Acid-humidified CO 2 gas input for stable electrochemical CO 2 reduction reaction
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
(Bi)carbonate salt formation has been widely recognized as a primary factor in poor operational stability of the electrochemical carbon dioxide reduction reaction (CO 2 RR). We demonstrate that flowing CO 2 gas into an acid bubbler—which carries trace amounts of acid vapor into a gas diffusion electrode for silver-catalyzed CO 2 RR to carbon monoxide (CO)—can prevent salt accumulation. In a 100-square-centimeter, scaled-up CO 2 RR membrane electrode assembly electrolyzer with single serpentine flow channels, the acid humidification method achieved the 4500 hours of stability milestone at 100 mA cm −2 without compromising the CO faradaic efficiency, whereas a conventional water-humidified CO 2 feed only operated stably for ~80 hours. The acid-humidified CO 2 approach was extended to bismuth, copper, and zinc catalysts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CO 2 electrolysis to multicarbon products at activities greater than 1 A cm −2
García de Arquer, F. P., Dinh, C.-T., Ozden, A., Wicks, J., McCallum, C., Kirmani, A. R., Nam, D.-H., Gabardo, C., Seifitokaldani, A., Wang, X., et al. (2020) · Science · doi:10.1126/science.aay4217 · Cited by 1,517
Domino electroreduction of CO2 to methanol on a molecular catalyst
Wu, Y., Jiang, Z., Lu, X., Liang, Y., & Wang, H. (2019) · Nature · doi:10.1038/s41586-019-1760-8 · Cited by 1,194
Promoter Effects of Alkali Metal Cations on the Electrochemical Reduction of Carbon Dioxide
Resasco, J., Chen, L. D., Clark, E., Tsai, C., Hahn, C., Jaramillo, T. F., Chan, K., & Bell, A. T. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b06765 · Cited by 1,184 · cited 1×
“The presence of salt in the CO 2 RR MEA electrolyzer arises primarily from the utilization of anolytes ( 18 , 19 ), which typically consist of alkali metal cations such as Na + , K + , and Cs + .”
Gu, J., Liu, S., Ni, W., Ren, W., Haussener, S., & Hu, X. (2022) · Nature Catalysis · doi:10.1038/s41929-022-00761-y · Cited by 846
Operando studies reveal active Cu nanograins for CO2 electroreduction
Yang, Y., Louisia, S., Yu, S., Jin, J., Roh, I., Chen, C., Fonseca Guzman, M. V., Feijóo, J., Chen, P.-C., Wang, H., et al. (2023) · Nature · doi:10.1038/s41586-022-05540-0 · Cited by 830
Self-citationLa- and Mn-doped cobalt spinel oxygen evolution catalyst for proton exchange membrane electrolysis
Chong, L., Gao, G., Wen, J., Li, H., Xu, H., Green, Z., Sugar, J. D., Kropf, A. J., Xu, W., Lin, X.-M., et al. (2023) · Science · doi:10.1126/science.ade1499 · Cited by 823 · cited 1×
“These small cell voltage variations across independent tests were often observed in two-electrode system measurements in CO 2 RR electrolyzers or other electrocatalytic reactions ( 38 , 40 – 43 ), which could arise from small variations in different batches of anodes (figs.”
Techno-economic assessment of low-temperature carbon dioxide electrolysis
Shin, H., Hansen, K. U., & Jiao, F. (2021) · Nature Sustainability · doi:10.1038/s41893-021-00739-x · Cited by 741
Durability challenges of anion exchange membrane fuel cells
Mustain, W. E., Chatenet, M., Page, M., & Kim, Y. S. (2020) · Energy & Environmental Science · doi:10.1039/d0ee01133a · Cited by 677 · cited 1×
“Key issues include catalyst instability ( 9 , 10 ), GDE flooding ( 11 , 12 ), membrane degradation ( 13 , 14 ), and salt formation ( 12 , 15 ).”
