Use of adhesion-defective mutants of Staphylococcus aureus to define the role of specific plasma proteins in promoting bacterial adhesion to canine arteriovenous shunts
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
We used an ex vivo canine arteriovenous shunt model, previously developed to study plasma protein adsorption and thrombogenesis on polymeric biomaterials, to define the role of host proteins in promoting adhesion of Staphylococcus aureus. Either polyethylene or polyvinyl chloride tubings were exposed to canine blood for 5, 15, or 60 min at a flow rate of 300 ml/min and then were flushed in phosphate-buffered saline (PBS), cut into 1.5-cm segments, and stored at -70 degrees C. After thawing, each segment was preincubated in 0.5% albumin in PBS to prevent nonspecific staphylococcal attachment to surfaces that were not exposed to blood. Each segment was then incubated with 4 x 10(6) CFU of [3H]thymidine-labelled S. aureus per ml for 60 min at 37 degrees C in an in vitro adhesion assay. Two site-specific mutants of S. aureus were tested: one specifically defective in adhesion to surface-bound fibronectin (FnAd-def) and the other defective in adhesion to fibrinogen (FgAD-def) [corrected]. Compared with their respective parental strains, the FgAd-def, but not the FnAd-def, mutant of S. aureus showed a strong (> 80%) decrease in attachment to ex vivo tubings. The adhesion of each strain of S. aureus onto polyethylene was consistently more than twofold higher than the adhesion onto polyvinyl chloride segments exposed to flowing blood for 5 or 15 min, but adhesion became similar to that on polyvinyl chloride after 60 min of exposure. In conclusion, the specific adhesion-defective mutants of S. aureus suggested that fibrinogen was the most active adhesion-promoting protein in a short-term blood-material interaction. The experimental approach described in this study should prove useful for screening materials thought to be resistant to protein-mediated staphylococcal adhesion and colonization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular characterization of the clumping factor (fibrinogen receptor) of Staphylococcus aureus
McDevitt, D., Francois, P., Vaudaux, P., & Foster, T. J. (1994) · Molecular Microbiology · doi:10.1111/j.1365-2958.1994.tb00304.x · Cited by 546 · cited 12×
“aureus 8325-4, which contains a multicopy plasmid leading to overexpression of clumping factor, whose molecular and functional properties have been previously described in detail (21).”
BackgroundMethodResultInfluentialSelf-citation[46] Fibronectin: Purification, immunochemical properties, and biological activities
Ruoslahti, E., Hayman, E. G., Pierschbacher, M., & Engvall, E. (1982) · Methods in Enzymology · doi:10.1016/0076-6879(82)82103-4 · Cited by 533
Herrmann, M., Vaudaux, P. E., Pittet, D., Auckenthaler, R., Lew, P. D., Perdreau, F. S., Peters, G., & Waldvogel, F. A. (1988) · The Journal of Infectious Diseases · doi:10.1093/infdis/158.4.693 · Cited by 522
Self-citationThe Relationship Between the Thrombotic and Infectious Complications of Central Venous Catheters
Raad, I. I. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03510370066034 · Cited by 493 · cited 1×
“A relationship between catheter-related thrombogenesis and infection has been proposed at both the subclinical microscopic level (29, 35, 36) and the clinical level, as recently demonstrated with central venous catheters used in cancer patients (32).”
BackgroundCurrent Clinical Topics in Infectious Diseases
(1984) · Archives of Internal Medicine · doi:10.1001/archinte.1984.00350150042013 · Cited by 471
JÖNSSON, K., SIGNÄS, C., MÜLLER, H., & LINDBERG, M. (1991) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1991.tb16468.x · Cited by 365
Patti, J. M., Bremell, T., Krajewska-Pietrasik, D., Abdelnour, A., Tarkowski, A., Rydén, C., & Höök, M. (1994) · Infection and Immunity · doi:10.1128/iai.62.1.152-161.1994 · Cited by 357 · cited 3×
“Further studies and a greater range of experimental conditions and materials are required to precisely evaluate the contribution of fibronectin and additional plasma or platelet components, such as vitronectin (1, 18), thrombospondin (11), or collagen (26, 27), to S.”
