From Micro- to Nanofabrication with Soft Materials
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Soft materials are finding applications in areas ranging from microfluidic device technology to nanofabrication. We review recent work in these areas, discuss the motivation for device fabrication with soft materials, and describe applications of soft materials. In particular, we discuss active microfluidic devices for cell sorting and biochemical assays, replication-molded optics with subdiffraction limit features, and nanometer-scale resonators and wires formed from single-molecule DNA templates as examples of how the special properties of soft materials address outstanding problems in device fabrication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Self-citationSilicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
DNA-templated assembly and electrode attachment of a conducting silver wire
Braun, E., Eichen, Y., Sivan, U., & Ben-Yoseph, G. (1998) · Nature · doi:10.1038/35826 · Cited by 2,367
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Self-citationAlignment and Sensitive Detection of DNA by a Moving Interface
Bensimon, A., Simon, A., Chiffaudel, A., Croquette, V., Heslot, F., & Bensimon, D. (1994) · Science · doi:10.1126/science.7522347 · Cited by 843
Anderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Complex Optical Surfaces Formed by Replica Molding Against Elastomeric Masters
Xia, Y., Kim, E., Zhao, X.-M., Rogers, J. A., Prentiss, M., & Whitesides, G. M. (1996) · Science · doi:10.1126/science.273.5273.347 · Cited by 643
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Mirrorless Lasing from Mesostructured Waveguides Patterned by Soft Lithography
Yang, P., Wirnsberger, †. G., Huang, H. C., Cordero, S. R., McGehee, M. D., Scott, B., Deng, T., Whitesides, G. M., Chmelka, B. F., Buratto, S. K., et al. (2000) · Science · doi:10.1126/science.287.5452.465 · Cited by 478
A microfabricated device for sizing and sorting DNA molecules
Chou, H.-P., Spence, C., Scherer, A., & Quake, S. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.1.11 · Cited by 274
Self-citationDesign and Fabrication of Topologically Complex, Three-Dimensional Microstructures
Jackman, R. J., Brittain, S. T., Adams, A., Prentiss, M. G., & Whitesides, G. M. (1998) · Science · doi:10.1126/science.280.5372.2089 · Cited by 168
Li, M., Wang, J., Zhuang, L., & Chou, S. Y. (2000) · Applied Physics Letters · doi:10.1063/1.125896 · Cited by 137
Metallic nanowires created by biopolymer masking
Fritzsche, W., Böhm, K. J., Unger, E., & Köhler, J. M. (1999) · Applied Physics Letters · doi:10.1063/1.125172 · Cited by 56
Diffractive lens fabricated with binary features less than 60 nm
Mait, J. N., Scherer, A., Dial, O., Prather, D. W., & Gao, X. (2000) · Optics Letters · doi:10.1364/ol.25.000381 · Cited by 46
Self-citation
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Self-citationEngineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Eggers, J., & Villermaux, E. (2008) · Reports on Progress in Physics · doi:10.1088/0034-4885/71/3/036601 · Cited by 1,827
Metadata
- Authors
- Quake, S. R., & Scherer, A.
- Venue
- Science
- Published
- 2000-11-24
- Volume
- 290
- Issue
- 5496
- Pages
- 1536-1540
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2104311964
- Cited by
- 1,131
- References
- 18
- FWCI
- 35.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.