The future of low-temperature carbon dioxide electrolysis depends on solving one basic problem
Rabinowitz, J. A., & Kanan, M. W. (2020) · Nature Communications · doi:10.1038/s41467-020-19135-8 · Cited by 658
Technical photosynthesis involving CO2 electrolysis and fermentation
Haas, T., Krause, R., Weber, R., Demler, M., & Schmid, G. (2018) · Nature Catalysis · doi:10.1038/s41929-017-0005-1 · Cited by 649
Gas diffusion electrodes, reactor designs and key metrics of low-temperature CO2 electrolysers
Wakerley, D., Lamaison, S., Wicks, J., Clemens, A., Feaster, J., Corral, D., Jaffer, S. A., Sarkar, A., Fontecave, M., Duoss, E. B., et al. (2022) · Nature Energy · doi:10.1038/s41560-021-00973-9 · Cited by 627
Cu-Ag Tandem Catalysts for High-Rate CO2 Electrolysis toward Multicarbons
Chen, C., Li, Y., Yu, S., Louisia, S., Jin, J., Li, M., Ross, M. B., & Yang, P. (2020) · Joule · doi:10.1016/j.joule.2020.07.009 · Cited by 502
Arges, C. G., & Ramani, V. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1217215110 · Cited by 494 · cited 1×
“Key issues include catalyst instability ( 9 , 10 ), GDE flooding ( 11 , 12 ), membrane degradation ( 13 , 14 ), and salt formation ( 12 , 15 ).”
Yang, K., Kas, R., Smith, W. A., & Burdyny, T. (2021) · ACS Energy Letters · doi:10.1021/acsenergylett.0c02184 · Cited by 474
Durable CO2 conversion in the proton-exchange membrane system
Fang, W., Guo, W., Lu, R., Yan, Y., Liu, X., Wu, D., Li, F. M., Zhou, Y., He, C., Xia, C., et al. (2024) · Nature · doi:10.1038/s41586-023-06917-5 · Cited by 450
Monteiro, M. C. O., Dattila, F., López, N., & Koper, M. T. M. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.1c10171 · Cited by 410
Self-Cleaning CO2 Reduction Systems: Unsteady Electrochemical Forcing Enables Stability
Xu, Y., Edwards, J. P., Liu, S., Miao, R. K., Huang, J. E., Gabardo, C. M., O’Brien, C. P., Li, J., Sargent, E. H., & Sinton, D. (2021) · ACS Energy Letters · doi:10.1021/acsenergylett.0c02401 · Cited by 391
Endrődi, B., Samu, A., Kecsenovity, E., Halmágyi, T., Sebők, D., & Janáky, C. (2021) · Nature Energy · doi:10.1038/s41560-021-00813-w · Cited by 361
Carbon-efficient carbon dioxide electrolysers
Ozden, A., García de Arquer, F. P., Huang, J. E., Wicks, J., Sisler, J., Miao, R. K., O’Brien, C. P., Lee, G., Wang, X., Ip, A. H., et al. (2022) · Nature Sustainability · doi:10.1038/s41893-022-00879-8 · Cited by 324 · cited 1×
“Among various CO 2 electrolyzer designs, the zero-gap membrane electrode assembly (MEA) electrolyzer architecture stands out for its ability to achieve high-efficiency CO 2 reduction reaction (CO 2 RR) at commercially relevant current densities ( 3 , 4 ).”
Cationic-group-functionalized electrocatalysts enable stable acidic CO2 electrolysis
Fan, M., Huang, J. E., Miao, R. K., Mao, Y., Ou, P., Li, F., Li, X.-Y., Cao, Y., Zhang, Z., Zhang, J., et al. (2023) · Nature Catalysis · doi:10.1038/s41929-023-01003-5 · Cited by 315
Lu, X., Zhu, C., Wu, Z., Xuan, J., Francisco, J. S., & Wang, H. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c06779 · Cited by 314
Self-citationEfficient multicarbon formation in acidic CO2 reduction via tandem electrocatalysis
Chen, Y., Li, X.-Y., Chen, Z., Ozden, A., Huang, J. E., Ou, P., Dong, J., Zhang, J., Tian, C., Lee, B.-H., et al. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01543-8 · Cited by 314
Sassenburg, M., Kelly, M., Subramanian, S., Smith, W. A., & Burdyny, T. (2023) · ACS Energy Letters · doi:10.1021/acsenergylett.2c01885 · Cited by 306
Endrődi, B., Kecsenovity, E., Samu, A., Halmágyi, T., Rojas-Carbonell, S., Wang, L., Yan, Y., & Janáky, C. (2020) · Energy & Environmental Science · doi:10.1039/d0ee02589e · Cited by 303
CO2Electrolysis to CO and O2at High Selectivity, Stability and Efficiency Using Sustainion Membranes
