CoChat

Variability of Voriconazole Plasma Levels Measured by New High-Performance Liquid Chromatography and Bioassay Methods

Open access
Pascual, Andres, Nieth, Valérie, Calandra, Thierry, Bille, Jacques, Bolay, Saskia, Decosterd, Laurent A., Buclin, Thierry, Majcherczyk, Paul A., Sanglard, Dominique, Marchetti, Oscar · 2007 · Antimicrobial Agents and Chemotherapy
Cited by 96

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Voriconazole (VRC) is a broad-spectrum antifungal triazole with nonlinear pharmacokinetics. The utility of measurement of voriconazole blood levels for optimizing therapy is a matter of debate. Available high-performance liquid chromatography (HPLC) and bioassay methods are technically complex, time-consuming, or have a narrow analytical range. Objectives of the present study were to develop new, simple analytical methods and to assess variability of voriconazole blood levels in patients with invasive mycoses. Acetonitrile precipitation, reverse-phase separation, and UV detection were used for HPLC. A voriconazole-hypersusceptible Candida albicans mutant lacking multidrug efflux transporters ( cdr1 Δ/ cdr1 Δ, cdr2 Δ/ cdr2 Δ, flu1 Δ/ flu1 Δ, and mdr1 Δ/ mdr1 Δ) and calcineurin subunit A ( cna Δ/ cna Δ) was used for bioassay. Mean intra-/interrun accuracies over the VRC concentration range from 0.25 to 16 mg/liter were 93.7% ± 5.0%/96.5% ± 2.4% (HPLC) and 94.9% ± 6.1%/94.7% ± 3.3% (bioassay). Mean intra-/interrun coefficients of variation were 5.2% ± 1.5%/5.4% ± 0.9% and 6.5% ± 2.5%/4.0% ± 1.6% for HPLC and bioassay, respectively. The coefficient of concordance between HPLC and bioassay was 0.96. Sequential measurements in 10 patients with invasive mycoses showed important inter- and intraindividual variations of estimated voriconazole area under the concentration-time curve (AUC): median, 43.9 mg · h/liter (range, 12.9 to 71.1) on the first and 27.4 mg · h/liter (range, 2.9 to 93.1) on the last day of therapy. During therapy, AUC decreased in five patients, increased in three, and remained unchanged in two. A toxic encephalopathy probably related to the increase of the VRC AUC (from 71.1 to 93.1 mg · h/liter) was observed. The VRC AUC decreased (from 12.9 to 2.9 mg · h/liter) in a patient with persistent signs of invasive aspergillosis. These preliminary observations suggest that voriconazole over- or underexposure resulting from variability of blood levels might have clinical implications. Simple HPLC and bioassay methods offer new tools for monitoring voriconazole therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/aac.00957-06

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Pascual, A., Nieth, V., Calandra, T., Bille, J., Bolay, S., Decosterd, L. A., Buclin, T., Majcherczyk, P. A., Sanglard, D., & Marchetti, O.
Venue
Antimicrobial Agents and Chemotherapy
Published
2007-01
Volume
51
Issue
1
Pages
137-143
ISSN
  • 0066-4804 (ISSN-L)
  • 1098-6596
OpenAlex
W2147972349
Cited by
96
References
11
FWCI
4.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.