BackgroundPatti, J. M., Jonsson, H., Guss, B., Switalski, L. M., Wiberg, K., Lindberg, M., & Höök, M. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)42898-0 · Cited by 282
Presence of Laminin Receptors in Staphylococcus aureus
Lopes, J. D., dos Reis, M., & Brentani, R. R. (1985) · Science · doi:10.1126/science.3160113 · Cited by 269
Cloning and expression of the gene for a fibronectin-binding protein from Staphylococcus aureus.
Flock, J. I., Fröman, G., Jönsson, K., Guss, B., Signäs, C., Nilsson, B., Raucci, G., Höök, M., Wadström, T., & Lindberg, M. (1987) · The EMBO Journal · doi:10.1002/j.1460-2075.1987.tb02511.x · Cited by 257 · cited 1×
“These studies allowed characterization of the genes for the fibrinogen-binding protein (clumping factor [21]), a collagen adhesin (26, 27), and two distinct but related fibronectin-binding proteins (7, 14).”
BackgroundVaudaux, P., Pittet, D., Haeberli, A., Huggler, E., Nydegger, U. E., Lew, D. P., & Waldvogel, F. A. (1989) · Journal of Infectious Diseases · doi:10.1093/infdis/160.5.865 · Cited by 234
Self-citationChhatwal, G. S., Preissner, K. T., Müller-Berghaus, G., & Blobel, H. (1987) · Infection and Immunity · doi:10.1128/iai.55.8.1878-1883.1987 · Cited by 212 · cited 1×
“aureus attachment to polymeric surfaces is strongly promoted by selectively adsorbed plasma or extracellular matrix proteins such as fibrinogen (2, 10, 12, 21), fibronectin (12, 34, 35, 38–42), collagen (13, 26, 27, 42), vitronectin (3, 18, 28), laminin (12, 19, 42), and thrombospondin (11).”
BackgroundThrombospondin binds to Staphylococcus aureus and promotes staphylococcal adherence to surfaces
Herrmann, M., Suchard, S. J., Boxer, L. A., Waldvogel, F. A., & Lew, P. D. (1991) · Infection and Immunity · doi:10.1128/iai.59.1.279-288.1991 · Cited by 195 · cited 2×
“Further studies and a greater range of experimental conditions and materials are required to precisely evaluate the contribution of fibronectin and additional plasma or platelet components, such as vitronectin (1, 18), thrombospondin (11), or collagen (26, 27), to S.”
BackgroundKuypers, J. M., & Proctor, R. A. (1989) · Infection and Immunity · doi:10.1128/iai.57.8.2306-2312.1989 · Cited by 192
Self-citationVercellotti, G. M., McCarthy, J. B., Lindholm, P., Peterson, P. K., Jacob, H. S., & Furcht, L. T. (1985) · PubMed Central · Cited by 190
Properties and biological inteactions of polyurethane anionomers: Effect of sulfonate incorporation
Grasel, T. G., & Cooper, S. L. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230304 · Cited by 179
Self-citationVaudaux, P. E., Waldvogel, F. A., Morgenthaler, J. ‐., & Nydegger, U. E. (1984) · Infection and Immunity · doi:10.1128/iai.45.3.768-774.1984 · Cited by 157 · cited 14×
“125 to 1 mg/ml) of fibronectin, followed by rinsing in PBS (36, 39).”
