Bimodal neuromodulation combining sound and tongue stimulation reduces tinnitus symptoms in a large randomized clinical study
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Noninvasive bimodal neuromodulation reduces tinnitus symptom severity within 12 weeks of treatment for up to 12 months after completing treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Incomplete Multivariate Data
Schafer, J. L. (1997) · doi:10.1201/9781439821862 · Cited by 6,012 · cited 1×
“Missing data were handled by using a Markov chain Monte Carlo multiple imputation method (75, 76) that filled in the missing predictor variables for 10 multiple imputed datasets.”
MethodThe Organization of Behavior; A Neuropsychological Theory.
Attneave, F., B., M., & Hebb, D. O. (1950) · The American Journal of Psychology · doi:10.2307/1418888 · Cited by 5,146
State-Trait Anxiety Inventory for Adults
Spielberger, C. D. (2012) · PsycTESTS Dataset · doi:10.1037/t06496-000 · Cited by 3,479
Pocock, S. J., & Simon, R. (1975) · Biometrics · doi:10.2307/2529712 · Cited by 2,350
Ruxton, G. D. (2006) · Behavioral Ecology · doi:10.1093/beheco/ark016 · Cited by 1,988
The Tinnitus Functional Index: Development of a New Clinical Measure for Chronic, Intrusive Tinnitus
Meikle, M. B., Henry, J. A., Griest, S. E., Stewart, B. J., Abrams, H. B., McArdle, R., Myers, P. J., Newman, C. W., Sandridge, S., Turk, D. C., et al. (2012) · Ear & Hearing · doi:10.1097/aud.0b013e31822f67c0 · Cited by 792
Clinical practice guideline: tinnitus
Tunkel, D. E., Bauer, C. A., Sun, G. H., Rosenfeld, R. M., Chandrasekhar, S. S., Cunningham, E. R., Archer, S. M., Blakley, B. W., Carter, J. M., Granieri, E. C., et al. (2014) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599814545325 · Cited by 769
A systematic review of the reporting of tinnitus prevalence and severity
McCormack, A., Edmondson-Jones, M., Somerset, S., & Hall, D. (2016) · Hearing Research · doi:10.1016/j.heares.2016.05.009 · Cited by 715
Self-citationCognitive behavioural therapy for tinnitus
Martinez-Devesa, P., Perera, R., Theodoulou, M., & Waddell, A. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005233.pub3 · Cited by 477
A multidisciplinary European guideline for tinnitus: diagnostics, assessment, and treatment
Cima, R. F. F., Mazurek, B., Haider, H., Kikidis, D., Lapira, A., Noreña, A., & Hoare, D. J. (2019) · HNO · doi:10.1007/s00106-019-0633-7 · Cited by 442
Cited by
Predictive coding and stochastic resonance as fundamental principles of auditory phantom perception.
Schilling, A., Sedley, W., Gerum, R., Metzner, C., Tziridis, K., Maier, A., Schulze, H., Zeng, F.-G., Friston, K. J., & Krauss, P. (2023) · Brain · doi:10.1093/brain/awad255 · Cited by 70
A State-of-Art Review of Digital Technologies for the Next Generation of Tinnitus Therapeutics
Searchfield, G. D., Sanders, P. J., Doborjeh, Z., Doborjeh, M., Boldu, R., Sun, K., & Barde, A. (2021) · Frontiers in Digital Health · doi:10.3389/fdgth.2021.724370 · Cited by 33
Tong, Z., Deng, W., Huang, X., Dong, H., Li, J., Zhao, F., Chen, G., Zhou, X., Li, H., Lan, L., et al. (2023) · Ear & Hearing · doi:10.1097/aud.0000000000001318 · Cited by 19
Clinical Practice Guideline: Tinnitus Update
Adams, M. E., Cramer, J. D., Tunkel, D. E., Lee, V. S., Bourgeois, J. A., Eshraghi, A. A., Fagelson, M. A., White, K. B., Juliano, A. F., Kim, H., et al. (2026) · Otolaryngology–Head and Neck Surgery · doi:10.1002/ohn.70417 · Cited by 1
Metadata
- Authors
- Conlon, B., Langguth, B., Hamilton, C., Hughes, S., Meade, E., Connor, C. O., Schecklmann, M., Hall, D. A., Vanneste, S., Leong, S. L., Subramaniam, T., D’Arcy, S., & Lim, H. H.
- Venue
- Science Translational Medicine
- Published
- 2020-10-07
- Volume
- 12
- Issue
- 564
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W3092592769
- Cited by
- 114
- References
- 13
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.