Liu, Z., Yang, H., Kutz, R., & Masel, R. I. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0501815jes · Cited by 295
Zhao, Y., Zhang, X.-G., Bodappa, N., Yang, W.-M., Liang, Q., Radjenovica, P. M., Wang, Y.-H., Zhang, Y.-J., Dong, J.-C., Tian, Z.-Q., et al. (2022) · Energy & Environmental Science · doi:10.1039/d2ee01334g · Cited by 293
Li, W., Yin, Z., Gao, Z., Wang, G., Li, Z., Wei, F., Wei, X., Peng, H., Hu, X., Xiao, L., et al. (2022) · Nature Energy · doi:10.1038/s41560-022-01092-9 · Cited by 292
Recovering carbon losses in CO2 electrolysis using a solid electrolyte reactor
Kim, J. Y. ‘., Zhu, P., Chen, F.-Y., Wu, Z.-Y., Cullen, D. A., & Wang, H. (2022) · Nature Catalysis · doi:10.1038/s41929-022-00763-w · Cited by 282
Self-citationCarbon Dioxide and Water Electrolysis Using New Alkaline Stable Anion Membranes
Kaczur, J. J., Yang, H., Liu, Z., Sajjad, S. D., & Masel, R. I. (2018) · Frontiers in Chemistry · doi:10.3389/fchem.2018.00263 · Cited by 275
The Donnan Membrane Principle: Opportunities for Sustainable Engineered Processes and Materials
Sarkar, S., SenGupta, A. K., & Prakash, P. (2010) · Environmental Science & Technology · doi:10.1021/es9024029 · Cited by 270 · cited 1×
“Driven by the electric field, alkali metal cations such as K + can still migrate from the anolyte across the AEM to the cathode catalysts/AEM interface ( 17 ), despite the Donnan exclusion effect of the AEM ( 21 , 22 ).”
Coverage-driven selectivity switch from ethylene to acetate in high-rate CO2/CO electrolysis
Wei, P., Gao, D., Liu, T., Li, H., Sang, J., Wang, C., Cai, R., Wang, G., & Bao, X. (2023) · Nature Nanotechnology · doi:10.1038/s41565-022-01286-y · Cited by 264
Pure-water-fed, electrocatalytic CO2 reduction to ethylene beyond 1,000 h stability at 10 A
She, X., Zhai, L., Wang, Y., Xiong, P., Li, M. M.-J., Wu, T.-S., Wong, M. C., Guo, X., Xu, Z., Li, H., et al. (2024) · Nature Energy · doi:10.1038/s41560-023-01415-4 · Cited by 259
Vos, J. G., Liu, Z., Speck, F. D., Perini, N., Fu, W., Cherevko, S., & Koper, M. T. M. (2019) · ACS Catalysis · doi:10.1021/acscatal.9b01159 · Cited by 245
Pan, B., Fan, J., Zhang, J., Luo, Y., Shen, C., Wang, C., Wang, Y., & Li, Y. (2022) · ACS Energy Letters · doi:10.1021/acsenergylett.2c02292 · Cited by 236
Yan, Z., Hitt, J. L., Zeng, Z., Hickner, M. A., & Mallouk, T. E. (2021) · Nature Chemistry · doi:10.1038/s41557-020-00602-0 · Cited by 225
Reyes, A., Jansonius, R. P., Mowbray, B. A. W., Cao, Y., Wheeler, D. G., Chau, J., Dvorak, D. J., & Berlinguette, C. P. (2020) · ACS Energy Letters · doi:10.1021/acsenergylett.0c00637 · Cited by 209
Potential Dependence of the Local pH in a CO2 Reduction Electrolyzer
Henckel, D. A., Counihan, M. J., Holmes, H. E., Chen, X., Nwabara, U. O., Verma, S., Rodríguez-López, J., Kenis, P. J. A., & Gewirth, A. A. (2021) · ACS Catalysis · doi:10.1021/acscatal.0c04297 · Cited by 204
Moss, A. B., Garg, S., Mirolo, M., Giron Rodriguez, C. A., Ilvonen, R., Chorkendorff, I., Drnec, J., & Seger, B. (2023) · Joule · doi:10.1016/j.joule.2023.01.013 · Cited by 201
Noh, S., Jeon, J. Y., Adhikari, S., Kim, Y. S., & Bae, C. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00355 · Cited by 199 · cited 1×
“This design integrates a gas diffusion electrode (GDE) for efficient mass transport ( 5 , 6 ) and an anion exchange membrane (AEM) to promote ions crossover, optimizing reaction efficiency ( 7 , 8 ).”
Zhu, P., Xia, C., Liu, C.-Y., Jiang, K., Gao, G., Zhang, X., Xia, Y., Lei, Y., Alshareef, H. N., Senftle, T. P., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2010868118 · Cited by 191 · cited 1×
“Cu 2 O was synthesized following the procedure established in our previous work ( 45 , 46 ).”
