The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
A transient, closed-loop network of wireless, body-integrated devices for autonomous electrotherapy
Open accessAbstract
Temporary postoperative cardiac pacing requires devices with percutaneous leads and external wired power and control systems. This hardware introduces risks for infection, limitations on patient mobility, and requirements for surgical extraction procedures. Bioresorbable pacemakers mitigate some of these disadvantages, but they demand pairing with external, wired systems and secondary mechanisms for control. We present a transient closed-loop system that combines a time-synchronized, wireless network of skin-integrated devices with an advanced bioresorbable pacemaker to control cardiac rhythms, track cardiopulmonary status, provide multihaptic feedback, and enable transient operation with minimal patient burden. The result provides a range of autonomous, rate-adaptive cardiac pacing capabilities, as demonstrated in rat, canine, and human heart studies. This work establishes an engineering framework for closed-loop temporary electrotherapy using wirelessly linked, body-integrated bioelectronic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Self-citationSkin-integrated wireless haptic interfaces for virtual and augmented reality
Yu, X., Xie, Z., Yu, Y., Lee, J., Vazquez-Guardado, A., Luan, H., Ruban, J., Ning, X., Akhtar, A., Li, D., et al. (2019) · Nature · doi:10.1038/s41586-019-1687-0 · Cited by 1,025
Self-citationBioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Self-citationBinodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Self-citationAtrial Fibrillation after Cardiac Surgery
Maisel, W. H., Rawn, J. D., & Stevenson, W. G. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-12-200112180-00010 · Cited by 797
A wireless closed-loop system for optogenetic peripheral neuromodulation
Mickle, A. D., Won, S. M., Noh, K. N., Yoon, J., Meacham, K. W., Xue, Y., McIlvried, L. A., Copits, B. A., Samineni, V. K., Crawford, K. E., et al. (2019) · Nature · doi:10.1038/s41586-018-0823-6 · Cited by 514
Self-citationChung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482
Self-citationContinuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Fully implantable and bioresorbable cardiac pacemakers without leads or batteries
Choi, Y. S., Yin, R. T., Pfenniger, A., Koo, J., Avila, R., Benjamin Lee, K., Chen, S. W., Lee, G., Li, G., Qiao, Y., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00948-x · Cited by 361
Self-citationHwang, S.-W., Lee, C. H., Cheng, H., Jeong, J.-W., Kang, S.-K., Kim, J.-H., Shin, J., Yang, J., Liu, Z., Ameer, G. A., et al. (2015) · Nano Letters · doi:10.1021/nl503997m · Cited by 344
Self-citationChoi, Y. S., Hsueh, Y.-Y., Koo, J., Yang, Q., Avila, R., Hu, B., Xie, Z., Lee, G., Ning, Z., Liu, C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19660-6 · Cited by 292
Self-citationYang, Q., Wei, T., Yin, R. T., Wu, M., Xu, Y., Koo, J., Choi, Y. S., Xie, Z., Chen, S. W., Kandela, I., et al. (2021) · Nature Materials · doi:10.1038/s41563-021-01051-x · Cited by 243
Self-citationKrittanawong, C., Rogers, A. J., Johnson, K. W., Wang, Z., Turakhia, M. P., Halperin, J. L., & Narayan, S. M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00445-9 · Cited by 234
External noninvasive temporary cardiac pacing: clinical trials.
Zoll, P. M., Zoll, R. H., Falk, R. H., Clinton, J. E., Eitel, D. R., & Antman, E. M. (1985) · Circulation · doi:10.1161/01.cir.71.5.937 · Cited by 202
Koo, J., Kim, S. B., Choi, Y. S., Xie, Z., Bandodkar, A. J., Khalifeh, J., Yan, Y., Kim, H., Pezhouh, M. K., Doty, K., et al. (2020) · Science Advances · doi:10.1126/sciadv.abb1093 · Cited by 160
Self-citationThe Electrode‐Tissue Interface: The Revolutionary Role of Steroid Elution
Mond, H. G., & STOKES, K. B. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02905.x · Cited by 152
Analysis of pacemaker malfunction and complications of temporary pacing in the coronary care unit
Austin, J. L., Preis, L. K., Crampton, R. S., et al. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90505-7 · Cited by 151
Force, T. L., Hibberd, P. L., Weeks, G., Kemper, A. J., Bloomfield, P. M., Tow, D. E., Josa, M., Khuri, S. F., & Parisi, A. F. (1990) · Circulation · doi:10.1161/01.cir.82.3.903 · Cited by 150
Biodegradable Polyanhydrides as Encapsulation Layers for Transient Electronics
Choi, Y. S., Koo, J., Lee, Y. J., Lee, G., Avila, R. O., Ying, H., Reeder, J. T., Hambitzer, L., Im, K., Jungwon, K., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000941 · Cited by 122
Self-citationJeong, H., Lee, J. Y., Lee, K., Kang, Y. J., Kim, J.-T., Avila, R., Tzavelis, A., Kim, J., Ryu, H., Kwak, S. S., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg3092 · Cited by 121
