Aminoglycosides Are Captured from both Periplasm and Cytoplasm by the AcrD Multidrug Efflux Transporter of Escherichia coli
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
To understand better the mechanisms of resistance-nodulation-division (RND)-type multidrug efflux pumps, we examined the Escherichia coli AcrD pump, whose typical substrates, aminoglycosides, are not expected to diffuse spontaneously across the lipid bilayer. The hexahistidine-tagged AcrD protein was purified and reconstituted into unilamellar proteoliposomes. Its activity was measured by the proton flux accompanying substrate transport. When the interior of the proteoliposomes was acidified, the addition of aminoglycosides to the external medium stimulated proton efflux and the intravesicular accumulation of radiolabeled gentamicin, suggesting that aminoglycosides can be captured and transported from the external medium in this system (corresponding to cytosol). This activity required the presence of AcrA within the proteoliposomes. Interestingly, the increase in proton efflux also occurred when aminoglycosides were present only in the intravesicular space. This result suggested that AcrD can also capture aminoglycosides from the periplasm to extrude them into the medium in intact cells, acting as a “periplasmic vacuum cleaner.”
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antibiotic Resistance Caused by Gram‐Negative Multidrug Efflux Pumps
Nikaido, H. (1998) · Clinical Infectious Diseases · doi:10.1086/514920 · Cited by 348
Self-citationpH gradients across phospholipid membranes caused by fast flip-flop of un-ionized fatty acids.
Kamp, F., & Hamilton, J. A. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.23.11367 · Cited by 299
Nikaido, H., Basina, M., Nguyen, V., & Rosenberg, E. Y. (1998) · Journal of Bacteriology · doi:10.1128/jb.180.17.4686-4692.1998 · Cited by 224
Self-citation
Cited by
Multidrug Resistance in Bacteria
Nikaido, H. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.78.082907.145923 · Cited by 1,682
Self-citationThe Challenge of Efflux-Mediated Antibiotic Resistance in Gram-Negative Bacteria
Li, X.-Z., Plésiat, P., & Nikaido, H. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00117-14 · Cited by 1,614
Self-citationMultidrug-resistance efflux pumps ? not just for resistance
Piddock, L. J. V. (2006) · Nature Reviews Microbiology · doi:10.1038/nrmicro1464 · Cited by 1,522
Clinically Relevant Chromosomally Encoded Multidrug Resistance Efflux Pumps in Bacteria
Piddock, L. J. V. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.2.382-402.2006 · Cited by 1,231
Efflux-Mediated Drug Resistance in Bacteria: An Update
Li, X.-Z., & Nikaido, H. (2009) · Drugs · doi:10.2165/11317030-000000000-00000 · Cited by 966
Self-citation
Metadata
- Authors
- Aires, J. R., & Nikaido, H.
- Venue
- Journal of Bacteriology
- Publisher
- American Society for Microbiology
- Published
- 2005-03-15
- Volume
- 187
- Issue
- 6
- Pages
- 1923-1929
- ISSN
- 0021-9193 (ISSN-L)
- 1098-5530
- OpenAlex
- W2113156278
- Cited by
- 204
- References
- 3
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.