The DOI matches its Crossref record.
Direct Measurement of a Tethered Ligand-Receptor Interaction Potential
Abstract
Many biological recognition interactions involve ligands and receptors that are tethered rather than rigidly bound on a cell surface. A surface forces apparatus was used to directly measure the force-distance interaction between a polymer-tethered ligand and its receptor. At separations near the fully extended tether length, the ligands rapidly lock onto their binding sites, pulling the ligand and receptor together. The measured interaction potential and its dynamics can be modeled with standard theories of polymer and colloidal interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multifunctional and stimuli-sensitive pharmaceutical nanocarriers
Torchilin, V. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.09.026 · Cited by 583
Zappone, B., Ruths, M., Greene, G. W., Jay, G. D., & Israelachvili, J. N. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.088799 · Cited by 341
Self-citationBenz, M., Chen, N., & Israelachvili, J. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30123 · Cited by 161
Self-citationTargeted binding of PLA microparticles with lipid-PEG-tethered ligands
Duncanson, W. J., Figa, M. A., Hallock, K., Zalipsky, S., Hamilton, J. A., & Wong, J. Y. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.05.044 · Cited by 75
Self-citation
Metadata
- Authors
- Wong, J. Y., Kuhl, T. L., Israelachvili, J. N., Mullah, N., & Zalipsky, S.
- Venue
- Science
- Published
- 1997-02-07
- Volume
- 275
- Issue
- 5301
- Pages
- 820-822
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2003140922
- Cited by
- 255
- References
- 0
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct Measurement of a Tethered Ligand-Receptor Interaction Potential. https://app.cochat.ai/papers/10.1126/science.275.5301.820
- The paper
- Wong, J. Y., Kuhl, T. L., Israelachvili, J. N., Mullah, N., & Zalipsky, S. (1997). Direct Measurement of a Tethered Ligand-Receptor Interaction Potential. Science. https://doi.org/10.1126/science.275.5301.820
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.