The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Biosensors--Sense and Sensitivity
Abstract
Biosensors are a cunning combination of biological molecules and microelectronics that can be used to measure blood glucose levels, pollutants in the environment or food-borne pathogens in the food supply. In a comprehensive TechView, Anthony Turner takes us on a tour of historical developments and the latest innovations in biosensor research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A biosensor that uses ion-channel switches
Cornell, B. A., Braach-Maksvytis, V. L. B., King, L. G., Osman, P. D. J., Raguse, B., Wieczorek, L., & Pace, R. J. (1997) · Nature · doi:10.1038/42432 · Cited by 1,117
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
Protein Interaction Methods-Toward an Endgame
Mendelsohn, A. R., & Brent, R. (1999) · Science · doi:10.1126/science.284.5422.1948 · Cited by 136
Development of a green fluorescent protein reporter for a yeast genotoxicity biosensor
Billinton, N., Barker, M. G., Michel, C., Knight, A. W., Heyer, W., Goddard, N. J., Fielden, P. R., & Walmsley, R. M. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00049-9 · Cited by 76
Tombelli, S., Mascini, M., Braccini, L., Anichini, M., & Turner, A. P. F. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00092-0 · Cited by 67
Self-citationExploiting antibody-based technologies to manage environmental pollution
Harris, B. (1999) · Trends in biotechnology · doi:10.1016/s0167-7799(99)01308-6 · Cited by 67
Design of a Biosensor for Continual, Transdermal Glucose Monitoring
Tierney, M. J., Jayalakshmi, Y., Parris, N. A., Reidy, M. P., Uhegbu, C. E., & Vijayakumar, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1681 · Cited by 59
Cited by
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Detection and localization of single molecular recognition events using atomic force microscopy
Hinterdorfer, P., & Dufrêne, Y. F. (2006) · Nature Methods · doi:10.1038/nmeth871 · Cited by 1,055
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Protein detection by optical shift of a resonant microcavity
Vollmer, F., Braun, D., Libchaber, A., Khoshsima, M., Teraoka, I., & Arnold, S. (2002) · Applied Physics Letters · doi:10.1063/1.1482797 · Cited by 903
Recent Advances in Biosensor Technology for Potential Applications – An Overview
Vigneshvar, S., Sudhakumari, C. C., Senthilkumaran, B., & Prakash, H. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00011 · Cited by 674
“The first biosensor invented by Clark and Lyons (1962) to measure glucose in biological samples utilized the strategy of electrochemical detection of oxygen or hydrogen peroxide (Fracchiolla et al., 2013; Turner, 2013) using immobilized glucose oxidase electrode.”
BackgroundMethodInfluential
Metadata
- Authors
- Turner, A. P. F.
- Venue
- Science
- Published
- 2000-11-17
- Volume
- 290
- Issue
- 5495
- Pages
- 1315-1317
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1480588916
- Cited by
- 524
- References
- 7
- FWCI
- 12.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.