Hyperpolarization-activated cyclic nucleotide–gated 2 (HCN2) ion channels drive pain in mouse models of diabetic neuropathy
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Blocking HCN2 ion channel activity in peripheral nociceptive neurons alleviates the pain hypersensitivity associated with diabetic neuropathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Central sensitization: a generator of pain hypersensitivity by central neural plasticity
Latremoliere, A., & Woolf, C. J. (2009) · The Journal of Pain · doi:10.1016/j.jpain.2009.06.012 · Cited by 3,913
Impaired nociception and pain sensation in mice lacking the capsaicin receptor
Caterina, M. J., Leffler, A., Malmberg, A. B., Martin, W. J., Trafton, J., Petersen-Zeitz, K. R., Koltzenburg, M., Basbaum, A. I., & Julius, D. (2000) · Science · doi:10.1126/science.288.5464.306 · Cited by 3,544
Cited by
Chaudhuri, J., Bains, Y., Guha, S., Kahn, A., Hall, D., Bose, N., Gugliucci, A., & Kapahi, P. (2018) · Cell Metabolism · doi:10.1016/j.cmet.2018.08.014 · Cited by 669
Antar, S. A., Ashour, N. A., Sharaky, M., Khattab, M., Ashour, N. A., Zaid, R. T., Roh, E. J., Elkamhawy, A., & Al-Karmalawy, A. A. (2023) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2023.115734 · Cited by 622
Emerging Targets in Type 2 Diabetes and Diabetic Complications
Demir, S., Nawroth, P. P., Herzig, S., & Ekim Üstünel, B. (2021) · Advanced Science · doi:10.1002/advs.202100275 · Cited by 525
Elafros, M. A., Andersen, H., Bennett, D. L., Savelieff, M. G., Viswanathan, V., Callaghan, B. C., & Feldman, E. L. (2022) · The Lancet Neurology · doi:10.1016/s1474-4422(22)00188-0 · Cited by 387
New perspectives in diabetic neuropathy
Eid, S. A., Rumora, A. E., Beirowski, B., Bennett, D. L., Hur, J., Savelieff, M. G., & Feldman, E. L. (2023) · Neuron · doi:10.1016/j.neuron.2023.05.003 · Cited by 257
Shiers, S., Klein, R. M., & Price, T. J. (2020) · Pain · doi:10.1097/j.pain.0000000000001973 · Cited by 232
“This same compound, ivabradine, causes robust analgesia in mouse models of neuropathic pain.(45,46,53) Interestingly, HCN2 shows substantially higher expression in nociceptors and largediameter neurons in mouse (71.”
BackgroundDiabetic neuropathy and neuropathic pain: a (con)fusion of pathogenic mechanisms?
Calcutt, N. A. (2020) · Pain · doi:10.1097/j.pain.0000000000001922 · Cited by 159
“Inhibition of HCNs1-4 or ablation of HCN2 alleviated allodynia to von Frey filaments but not thermal hypoalgesia in diabetic mice.(358) Expression of HCN1-4 protein was not altered in the peripheral nerve of diabeticmice, and it was speculated that a measured increase in intracellular cAMP might activate HCN2 and thus…”
BackgroundSantoro, B., & Shah, M. M. (2020) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010919-023356 · Cited by 108
Griggs, R. B., Santos, D. F., Laird, D. E., Doolen, S., Donahue, R. R., Wessel, C. R., Fu, W., Sinha, G. P., Wang, P., Zhou, J., et al. (2019) · Neurobiology of Disease · doi:10.1016/j.nbd.2019.02.019 · Cited by 37
Harde, E., Hierl, M., Weber, M., Waiz, D., Wyler, R., Wach, J.-Y., Haab, R., Gundlfinger, A., He, W., Schnider, P., et al. (2024) · Cell Chemical Biology · doi:10.1016/j.chembiol.2023.11.004 · Cited by 14
Metadata
- Authors
- Tsantoulas, C., Laínez, S., Wong, S., Mehta, I., Vilar, B., & McNaughton, P. A.
- Venue
- Science Translational Medicine
- Published
- 2017-09-27
- Volume
- 9
- Issue
- 409
- Pages
- eaam6072-eaam6072
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2757842300
- Cited by
- 112
- References
- 2
- FWCI
- 7.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.