MethodInfluentialSelf-citationForeign Body Infection: Role of Fibronectin as a Ligand for the Adherence of Staphylococcus aureus
Vaudaux, P. E., Suzuki, R., Waldvogel, F. A., Morgenthaler, J. ‐., & Nydegger, U. E. (1984) · The Journal of Infectious Diseases · doi:10.1093/infdis/150.4.546 · Cited by 157
Self-citationVaudaux, P. E., Pittet, D., Haeberli, A., Lerch, P. G., Morgenthaler, J. ‐., Proctor, R. A., Waldvogel, F. A., & Lew, D. P. (1993) · The Journal of Infectious Diseases · doi:10.1093/infdis/167.3.633 · Cited by 142 · cited 16×
“125 to 1 mg/ml) of fibronectin, followed by rinsing in PBS (36, 39).”
BackgroundMethodResultInfluentialSelf-citationHerrmann, M., Lai, Q. J., Albrecht, R. M., Mosher, D. F., & Proctor, R. A. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/167.2.312 · Cited by 142
Self-citationBale, M., Wohlfahrt, L., Mosher, D., Tomasini, B., & Sutton, R. (1989) · Blood · doi:10.1182/blood.v74.8.2698.2698 · Cited by 126 · cited 1×
“Further studies and a greater range of experimental conditions and materials are required to precisely evaluate the contribution of fibronectin and additional plasma or platelet components, such as vitronectin (1, 18), thrombospondin (11), or collagen (26, 27), to S.”
BackgroundInfections Associated with intravascular lines
Maki, D. (1982) · Medical Entomology and Zoology · Cited by 118
Genetic evidence that bound coagulase of Staphylococcus aureus is not clumping factor
McDevitt, D., Vaudaux, P., & Foster, T. J. (1992) · Infection and Immunity · doi:10.1128/iai.60.4.1514-1523.1992 · Cited by 113 · cited 3×
“Albumin-coated and gelatin-coated PMMA coverslips were used as controls of adhesion to fibrinogen- and fibronectin-coated surfaces, respectively (21, 22, 39).”
MethodSelf-citationThe Role of Fibrinogen in Staphylococcal Adherence to Catheters In Vitro
Cheung, A. L., & Fischetti, V. A. (1990) · Journal of Infectious Diseases · doi:10.1093/infdis/161.6.1177 · Cited by 112 · cited 1×
“aureus attachment to polymeric surfaces is strongly promoted by selectively adsorbed plasma or extracellular matrix proteins such as fibrinogen (2, 10, 12, 21), fibronectin (12, 34, 35, 38–42), collagen (13, 26, 27, 42), vitronectin (3, 18, 28), laminin (12, 19, 42), and thrombospondin (11).”
BackgroundPark, K., Mosher, D. F., & Cooper, S. L. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200506 · Cited by 105 · cited 2×
“More detailed studies demonstrated that the thrombogenicity of a surface was determined by the composition of the initial protein layer rather than the total concentration of protein on the polymer surfaces (25).”
BackgroundMethodSelf-citationA canine ex vivo series shunt for evaluating thrombus deposition on polymer surfaces
Lelah, M. D., Lambrecht, L. K., & Cooper, S. L. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180503 · Cited by 86 · cited 6×
“aureus adhesion to blood-exposed PE tubing occurs at the same time points (5 and 15 min) as that of platelet deposition and activation (6, 17).”
BackgroundMethodInfluentialSelf-citationPhillips, D. R., Fitzgerald, L. A., Chard, I. F., & Parise, L. V. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb30994.x · Cited by 81
Staphylococcus epidermidis Adhesion to Hydrophobic Biomedical Polymer Is Mediated by Platelets
Wang, I.-W., Anderson, J. M., & Marchant, R. E. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/167.2.329 · Cited by 78 · cited 1×
“Colonization of cardiovascular biomaterials is thought to occur on plasma proteins and/or platelets (10, 43) that have been adsorbed on the artificial surfaces shortly after their implantation.”
