The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Full-scale studies of factors related to coliform regrowth in drinking water
Open accessAbstract
An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence. The study concludes that the occurrence of coliform bacteria within a distribution system is dependent upon a complex interaction of chemical, physical, operational, and engineering parameters. No one factor could account for all of the coliform occurrences, and one must consider all of the parameters described above in devising a solution to the regrowth problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inactivation of biofilm bacteria
LeChevallier, M. W., Cawthon, C. D., & Lee, R. G. (1988) · Applied and Environmental Microbiology · doi:10.1128/aem.54.10.2492-2499.1988 · Cited by 576
Self-citationDirect measurement of chlorine penetration into biofilms during disinfection
De Beer, D., Srinivasan, R., & Stewart, P. S. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.12.4339-4344.1994 · Cited by 521
Factors promoting survival of bacteria in chlorinated water supplies
LeChevallier, M. W., Cawthon, C. D., & Lee, R. G. (1988) · Applied and Environmental Microbiology · doi:10.1128/aem.54.3.649-654.1988 · Cited by 452
Self-citationBacterial nutrients in drinking water
LeChevallier, M. W., Schulz, W., & Lee, R. G. (1991) · Applied and Environmental Microbiology · doi:10.1128/aem.57.3.857-862.1991 · Cited by 330
Self-citationColiform Regrowth in Drinking Water: A Review
LeChevallier, M. W. (1990) · Journal AWWA · doi:10.1002/j.1551-8833.1990.tb07054.x · Cited by 262
Self-citationDisinfecting Biofilms in a Model Distribution System
LeChevallier, M. W., Lowry, C. D., & Lee, R. G. (1990) · Journal AWWA · doi:10.1002/j.1551-8833.1990.tb06996.x · Cited by 250
Self-citationBiological Processes in Drinking Water Treatment
Bouwer, E. J., & Crowe, P. B. (1988) · Journal AWWA · doi:10.1002/j.1551-8833.1988.tb03103.x · Cited by 215
Evaluating the Performance of Biologically Active Rapid Filters
LeChevallier, M. W., Becker, W. C., Schorr, P., & Lee, R. G. (1992) · Journal AWWA · doi:10.1002/j.1551-8833.1992.tb07339.x · Cited by 178
Self-citationBiological treatment of public water supplies
Rittmann, B. E., Huck, P. M., & Bouwer, E. J. (1989) · Critical Reviews in Environmental Control · doi:10.1080/10643388909388362 · Cited by 120
Enumeration, Occurrence, and Significance of Injured Indicator Bacteria in Drinking Water
McFeters, G. A. (1990) · Brock/Springer series in contemporary bioscience · doi:10.1007/978-1-4612-4464-6_23 · Cited by 96
Cited by
Microbial ecology of drinking water distribution systems
Berry, D., Xi, C., & Raskin, L. (2006) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2006.05.007 · Cited by 453
Deficiencies in drinking water distribution systems in developing countries
Lee, E. J., & Schwab, K. J. (2005) · Journal of Water and Health · doi:10.2166/wh.2005.0012 · Cited by 364
Intermittent Water Supply: Prevalence, Practice, and Microbial Water Quality
Kumpel, E., & Nelson, K. L. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.5b03973 · Cited by 294
Comparing microbial water quality in an intermittent and continuous piped water supply
Kumpel, E., & Nelson, K. L. (2013) · Water Research · doi:10.1016/j.watres.2013.05.058 · Cited by 226
Metadata
- Authors
- LeChevallier, M. W., Welch, N. J., & Smith, D. B.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1996-07
- Volume
- 62
- Issue
- 7
- Pages
- 2201-2211
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W2168640592
- Cited by
- 484
- References
- 13
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Full-scale studies of factors related to coliform regrowth in drinking water. https://app.cochat.ai/papers/10.1128/aem.62.7.2201-2211.1996
- The paper
- LeChevallier, M. W., Welch, N. J., & Smith, D. B. (1996). Full-scale studies of factors related to coliform regrowth in drinking water. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.62.7.2201-2211.1996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.