Cell Surface Analysis Techniques: What Do Cell Preparation Protocols Do to Cell Surface Properties?
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Cell surface analysis often requires manipulation of cells prior to examination. The most commonly employed procedures are centrifugation at different speeds, changes of media during washing or final resuspension, desiccation (either air drying for contact angle measurements or freeze-drying for sensitive spectroscopic analysis, such as X-ray photoelectron spectroscopy), and contact with hydrocarbon (hydrophobicity assays). The effects of these procedures on electrophoretic mobility, adhesion to solid substrata, affinity to a number of Sepharose columns, structural integrity, and cell viability were systematically investigated for a range of model organisms, including carbon- and nitrogen-limited Psychrobacter sp. strain SW8 (glycocalyx-bearing cells), Escherichia coli (gram-negative cells without a glycocalyx), and Staphylococcus epidermidis (gram-positive cells without a glycocalyx). All of the cell manipulation procedures severely modified the physicochemical properties of cells, but with each procedure some organisms were more susceptible than others. Considerable disruption of cell surfaces occurred when organisms were placed in contact with a hydrocarbon (hexadecane). The majority of cells became nonculturable after air drying and freeze-drying. Centrifugation at a high speed (15,000 × g ) modified many cell surface parameters significantly, although cell viability was considerably affected only in E. coli . The type of washing or resuspension medium had a strong influence on the values of cell surface parameters, particularly when high-salt solutions were compared with low-salt buffers. The values for parameters obtained with different methods that allegedly measure similar cell surface properties did not correlate for most cells. These results demonstrate that the methods used to prepare cells for cell surface analysis need to be critically investigated for each microorganism so that the final results obtained reflect the nature of the in situ microbial cell surface as closely as possible. There is an urgent need for new, reliable, nondestructive, minimally manipulative cell surface analysis techniques that can be used in situ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of colloid and surface chemistry
Hiemenz, P. C., & Rajagopalan, R. (1977) · Cited by 3,500
Adherence of bacteria to hydrocarbons: A simple method for measuring cell-surface hydrophobicity
Rosenberg, M. (1980) · FEMS Microbiology Letters · doi:10.1016/0378-1097(80)90106-8 · Cited by 2,331
Introduction to Colloid and Surface Chemistry
(1992) · Elsevier eBooks · doi:10.1016/c2009-0-24070-0 · Cited by 1,856
Trehalose and sucrose protect both membranes and proteins in intact bacteria during drying
Leslie, S. B., Israeli, E., Lighthart, B., Crowe, J. H., & Crowe, L. M. (1995) · Applied and Environmental Microbiology · doi:10.1128/aem.61.10.3592-3597.1995 · Cited by 977 · cited 1×
“The cytoplasmic membrane is considered the main site of dehydration damage due to changes in the physical state of membrane lipids and/or modification of the structure of key proteins (29, 31).”
BackgroundSurface thermodynamics of bacterial adhesion
Absolom, D. R., Lamberti, F. V., Policova, Z., Zingg, W., van Oss, C. J., & Neumann, A. W. (1983) · Applied and Environmental Microbiology · doi:10.1128/aem.46.1.90-97.1983 · Cited by 723 · cited 2×
“Sepharose gel networks themselves (1), unsubstituted gels are used as controls.”
BackgroundMethodMeasurement of the surface free energy of bacterial cell surfaces and its relevance for adhesion
Busscher, H. J., Weerkamp, A. H., van der Mei, H. C., van Pelt, A. W., de Jong, H. P., & Arends, J. (1984) · Applied and Environmental Microbiology · doi:10.1128/aem.48.5.980-983.1984 · Cited by 721 · cited 3×
“0 for bacterial filter cake preparation (5) and to 0.”
BackgroundMethodBiomolecular Imaging with the Atomic Force Microscope
Hansma, H. G., & Hoh, J. H. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.000555 · Cited by 539 · cited 1×
“Flow cytometry (37) and atomic force microscopy in the tapping mode in situ (21) in combination with appropriate cell surface markers or appropriately modified cantilever tips may permit nondestructive and noninvasive analysis of cell surface parameters.”
Background(1984) · Springer eBooks · doi:10.1007/978-3-642-70137-5 · Cited by 448
Kennedy, J. F., & Shimizu, J. (1996) · Carbohydrate Polymers · doi:10.1016/0144-8617(96)82557-4 · Cited by 444
Bacterial adherence to hydrocarbons: a useful technique for studying cell surface hydrophobicity
Rosenberg, M. (1984) · FEMS Microbiology Letters · doi:10.1016/0378-1097(84)90026-0 · Cited by 436
Cited by
Bacterial cell attachment, the beginning of a biofilm
Palmer, J., Flint, S., & Brooks, J. (2007) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-007-0234-4 · Cited by 755
Quantification of bacterial adhesion forces using atomic force microscopy (AFM)
Fang, H. H. P., Chan, K.-Y., & Xu, L.-C. (2000) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(99)00137-2 · Cited by 261
Gill, A. O., & Holley, R. A. (2006) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2006.04.046 · Cited by 225
Transport and straining of E. coli O157:H7 in saturated porous media
Bradford, S. A., Simunek, J., & Walker, S. L. (2006) · Water Resources Research · doi:10.1029/2005wr004805 · Cited by 213
“The hydrophobicity of E. coli O157:H7 was quantified by using the microbial adhesion to hydrocarbons (MATH) test [Pembrey et al., 1999].”
MethodInfluence of Growth Phase on Adhesion Kinetics of Escherichia coli D21g
Walker, S. L., Hill, J. E., Redman, J. A., & Elimelech, M. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.6.3093-3099.2005 · Cited by 190
“percentages of total cells partitioned into the hydrocarbon (52).”
BackgroundMethodBacterial Cell Surface Damage Due to Centrifugal Compaction
Peterson, B. W., Sharma, P. K., van der Mei, H. C., & Busscher, H. J. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.06780-11 · Cited by 168
“In general, harvesting by the high-speed centrifugation (15,000 g) of bacterial cultures was found to reduce the surface charge of organisms not protected by a dense layer of extracellular polymeric substances (9).”
BackgroundBernstein, R., Belfer, S., & Freger, V. (2011) · Environmental Science & Technology · doi:10.1021/es1043694 · Cited by 161
Survival Rate of Microbes after Freeze-Drying and Long-Term Storage
Miyamoto-Shinohara, Y., Imaizumi, T., Sukenobe, J., Murakami, Y., Kawamura, S., & Komatsu, Y. (2000) · Cryobiology · doi:10.1006/cryo.2000.2282 · Cited by 158
Metadata
- Authors
- Pembrey, R. S., Marshall, K. C., & Schneider, R. P.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1999-07
- Volume
- 65
- Issue
- 7
- Pages
- 2877-2894
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W2150205450
- Cited by
- 241
- References
- 49
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.