Effect of impact stress on microbial recovery on an agar surface
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Microbial stress due to the impaction of microorganisms onto an agar collection surface was studied experimentally. The relative recovery rates of aerosolized Pseudomonas fluorescens and Micrococcus luteus were determined as a function of the impaction velocity by using a moving agar slide impactor operating over a flow rate range from 3.8 to 40 liters/min yielding impaction velocities from 24 to 250 m/s. As a reference, the sixth stage of the Andersen Six-Stage Viable Particle Sizing Sampler was used at its operating flow rate of 28.3 liters/min (24 m/s). At a collection efficiency of close to 100% for the agar slide impactor, an increase in sampling flow rate and, therefore, in impaction velocity produced a significant decline in the percentage of microorganisms recovered. Conversely, when the collection efficiency was less than 100%, greater recovery and lower injury rates occurred. The highest relative rate of recovery (approximately 51% for P. fluorescens and approximately 62% for M. luteus) was obtained on the complete (Trypticase soy agar) medium at 40 and 24 m/s (6.4 and 3.8 liters/min), respectively. M. luteus demonstrated less damage than P. fluorescens, suggesting the hardy nature of the gram-positive strain versus that of the gram-negative microorganism. Comparison of results from the agar slide and Andersen impactors at the same sampling velocity showed that recovery and injury due to collection depends not only on the magnitude of the impaction velocity but also on the degree to which the microorganisms may be embedded in the collection medium.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol Measurement: Principles, Techniques, and Applications
(2011) · Wiley eBooks · doi:10.1002/9781118001684 · Cited by 1,352
AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932 · cited 1×
“Examples of infections which may result from the presence of microorganisms in the air are tuberculosis (54), measles (53), legionellosis (10), and histoplasmosis (3).”
BackgroundPhysiology of the bacterial cell : a molecular approach
Neidhardt, F. C., Ingraham, J. L., & Schaechter, M. (1990) · Cited by 808
Riley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313 · cited 1×
“Examples of infections which may result from the presence of microorganisms in the air are tuberculosis (54), measles (53), legionellosis (10), and histoplasmosis (3).”
BackgroundKLOOS, W. E., TORNABENE, T. G., & SCHLEIFER, K. H. (1974) · International Journal of Systematic Bacteriology · doi:10.1099/00207713-24-1-79 · Cited by 310
Bioaerosols: Prevalence and health effects in the indoor environment
Burger, H. (1990) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(05)80170-8 · Cited by 280 · cited 1×
“Airborne microorganisms in indoor ( 2 , 3, 44) and outdoor (29, 62) environments, from either natural (48, 63) or industrial (4) sources, may produce ill effects on humans ranging from mild irritation to disease.”
BackgroundPositive-Hole Correction of Multiple-Jet Impactors for Collecting Viable Microorganisms
MACHER, J. M. (1989) · American Industrial Hygiene Association Journal · doi:10.1080/15298668991375164 · Cited by 256 · cited 2×
“was used for the determination of the Andersen results (31).”
MethodEVALUATION OF EIGHT BIOAEROSOL SAMPLERS CHALLENGED WITH AEROSOLS OF FREE BACTERIA
Jensen, P. A., Todd, W. F., Davis, G. N., & Scarpino, P. V. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360319 · Cited by 212
Performance of bioaerosol samplers: collection characteristics and sampler design considerations
Nevalainen, A. I., Pastuszka, J. S., Liebhaber, F. B., & Willeke, K. (1992) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(92)90166-i · Cited by 184 · cited 1×
“a liquid instead of a solid agar surface (18, 45).”
BackgroundSelf-citationZoBell, C. E. (1946) · Biodiversity Heritage Library (Smithsonian Institution) · doi:10.5962/bhl.title.10079 · Cited by 165
Cited by
Primary biological aerosol particles in the atmosphere: a review
Després, V. R., Huffman, J. A., Burrows, S. M., Hoose, C., Safatov, A. S., Buryak, G., Fröhlich-Nowoisky, J., Elbert, W., Andreae, M. O., Pöschl, U., et al. (2012) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v64i0.15598 · Cited by 1,500
“, 1997) and bacteria can be easily damaged when impacted via traditional sampling devices (Stewart et al., 1995).”
