc.540100804 · Cited by 2,812
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
Carbon cluster cations with up to 84 atoms: structures, formation mechanism, and reactivity
von Helden, G., Hsu, M. T., Gotts, N., & Bowers, M. T. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100133a011 · Cited by 593
Self-citationKatta, V., Chait, B. T., & Carr, S. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050415 · Cited by 453
Cinnamic acid derivatives as matrices for ultraviolet laser desorption mass spectrometry of proteins
Beavis, R. C., Chait, B. T., & Fales, H. M. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290031207 · Cited by 416
MASS SPECTROMETRY OF PEPTIDES AND PROTEINS
Biemann, K. (1992) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.61.070192.004553 · Cited by 390
Coexisting stable conformations of gaseous protein ions.
Suckau, D., Shi, Y., Beu, S. C., Senko, M. W., Quinn, J. P., Wampler, F. M., & McLafferty, F. W. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.3.790 · Cited by 345
Chait, B. T., Wang, R., Beavis, R. C., & Kent, S. B. H. (1993) · Science · doi:10.1126/science.8211132 · Cited by 309
Loo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
Gas-Phase Ion Chromatography: Transition Metal State Selection and Carbon Cluster Formation
Bowers, M. T., Kemper, P. R., von Helden, G., & van Koppen, P. A. M. (1993) · Science · doi:10.1126/science.260.5113.1446 · Cited by 289
Self-citationCollision cross sections for protein ions
Covey, T., & Douglas, D. J. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85025-s · Cited by 253
Matrix‐assisted laser‐desorption mass spectrometry using 355 nm radiation
Beavis, R. C., Chait, B. T., & Standing, K. G. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290031208 · Cited by 190
Electronic-state chromatography: application to first-row transition-metal ions
Kemper, P. R., & Bowers, M. T. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100166a042 · Cited by 182
Self-citationWinger, B. E., Light-Wahl, K. J., Rockwood, A. L., & Smith, R. D. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00040a084 · Cited by 177
Richards, F. M. (1991) · Scientific American · doi:10.1038/scientificamerican0191-54 · Cited by 157
Are the electrospray mass spectra of proteins related to their aqueous solution chemistry?
Guevremont, R., Siu, K. W. M., Blanc, J. C. Y. L., & Berman, S. S. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87005-j · Cited by 134
Hu, P., & Gross, M. L. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00049a056 · Cited by 81
von Helden, G., Porter, E., Gotts, N. G., & Bowers, M. T. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100019a059 · Cited by 25
Self-citation
Cited by
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
Polyethylene glycol and solutions of polyethylene glycol as green reaction media
ChenCurrent address: Key Lab. of Ra, J., Spear, S. K., Huddleston, J. G., & Rogers, R. D. (2005) · Green Chemistry · doi:10.1039/b413546f · Cited by 1,027
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
An exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819
Ion formation in MALDI mass spectrometry
Zenobi, R., & Knochenmuss, R. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:5<337::aid-mas2>3.0.co;2-s · Cited by 819
Metadata
- Authors
- von Helden, G., Wyttenbach, T., & Bowers, M. T.
- Venue
- Science
- Published
- 1995-03-10
- Volume
- 267
- Issue
- 5203
- Pages
- 1483-1485
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2014140929
- Cited by
- 363
- References
- 22
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.