Self-citationQin, H.-G., Du, Y.-F., Bai, Y.-Y., Li, F.-Z., Yue, X., Wang, H., Peng, J.-Z., & Gu, J. (2023) · Nature Communications · doi:10.1038/s41467-023-41396-2 · Cited by 189
Self-citationDisch, J., Bohn, L., Koch, S., Schulz, M., Han, Y., Tengattini, A., Helfen, L., Breitwieser, M., & Vierrath, S. (2022) · Nature Communications · doi:10.1038/s41467-022-33694-y · Cited by 184
Tran, T. T. V., Kumar, S. R., & Lue, S. J. (2019) · Journal of Membrane Science · doi:10.1016/j.memsci.2018.12.070 · Cited by 183 · cited 1×
“Driven by the electric field, alkali metal cations such as K + can still migrate from the anolyte across the AEM to the cathode catalysts/AEM interface ( 17 ), despite the Donnan exclusion effect of the AEM ( 21 , 22 ).”
Moradzaman, M., & Mul, G. (2021) · ChemElectroChem · doi:10.1002/celc.202001598 · Cited by 179
Unintended cation crossover influences CO2 reduction selectivity in Cu-based zero-gap electrolysers
El‐Nagar, G. A., Haun, F., Gupta, S., Stojkovikj, S., & Mayer, M. T. (2023) · Nature Communications · doi:10.1038/s41467-023-37520-x · Cited by 171
Wu, Y., Charlesworth, L., Maglaya, I., Idros, M. N., Li, M., Burdyny, T., Wang, G., & Rufford, T. E. (2022) · ACS Energy Letters · doi:10.1021/acsenergylett.2c01555 · Cited by 152
Rudolph, W. W., Fischer, D., & Irmer, G. (2006) · Applied Spectroscopy · doi:10.1366/000370206776023421 · Cited by 140
Hybrid oxide coatings generate stable Cu catalysts for CO2 electroreduction
Albertini, P. P., Newton, M. A., Wang, M., Lecina, O. S., Green, P. B., Stoian, D. C., Oveisi, E., Loiudice, A., & Buonsanti, R. (2024) · Nature Materials · doi:10.1038/s41563-024-01819-x · Cited by 138
Xie, K., Ozden, A., Miao, R. K., Li, Y., Sinton, D. A., & Sargent, E. H. (2022) · Nature Communications · doi:10.1038/s41467-022-30677-x · Cited by 129
Visualization of CO2 electrolysis using optical coherence tomography
Lu, X., Zhou, C., Delima, R. S., Lees, E. W., Soni, A., Dvořák, D., Ren, S., Ji, T., Bahi, A., Ko, F., et al. (2024) · Nature Chemistry · doi:10.1038/s41557-024-01465-5 · Cited by 76
Upgrading carbon monoxide to bioplastics via integrated electrochemical reduction and biosynthesis
Wi, T., Xie, Y., Levell, Z. H., Feng, D., Kim, J. Y., Zhu, P., Elgazzar, A., Jeon, T. H., Shakouri, M., Hao, S., et al. (2024) · Nature Synthesis · doi:10.1038/s44160-024-00621-6 · Cited by 58 · cited 1×
“Cu 2 O was synthesized following the procedure established in our previous work ( 45 , 46 ).”
Self-citationScaling CO2 Electrolyzer Cell Area from Bench to Pilot
Nelson, V. E., O’Brien, C. P., Edwards, J. P., Liu, S., Gabardo, C. M., Sargent, E. H., & Sinton, D. A. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c11103 · Cited by 48
Scaling the Electrochemical Conversion of CO2 to CO
Han, K., Rowley, B. C., Schellekens, M. P., Brugman, S. J. T., de Heer, M. P., Keyzer, L., & Corbett, P. J. (2024) · ACS Energy Letters · doi:10.1021/acsenergylett.4c00936 · Cited by 22
Mikami, N., Morishita, K., Murakami, T., Hosobata, T., Yamagata, Y., Ogawa, T., Mukouyama, Y., Nakanishi, S., Ager, J. W., Fujii, K., et al. (2024) · ACS Energy Letters · doi:10.1021/acsenergylett.4c01256 · Cited by 19
Metadata
- Authors
- Hao, S., Elgazzar, A., Zhang, S.-K., Wi, T.-U., Chen, F.-Y., Feng, Y., Zhu, P., & Wang, H.
- Venue
- Science
- Published
- 2025-06-12
- Volume
- 388
- Issue
- 6752
- Pages
- eadr3834-eadr3834
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W4411299195
- Cited by
- 185
- References
- 54
- FWCI
- 25.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.