BackgroundInfluentialAtmospheric Movement of Microorganisms in Clouds of Desert Dust and Implications for Human Health
Griffin, D. W. (2007) · Clinical Microbiology Reviews · doi:10.1128/cmr.00039-06 · Cited by 795
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Burrows, S. M., Elbert, W., Lawrence, M. G., & Pöschl, U. (2009) · Atmospheric Chemistry and Physics · doi:10.5194/acp-9-9263-2009 · Cited by 564
Size‐resolved emission rates of airborne bacteria and fungi in an occupied classroom
Qian, J., Hospodsky, D., Yamamoto, N., Nazaroff, W. W., & Peccia, J. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00769.x · Cited by 395
The index of microbial air contamination
Pasquarella, C., Pitzurra, O., & Savino, A. (2000) · Journal of Hospital Infection · doi:10.1053/jhin.2000.0820 · Cited by 380
Bioaerosol sampling: Classical approaches, advances, and perspectives
Mainelis, G. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1671950 · Cited by 229
“In addition, impaction subjects airborne microorganisms to sudden deceleration and that damages them, including the loss of culturability (Stewart et al. 1995; Wang et al. 2001) and even membrane integrity (Zhen et al. 2013) thus further reducing the fraction of culturable microorganisms that can…”
BackgroundTerzieva, S., Donnelly, J., Ulevicius, V, Grinshpun, S. A., Willeke, K., Stelma, G. N., & Brenner, K. P. (1996) · Applied and Environmental Microbiology · doi:10.1128/aem.62.7.2264-2272.1996 · Cited by 220
Self-citationPeccia, J., & Hernandez, M. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.02.029 · Cited by 208
“Further, conventional collection devices that harvest particulate matter from air introduce significant sampling stresses, which can substantially reduce the viability and/or culturability of a broad range of airborne microorganisms (Buttner et al., 1997; Stewart et al., 1995).”
Real-time measurement of fluorescence spectra from single airborne biological particles
Hill, S. C., Pinnick, R. G., Niles, S., Pan, Y.-L., Holler, S., Chang, R. K., Bottiger, J., Chen, B. T., Orr, C.-S., & Feather, G. (1999) · Field Analytical Chemistry & Technology · doi:10.1002/(sici)1520-6521(1999)3:4/5<221::aid-fact2>3.0.co;2-7 · Cited by 205
Dust‐borne bacteria in animal sheds, schools and children's day care centres
Andersson, A. M., Weiss, N., Rainey, F., & Salkinoja‐Salonen, M. S. (1999) · Journal of Applied Microbiology · doi:10.1046/j.1365-2672.1999.00706.x · Cited by 164
“Choice of the method used for sampling bioaerosols will affect both the number of viable organisms and the species composition obtained by cultivation (Marthi 1994; Stewart et al. 1995) because air-borne and dehydrated bacteria are sublethally injured.”
MethodReview / SynthèseBioaerosols from municipal and animal wastes: background and contemporary issues
Pillai, S. D., & Ricke, S. C. (2002) · Canadian Journal of Microbiology · doi:10.1139/w02-070 · Cited by 164
“This method of sample collection is meant to overcome some of the physical damage that cells encounter when they are exposed to impinger- and impactorbased sampling (Stewart et al. 1995).”
MethodSurvival of Airborne Microorganisms During Swirling Aerosol Collection
Lin, X., Reponen, T., Willeke, K., Wang, Z., Grinshpun, S. A., & Trunov, M. (2000) · Aerosol Science and Technology · doi:10.1080/027868200303722 · Cited by 163
“The samplers were evaluated in the same laboratory facility that had been developed and used for previous bioaerosol sampler (evaluations Stewart et al. 1995; Grinshpun )et al. 1997; Lin et al. 1997 .”
BackgroundMethodSelf-citation
Metadata
- Authors
- Stewart, S. L., Grinshpun, S. A., Willeke, K., Terzieva, S., Ulevicius, V, & Donnelly, J.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1995-04
- Volume
- 61
- Issue
- 4
- Pages
- 1232-1239
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W2108699911
- Cited by
- 237
- References
- 29
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.