Self-citationBRAUN, M. U., Rauwolf, T., BOCK, M., Kappert, U., Boscheri, A., Schnabel, A., & Strasser, R. H. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00454.x · Cited by 105
A wireless, skin-interfaced biosensor for cerebral hemodynamic monitoring in pediatric care
Rwei, A. Y., Lu, W., Wu, C., Human, K. A., Suen, E., Franklin, D., Fabiani, M., Gratton, G., Xie, Z., Deng, Y., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2019786117 · Cited by 99
Self-citationInorganic materials for transient electronics in biomedical applications
Choi, Y. S., Koo, J., & Rogers, J. A. (2020) · MRS Bulletin · doi:10.1557/mrs.2020.25 · Cited by 91
Self-citationLee, G., Choi, Y. S., Yoon, H., & Rogers, J. A. (2020) · Matter · doi:10.1016/j.matt.2020.08.021 · Cited by 87
Self-citationBiodegradable and stretchable polymeric materials for transient electronic devices
Liu, K., Tran, H., Feig, V. R., & Bao, Z. (2020) · MRS Bulletin · doi:10.1557/mrs.2020.24 · Cited by 66
Palmisano, P., Zaccaria, M., Luzzi, G., Nacci, F., Anaclerio, M., & Favale, S. (2012) · EP Europace · doi:10.1093/europace/eur419 · Cited by 65
Cardiac pacing in infants and children
McLEOD, K. A. (2010) · Heart · doi:10.1136/hrt.2009.173328 · Cited by 60
Guo, H., D’Andrea, D., Zhao, J., Xu, Y., Zheng, Q., Janes, L. E., Murthy, N. K., Li, R., Xie, Z., Song, Z. F., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202102724 · Cited by 60
Self-citationExtending the limits of wireless power transfer to miniaturized implantable electronic devices
Dinis, H., Colmiais, I., & Mendes, P. (2017) · Micromachines · doi:10.3390/mi8120359 · Cited by 59
The electrode-tissue interface: the revolutionary role of steroid-elution
MOND, H. G., HELLAND, J. R., STOKES, K., BORNZIN, G. A., & McVENES, R. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12461 · Cited by 58
Closed loop stimulation and accelerometer-based rate adaptation: results of the PROVIDE study
Coenen, M., MALINOWSKI, K., Spitzer, W., Schuchert, A., Schmitz, D., Anelli-Monti, M., Maier, S. K. G., Estlinbaum, W., Bauer, A., Muehling, H., et al. (2008) · EP Europace · doi:10.1093/europace/eun024 · Cited by 46
Sensors for rate responsive pacing.
Dell'Orto, S., Valli, P., & Greco, E. M. (2004) · PubMed · Cited by 43
Proietti, R., Manzoni, G. M., Biase, L. D., et al. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03445.x · Cited by 42
Kaszala, K., & Ellenbogen, K. A. (2010) · Circulation · doi:10.1161/circulationaha.109.919704 · Cited by 42
DEVELOPMENTS IN SENSOR-DRIVEN PACING
LEUNG, S., & Lau, C. (2000) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70131-4 · Cited by 30
Espe, E. K. S., Aronsen, J. M., Skårdal, K., Schneider, J. E., Zhang, L., & Sjaastad, I. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-82 · Cited by 29
Nanopatterned Nafion Microelectrode Arrays for In Vitro Cardiac Electrophysiology
Choi, J. S., Smith, A. S. T., Williams, N. P., Matsubara, T., Choi, M., Joon-wan, K. I. M., Kim, H. J., Choi, S., & Kim, D. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910660 · Cited by 25
Self-citationWinter, K.-F., Hartmann, R., & Klinke, R. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)00160-x · Cited by 22
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationSkin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Yang, Y., Guo, X., Zhu, M., Sun, Z., Zhang, Z., He, T., & Lee, C. (2023) · Advanced Energy Materials · doi:10.1002/aenm.202203040 · Cited by 337
Self-citationSelf-Powered Sensing in Wearable Electronics─A Paradigm Shift Technology
Tang, W., Sun, Q., & Wang, Z. L. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00305 · Cited by 300
Green Flexible Electronics: Natural Materials, Fabrication, and Applications
Hui, Z., Zhang, L., Ren, G., Sun, G., Yu, H., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211202 · Cited by 287
Metadata
- Authors
- Choi, Y. S., Jeong, H., Yin, R. T., Avila, R., Pfenniger, A., Yoo, J., Lee, J. Y., Tzavelis, A., Lee, Y. J., Chen, S. W., Knight, H. S., Kim, S., Ahn, H.-Y., Wickerson, G., Vázquez-Guardado, A., Higbee-Dempsey, E., Russo, B. A., Napolitano, M. A., Holleran, T. J., Razzak, L. A., Miniovich, A. N., Lee, G., Geist, B., Kim, B., Han, S., Brennan, J. A., Aras, K., Kwak, S. S., Kim, J., Waters, E. A., Yang, X., Burrell, A., San Chun, K., Liu, C., Wu, C., Rwei, A. Y., Spann, A. N., Banks, A., Johnson, D., Zhang, Z. J., Haney, C. R., Jin, S. H., Sahakian, A. V., Huang, Y., Trachiotis, G. D., Knight, B. P., Arora, R. K., Efimov, I. R., & Rogers, J. A.
- Venue
- Science
- Published
- 2022-05-27
- Volume
- 376
- Issue
- 6596
- Pages
- 1006-1012
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W4281553981
- Cited by
- 267
- References
- 40
- FWCI
- 14.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.