BackgroundEffect of fibronectin on adherence of Staphylococcus aureus to fibrin thrombi in vitro
Toy, P. T. C. Y., Lai, L. W., Drake, T. A., & van de Sande, M. A. J. (1985) · Infection and Immunity · doi:10.1128/iai.48.1.83-86.1985 · Cited by 76
Lambrecht, L. K., Young, B. R., Stafford, R. E., Park, K., Albrecht, R. M., Mosher, D. F., & Cooper, S. L. (1986) · Thrombosis Research · doi:10.1016/0049-3848(86)90283-5 · Cited by 61
Self-citationCollagen binding in clinical isolates of Staphylococcus aureus
Holderbaum, D. F., Spech, T. J., Ehrhart, L. A., Keys, T. F., & Hall, G. S. (1987) · Journal of Clinical Microbiology · doi:10.1128/jcm.25.12.2258-2261.1987 · Cited by 59 · cited 1×
“aureus attachment to polymeric surfaces is strongly promoted by selectively adsorbed plasma or extracellular matrix proteins such as fibrinogen (2, 10, 12, 21), fibronectin (12, 34, 35, 38–42), collagen (13, 26, 27, 42), vitronectin (3, 18, 28), laminin (12, 19, 42), and thrombospondin (11).”
BackgroundVaudaux, P. E., Yasuda, H., Velazco, M. I., Huggler, E., Ratti, I., Waldvogel, F. A., Lew, D. P., & Proctor, R. A. (1990) · Journal of Biomaterials Applications · doi:10.1177/088532829000500204 · Cited by 58
Self-citationMultiple interactions between human vitronectin and Staphylococcus aureus
Liang, O. D., Maccarana, M., Flock, J., Paulsson, M., Preissner, K. T., & Wadström, T. (1993) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/0925-4439(93)90122-h · Cited by 48 · cited 2×
“Further studies and a greater range of experimental conditions and materials are required to precisely evaluate the contribution of fibronectin and additional plasma or platelet components, such as vitronectin (1, 18), thrombospondin (11), or collagen (26, 27), to S.”
BackgroundCollins, W. E., Mosher, D. F., Tomasini-Johansson, B. R., & Cooper, S. L. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb33049.x · Cited by 30 · cited 3×
“Previous reports have demonstrated that plasma protein and platelet coating of biomaterials is a dynamic process involving selective adsorption and then release of various components (5, 6, 17, 23, 24).”
BackgroundMethodSelf-citationMethods of Assessment of Thrombosis ex Vivoa
Cooper, S. L., FABRIZIUS, D. J., & Grasel, T. G. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb33074.x · Cited by 12 · cited 4×
“can influence thrombus and embolus formation within the first hours of blood-material interaction (6).”
BackgroundInfluentialSelf-citation
Cited by
Bacterial biofilms: from the Natural environment to infectious diseases
Hall-Stoodley, L., Costerton, J. W., & Stoodley, P. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro821 · Cited by 7,143
Götz, F. (2002) · Molecular Microbiology · doi:10.1046/j.1365-2958.2002.02827.x · Cited by 1,178
What drives bacteria to produce a biofilm?
Jefferson, K. K. (2004) · FEMS Microbiology Letters · doi:10.1016/j.femsle.2004.06.005 · Cited by 1,059
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Surface protein adhesins of Staphylococcus aureus
Foster, T. J., & Höök, M. (1998) · Trends in Microbiology · doi:10.1016/s0966-842x(98)01400-0 · Cited by 986
Self-citation
Metadata
- Authors
- Vaudaux, P. E., François, P., Proctor, R. A., McDevitt, D., Foster, T. J., Albrecht, R. M., Lew, D. P., Wabers, H., & Cooper, S. L.
- Venue
- Infection and Immunity
- Publisher
- American Society for Microbiology
- Published
- 1995-02
- Volume
- 63
- Issue
- 2
- Pages
- 585-590
- ISSN
- 0019-9567 (ISSN-L)
- 1098-5522
- OpenAlex
- W2136572457
- Cited by
- 183
- References
- 35
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.